-
1
-
-
0001944192
-
Accuracy requirements and quality assurance of external beam therapy with photons and electrons
-
Brahme A, Chavaudra J, Landberg T et al: Accuracy requirements and quality assurance of external beam therapy with photons and electrons. Acta Oncol, 1988; 27(Suppl.1): 1-26
-
(1988)
Acta Oncol
, vol.27
, Issue.SUPPL. 1
, pp. 1-26
-
-
Brahme, A.1
Chavaudra, J.2
Landberg, T.3
-
2
-
-
0002428920
-
Uncertainties at the end point of the basic dosimetry chain
-
IAEA, Vienna
-
Thwaites DI: Uncertainties at the end point of the basic dosimetry chain. In: measurement assurance in dosimetry, IAEA, Vienna, 1994
-
(1994)
Measurement Assurance in Dosimetry
-
-
Thwaites, D.I.1
-
3
-
-
0002730551
-
Lung correction in cobalt-60 beam therapy
-
Batho HF: Lung correction in cobalt-60 beam therapy. J Can Assoc Radiol, 1964; Xv: 79-83
-
(1964)
J Can Assoc Radiol
, vol.15
, pp. 79-83
-
-
Batho, H.F.1
-
4
-
-
0014788080
-
Experimental tests of corrections for tissue inhomogenities in radiotherapy
-
Young ME, Gaylord JD: Experimental tests of corrections for tissue inhomogenities in radiotherapy. BJR, 1970; 43: 349-55
-
(1970)
BJR
, vol.43
, pp. 349-355
-
-
Young, M.E.1
Gaylord, J.D.2
-
5
-
-
12944255792
-
Experimental evaluation of ALFARD treatment planning system for 6MV photon irradiation: A lung case study
-
Mesbahi A, Allahverdi M, Gheraati H, Mohammadi E: Experimental evaluation of ALFARD treatment planning system for 6MV photon irradiation: A lung case study. Rep Pract Oncol Radiother, 2004; 9(6): 217-21
-
(2004)
Rep Pract Oncol Radiother
, vol.9
, Issue.6
, pp. 217-221
-
-
Mesbahi, A.1
Allahverdi, M.2
Gheraati, H.3
Mohammadi, E.4
-
6
-
-
0022638891
-
Accuracy of lung dose calculations for large fields irradiation with 6MV X-rays
-
El-Khatib E, Battista [J: Accuracy of lung dose calculations for large fields irradiation with 6MV X-rays. Med Phys, 1986; 13(1): 111-5
-
(1986)
Med Phys
, vol.13
, Issue.1
, pp. 111-115
-
-
El-Khatib, E.1
Battista, J.2
-
7
-
-
0020038518
-
Changes in the dose-profile of a 10MV X-ray beam within and beyond low density material
-
Kornelson RD, Young ME: Changes in the dose-profile of a 10MV X-ray beam within and beyond low density material. Med Phys, 1982; 9: 114-6
-
(1982)
Med Phys
, vol.9
, pp. 114-116
-
-
Kornelson, R.D.1
Young, M.E.2
-
8
-
-
0018885977
-
Half-body radiotherapy: The use of computed tomography to determine the dose to the lung
-
Van Dyk J, Battista JJ, Rider WD: Half-body radiotherapy: the use of computed tomography to determine the dose to the lung. Int J Rad Oncol Biol Phys, 1980; 6: 436-70
-
(1980)
Int J Rad Oncol Biol Phys
, vol.6
, pp. 436-470
-
-
Van Dyk, J.1
Battista, J.J.2
Rider, W.D.3
-
9
-
-
0019978345
-
Batho correction factor with scatter summation
-
Lulu BA, Bjarngard BE: Batho correction factor with scatter summation. Med Phys, 1982; 9(3): 372-7
-
(1982)
Med Phys
, vol.9
, Issue.3
, pp. 372-377
-
-
Lulu, B.A.1
Bjarngard, B.E.2
-
10
-
-
0020607389
-
Dose corrections follow density tissue inhomogenities and air channels for 10MV X-rays
-
Young ME, Kornelson RO: Dose corrections follow density tissue inhomogenities and air channels for 10MV X-rays. Med Phys, 1983; 10: 450-5
-
(1983)
Med Phys
, vol.10
, pp. 450-455
-
-
Young, M.E.1
Kornelson, R.O.2
-
12
-
-
0021876532
-
Lung dose corrections for 6 and 15M X-rays
-
