메뉴 건너뛰기




Volumn 31, Issue 3, 2006, Pages 184-189

Optimum parameters of TLD100 powder used for radiotherapy beams calibration check

Author keywords

Beam calibration; Li 100; Reader parameters; TLD100

Indexed keywords

LITHIUM FLUORIDE; NITROGEN;

EID: 33747045551     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.meddos.2006.02.001     Document Type: Article
Times cited : (6)

References (12)
  • 1
    • 0023202277 scopus 로고
    • What degree of accuracy is required and can be achieved in photon and neutron therapy
    • Mijnheer B.J., Battermann J.J., and Wambersie A. What degree of accuracy is required and can be achieved in photon and neutron therapy. Radiother. Oncol. 8 (1987) 237-252
    • (1987) Radiother. Oncol. , vol.8 , pp. 237-252
    • Mijnheer, B.J.1    Battermann, J.J.2    Wambersie, A.3
  • 2
    • 0001944192 scopus 로고
    • Accuracy requirements and quality assurance of external beam therapy with photons and electrons
    • Brahme A., Chavaudra J., Landberg T., et al. Accuracy requirements and quality assurance of external beam therapy with photons and electrons. Acta Oncol. 27 Suppl 1 (1988) 1-76
    • (1988) Acta Oncol. , vol.27 , Issue.SUPPL. 1 , pp. 1-76
    • Brahme, A.1    Chavaudra, J.2    Landberg, T.3
  • 6
    • 0026016296 scopus 로고
    • Quality audit of radiotherapy with EORTC mailed in water TL-dosimetry
    • Hansson U., and Johansson K.-A. Quality audit of radiotherapy with EORTC mailed in water TL-dosimetry. Radiother. Oncol. 20 (1991) 191-196
    • (1991) Radiother. Oncol. , vol.20 , pp. 191-196
    • Hansson, U.1    Johansson, K.-A.2
  • 7
    • 0029011227 scopus 로고
    • A European quality assurance network for radiotherapy. Dose measurement procedure
    • Derreumaux S., Chavaudra J., Bridier A., et al. A European quality assurance network for radiotherapy. Dose measurement procedure. Phys. Med. Biol. 40 (1995) 1191-1208
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1191-1208
    • Derreumaux, S.1    Chavaudra, J.2    Bridier, A.3
  • 10
    • 0026498079 scopus 로고
    • Uncertainty analysis of absorbed dose calculations from thermoluminescent dosimeters
    • Kirby T.H., Hanson W.F., and Johnston D.A. Uncertainty analysis of absorbed dose calculations from thermoluminescent dosimeters. Med. Phys. 19 (1992) 1427-1433
    • (1992) Med. Phys. , vol.19 , pp. 1427-1433
    • Kirby, T.H.1    Hanson, W.F.2    Johnston, D.A.3
  • 11
    • 0015846138 scopus 로고
    • Effects of annealing and cooling processes on thermoluminescence of LiF (TLD100)
    • Dhar A., DeWerd L.A., and Stoebe L.A. Effects of annealing and cooling processes on thermoluminescence of LiF (TLD100). Health Phys. 25 (1973) 427-433
    • (1973) Health Phys. , vol.25 , pp. 427-433
    • Dhar, A.1    DeWerd, L.A.2    Stoebe, L.A.3
  • 12
    • 0036390457 scopus 로고    scopus 로고
    • IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry
    • Izewska J., Bera P., and Vatnitsky S. IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry. Radiat. Protection Dosim. 101 (2002) 387-392
    • (2002) Radiat. Protection Dosim. , vol.101 , pp. 387-392
    • Izewska, J.1    Bera, P.2    Vatnitsky, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.