메뉴 건너뛰기




Volumn 42, Issue 5, 2006, Pages 328-332

Internal reduction established by occiput-C2 pedicle polyaxial screw stabilization in pediatric atlantoaxial rotatory fixation

Author keywords

Atlantoaxial subluxation; Craniocervical instability; Griesel's syndrome; Pediatric cervical spine

Indexed keywords

ARTICLE; ATLANTOAXIAL DISLOCATION; BONE SCREW; CASE REPORT; CERVICAL SPINE; CHILD; COMPUTER ASSISTED TOMOGRAPHY; DISEASE COURSE; HUMAN; IMAGE RECONSTRUCTION; MALE; PRIORITY JOURNAL; SPINE INSTABILITY; SPINE STABILIZATION; SURGICAL TECHNIQUE; THREE DIMENSIONAL IMAGING; TREATMENT OUTCOME;

EID: 33747093350     PISSN: 10162291     EISSN: None     Source Type: Journal    
DOI: 10.1159/000094073     Document Type: Article
Times cited : (22)

References (26)
  • 1
    • 0024413551 scopus 로고
    • Pathomechanism of atlanto-axial rotatory fixation in children
    • Kawabe N, Hirotani H, Tanaka O: Pathomechanism of atlanto-axial rotatory fixation in children. J Pediatr Orthop 1989;9:569-574.
    • (1989) J Pediatr Orthop , vol.9 , pp. 569-574
    • Kawabe, N.1    Hirotani, H.2    Tanaka, O.3
  • 3
    • 0032532137 scopus 로고    scopus 로고
    • Current management of paediatric atlanto-axial rotatory subluxation
    • Subach BR, McLaughlin MR, Albright AL, et al: Current management of paediatric atlanto-axial rotatory subluxation. Spine 1998;23:2174-2179.
    • (1998) Spine , vol.23 , pp. 2174-2179
    • Subach, B.R.1    McLaughlin, M.R.2    Albright, A.L.3
  • 5
    • 0002454389 scopus 로고
    • Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws
    • The Cervical Spine Research Society (ed): Philadelphia, Lippincott
    • Roy-Camille R, Salient G, Mazel C: Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws; in The Cervical Spine Research Society (ed): The Cervical Spine, ed 2. Philadelphia, Lippincott, 1989, pp 390-403.
    • (1989) The Cervical Spine, Ed 2 , pp. 390-403
    • Roy-Camille, R.1    Salient, G.2    Mazel, C.3
  • 7
    • 0035890208 scopus 로고    scopus 로고
    • 2 fusion with polyaxial screw and rod fixation
    • 2 fusion with polyaxial screw and rod fixation. Spine 2001;26:2467-2471.
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 8
    • 0017367826 scopus 로고
    • Atlanto-axial rotatory fixation (fixed rotatory subluxation of the atlantoaxial joint)
    • Fielding JW, Hawkins RJ: Atlanto-axial rotatory fixation (fixed rotatory subluxation of the atlantoaxial joint). J Bone Joint Surg (Am) 1977;39-A:37-44.
    • (1977) J Bone Joint Surg (Am) , vol.39 A , pp. 37-44
    • Fielding, J.W.1    Hawkins, R.J.2
  • 9
    • 0037115161 scopus 로고    scopus 로고
    • Atlanto-axial rotatory fixation-subluxation revisited
    • Hicazi A, Acaroglu E, Alanay A, et al: Atlanto-axial rotatory fixation-subluxation revisited. Spine 2003;27:2771-2775.
    • (2003) Spine , vol.27 , pp. 2771-2775
    • Hicazi, A.1    Acaroglu, E.2    Alanay, A.3
  • 10
    • 0035659650 scopus 로고    scopus 로고
    • Atlanto-axial rotatory subluxation in children: Early management
    • Martinez-Lage JF, Perez MM, Carnejo VF, et al: Atlanto-axial rotatory subluxation in children: early management. Acta Neurochir 2001;143:1223-1228.
    • (2001) Acta Neurochir , vol.143 , pp. 1223-1228
    • Martinez-Lage, J.F.1    Perez, M.M.2    Carnejo, V.F.3
  • 11
    • 0025139111 scopus 로고
    • Atlanto-axial rotatory fixation and fracture of the clavicle
    • Goddard NJ, Stabler J, Albert JS: Atlanto-axial rotatory fixation and fracture of the clavicle. J Bone Joint Surg (Br) 1990;72:72-75.
    • (1990) J Bone Joint Surg (Br) , vol.72 , pp. 72-75
    • Goddard, N.J.1    Stabler, J.2    Albert, J.S.3
  • 12
    • 0032902986 scopus 로고    scopus 로고
    • A biomechanical evaluation of occipitocervical instrumentation: Screw compared with wire fixation
    • Hurlbert RJ, Crawford NR, Choi WG, Dickman CA: A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation. J Neurosurg (Spine 1) 1999;90:84-90.
    • (1999) J Neurosurg (Spine 1) , vol.90 , pp. 84-90
    • Hurlbert, R.J.1    Crawford, N.R.2    Choi, W.G.3    Dickman, C.A.4
  • 14
    • 0002257576 scopus 로고
    • Stable posterior fusion of the atlas and axis by transarticular screw fixation
    • Kehr P, Weidner A (eds): Wien, Springer