Mackie TR, El-Khatib E, Battista JJ et al: Lung dose corrections for 6 and 15M X-rays. Med Phys, 1985; 12(3): 327-32
-
(1985)
Med Phys
, vol.12
, Issue.3
, pp. 327-332
-
-
Mackie, T.R.1
El-Khatib, E.2
Battista, J.J.3
-
13
-
-
0024430392
-
Evaluation of lung dose correction methods for photon irradiations of thorax phantoms
-
El-Khatib E, Evans M, Pla M, Cunningham JR: Evaluation of lung dose correction methods for photon irradiations of thorax phantoms. Int J Radiat Oncol Biol Phy, 1989; 17: 871-8
-
(1989)
Int J Radiat Oncol Biol Phy
, vol.17
, pp. 871-878
-
-
El-Khatib, E.1
Evans, M.2
Pla, M.3
Cunningham, J.R.4
-
14
-
-
0031950887
-
A CT-based Monte Carlo tool for dosimetry planning and analysis
-
Demarco JJ, Solberg TD: A CT-based Monte Carlo tool for dosimetry planning and analysis. Med Phys, 1998; 25(1): 1-11
-
(1998)
Med Phys
, vol.25
, Issue.1
, pp. 1-11
-
-
Demarco, J.J.1
Solberg, T.D.2
-
15
-
-
0034967139
-
A review of radiation dosimetry application using the MCNP Monte Carlo code
-
Solberg TD, DeMarco JJ, Chetty IJ et al: A review of radiation dosimetry application using the MCNP Monte Carlo code. Radiochim Acta, 2001; 89: 337-55
-
(2001)
Radiochim Acta
, vol.89
, pp. 337-355
-
-
Solberg, T.D.1
DeMarco, J.J.2
Chetty, I.J.3
-
16
-
-
0035996450
-
Undedosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: A comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations
-
Martens C, Reynaert N, De Wagter C et al: Undedosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: A comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations. Med Phys, 2002; 29(7): 1528-35
-
(2002)
Med Phys
, vol.29
, Issue.7
, pp. 1528-1535
-
-
Martens, C.1
Reynaert, N.2
De Wagter, C.3
-
17
-
-
0033795024
-
Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system
-
Ma CM, Pawlicki T, Jiang SB et al: Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system. Phys Med Biol, 2000; 45: 2483-95
-
(2000)
Phys Med Biol
, vol.45
, pp. 2483-2495
-
-
Ma, C.M.1
Pawlicki, T.2
Jiang, S.B.3
-
18
-
-
0035049385
-
Comparison of the Batho, ETAR and Monte Carlo dose calculation methods in CT based patient models
-
Plessis FCP, Willemse CA, Lotter MG: Comparison of the Batho, ETAR and Monte Carlo dose calculation methods in CT based patient models. Med Phys, 2001; 28(4): 582-9
-
(2001)
Med Phys
, vol.28
, Issue.4
, pp. 582-589
-
-
Plessis, F.C.P.1
Willemse, C.A.2
Lotter, M.G.3
-
19
-
-
0343602910
-
The impact of electron transport on the accuracy of computed dose
-
Arnifield MR, Siantar CH, Cox L, Mohan R: The impact of electron transport on the accuracy of computed dose. Med Phys, 2000; 27(6): 1266-74
-
(2000)
Med Phys
, vol.27
, Issue.6
, pp. 1266-1274
-
-
Arnifield, M.R.1
Siantar, C.H.2
Cox, L.3
Mohan, R.4
-
20
-
-
0036680150
-
Dose distribution of narrow beam irradiation for small lung tumor
-
Saitoh H, Fujisaki T, Sakai R, Kunieda E: Dose distribution of narrow beam irradiation for small lung tumor. Int J Radiat Oncol Biol Phys, 2002; 53(5): 1380-7
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.53
, Issue.5
, pp. 1380-1387
-
-
Saitoh, H.1
Fujisaki, T.2
Sakai, R.3
Kunieda, E.4
-
21
-
-
0037394689
-
Photon beam relative dose validation of DPM Monte Carlo code in lung-equivalent media
-
Chetty IJ, Charland PM, Tyagi N, Mc Shan D: Photon beam relative dose validation of DPM Monte Carlo code in lung-equivalent media. Med Phys, 2003; 30(4): 563-73
-
(2003)
Med Phys
, vol.30
, Issue.4
, pp. 563-573
-
-
Chetty, I.J.1
Charland, P.M.2
Tyagi, N.3
Mc Shan, D.4
-
22
-
-
0034986809
-
Intensity modulated irradiation of a thorax phantom: Comparisons between measurements, Monte Carlo calculations and pencil beam calculations
-
Laub WU, Bakai A, Nüsslin F: Intensity modulated irradiation of a thorax phantom: comparisons between measurements, Monte Carlo calculations and pencil beam calculations. Phys Med Biol, 2001; 46(6) 1695-706
-
(2001)
Phys Med Biol
, vol.46
, Issue.6
, pp. 1695-1706
-
-
Laub, W.U.1
Bakai, A.2
Nüsslin, F.3
-
23
-
-
0036130664
-
Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters
-
Sheikh-Bagheri D, Rogers DWO: Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters. Med Phys, 2002; 29(3): 379-90
-
(2002)
Med Phys
, vol.29
, Issue.3
, pp. 379-390
-
-
Sheikh-Bagheri, D.1
Rogers, D.W.O.2
-
24
-
-
1942420368
-
Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
-
Tzedakis A, Damilakis JE, Mazonakis M et al: Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams. Med Phys, 2004; 31(4): 907-13
-
(2004)
Med Phys
, vol.31
, Issue.4
, pp. 907-913
-
-
Tzedakis, A.1
Damilakis, J.E.2
Mazonakis, M.3
-
25
-
-
10644259725
-
Monte Carlo calculation of Varian 2300C/D Linac photon beam characteristics: A comparison between MCNP4C, GEANT3 and measurements
-
Mesbahi, A, Fix M, Allahverdi M et al: Monte Carlo calculation of Varian 2300C/D Linac photon beam characteristics: a comparison between MCNP4C, GEANT3 and measurements. Appl Radiat Isotop, 2005; 62: 469-77
-
(2005)
Appl Radiat Isotop
, vol.62
, pp. 469-477
-
-
Mesbahi, A.1
Fix, M.2
Allahverdi, M.3
-
26
-
-
0034959129
-
Tolerances for the accuracy of photon beam dose calculations of treatment planning systems
-
Venselaar J, Welleweerd H, Mijnheer B: Tolerances for the accuracy of photon beam dose calculations of treatment planning systems. Radiother Oncol, 2001; 60: 191-201
-
(2001)
Radiother Oncol
, vol.60
, pp. 191-201
-
-
Venselaar, J.1
Welleweerd, H.2
Mijnheer, B.3
-
27
-
-
0029939206
-
Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6MV and 15MV photons
-
White PJ, Zwicker RD, Huang DT: Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6MV and 15MV photons. Int J Radiat Oncol Biol Phys, 1996; 34: 1141-6
-
(1996)
Int J Radiat Oncol Biol Phys
, vol.34
, pp. 1141-1146
-
-
White, P.J.1
Zwicker, R.D.2
Huang, D.T.3
-
28
-
-
0030070120
-
Dosimetric considerations in radiation therapy of coin lesions of the lung
-
Yorke E, Harisiadis L, Wessels B et al: Dosimetric considerations in radiation therapy of coin lesions of the lung. Int Rad Oncol Biol Phys, 1996; 34: 481-7
-
(1996)
Int Rad Oncol Biol Phys
, vol.34
, pp. 481-487
-
-
Yorke, E.1
Harisiadis, L.2
Wessels, B.3
-
29
-
-
2342576217
-
Modelling an extreme water-lung interface using a single pencil beam algorithm and Monte Carlo method
-
Cranmer-Sargison G, Beckham WA, Popescu IA. Modelling an extreme water-lung interface using a single pencil beam algorithm and Monte Carlo method. Phys Med Biol, 2004; 49: 1557-67
-
(2004)
Phys Med Biol
, vol.49
, pp. 1557-1567
-
-
Cranmer-Sargison, G.1
Beckham, W.A.2
Popescu, I.A.3
-
30
-
-
7244223251
-
Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium
-
Carrasco P, Jornet N, Dutch MA et al: Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium. Med Phys, 2004; 31(10): 2899-911
-
(2004)
Med Phys
, vol.31
, Issue.10
, pp. 2899-2911
-
-
Carrasco, P.1
Jornet, N.2
Dutch, M.A.3
|