    • Magerl F, Seemann P: Stable posterior fusion of the atlas and axis by transarticular screw fixation; in Kehr P, Weidner A (eds): Cervical Spine. Wien, Springer, 1985, vol 1, pp 322-327.
    • (1985) Cervical Spine , vol.1 , pp. 322-327
    • Magerl, F.1    Seemann, P.2
  • 15
    • 0032143648 scopus 로고    scopus 로고
    • 2 transarticular screw fixation
    • 2 transarticular screw fixation. Spine 1998;23:1703-1707.
    • (1998) Spine , vol.23 , pp. 1703-1707
    • Jun, B.Y.1
  • 17
    • 0027174272 scopus 로고
    • Atlanto-axial stabilization with posterior transarticular screw fixation: Technical description and report of 22 cases
    • Stillerman CB, Wilson JA: Atlanto-axial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases. Neurosurgery 1993;32:948-955.
    • (1993) Neurosurgery , vol.32 , pp. 948-955
    • Stillerman, C.B.1    Wilson, J.A.2
  • 18
    • 0031927701 scopus 로고    scopus 로고
    • 2 transarticular screw fixation for atlantoaxial arthrodesis: Technique application
    • 2 transarticular screw fixation for atlantoaxial arthrodesis: technique application. Neurosurgery 1998;43:275-281.
    • (1998) Neurosurgery , vol.43 , pp. 275-281
    • Dickman, C.A.1    Sonntag, V.K.H.2
  • 19
    • 0032750036 scopus 로고    scopus 로고
    • Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques
    • Oda I, Abumi K, Sell LC, Haggerty CJ, Cunningham BW, McAfee PC: Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques. Spine 1999;24:2377-2382.
    • (1999) Spine , vol.24 , pp. 2377-2382
    • Oda, I.1    Abumi, K.2    Sell, L.C.3    Haggerty, C.J.4    Cunningham, B.W.5    McAfee, P.C.6
  • 20
    • 0032123050 scopus 로고    scopus 로고
    • Transoral joint release of the dislocated atlantoaxial joints combined with posterior reduction and fusion for a late infantile atlantoaxial rotatory fixation: A case report
    • Sumio G, Mochizuki M, Tsuneji K, et al: Transoral joint release of the dislocated atlantoaxial joints combined with posterior reduction and fusion for a late infantile atlantoaxial rotatory fixation: a case report. Spine 1998;23:1485-1489.
    • (1998) Spine , vol.23 , pp. 1485-1489
    • Sumio, G.1    Mochizuki, M.2    Tsuneji, K.3
  • 21
    • 0036330501 scopus 로고    scopus 로고
    • Staged reduction and stabilization in chronic atlantoaxial rotatory fixation
    • Govender S, Kumar KPS: Staged reduction and stabilization in chronic atlantoaxial rotatory fixation. J Bone Joint Surg (Br) 2002;84-B:727-731.
    • (2002) J Bone Joint Surg (Br) , vol.84 B , pp. 727-731
    • Govender, S.1    Kumar, K.P.S.2
  • 22
    • 1542378023 scopus 로고    scopus 로고
    • Open reduction of pediatric atlantoaxial rotatory fixation: Long term outcome study with functional measurements
    • Crossman JE, David K, Hayward R, et al: Open reduction of pediatric atlantoaxial rotatory fixation: long term outcome study with functional measurements. J Neurosurg (Spine 3) 2004;100:235-240.
    • (2004) J Neurosurg (Spine 3) , vol.100 , pp. 235-240
    • Crossman, J.E.1    David, K.2    Hayward, R.3
  • 23
    • 0028012268 scopus 로고
    • Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: Description of the techniques and preliminary report
    • Abumi K, Itoh H, Taneichi H, et al: Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 1994;7:19-28.
    • (1994) J Spinal Disord , vol.7 , pp. 19-28
    • Abumi, K.1    Itoh, H.2    Taneichi, H.3
  • 24
    • 0028284239 scopus 로고
    • Plate and screw fixation for atlanto-axial subluxation
    • Goel A, Laheri V: Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir 1994;129:47-53.
    • (1994) Acta Neurochir , vol.129 , pp. 47-53
    • Goel, A.1    Laheri, V.2
  • 25
    • 0033565624 scopus 로고    scopus 로고
    • Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems
    • Abumi K, Takada T, Shono Y: Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine 1999;24:1425-1434.
    • (1999) Spine , vol.24 , pp. 1425-1434
    • Abumi, K.1    Takada, T.2    Shono, Y.3
  • 26
    • 0028355091 scopus 로고
    • Three-dimensional computed tomography in infantile atlantoaxial rotatory fixation
    • Scapinelli R: Three-dimensional computed tomography in infantile atlantoaxial rotatory fixation. J Bone Joint Surg (Br) 1994;76-B:367-370.
    • (1994) J Bone Joint Surg (Br) , vol.76 B , pp. 367-370
    • Scapinelli, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.