메뉴 건너뛰기




Volumn 80, Issue 1, 2006, Pages 43-50

Assessment of 18F PET signals for automatic target volume definition in radiotherapy treatment planning

Author keywords

Automatic 3D delineation of PET images; FDG PET; Functional imaging based radiotherapy planning; PET CT derived target volume definition; Segmentation of PET signals; Threshold definition

Indexed keywords

FLUORINE 18; FLUORODEOXYGLUCOSE F 18; RADIOPHARMACEUTICAL AGENT;

EID: 33746991225     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2006.07.006     Document Type: Article
Times cited : (71)

References (39)
  • 1
    • 0942289879 scopus 로고    scopus 로고
    • High-tech in radiation oncology: should there be a ceiling?
    • Bentzen S.M. High-tech in radiation oncology: should there be a ceiling?. Int J Radiat Oncol Biol Phys 58 (2004) 320-330
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 320-330
    • Bentzen, S.M.1
  • 2
    • 7444232598 scopus 로고    scopus 로고
    • Defining a radiotherapy target with positron emission tomography
    • Black Q.C., Grills I.S., Kestin L.L., et al. Defining a radiotherapy target with positron emission tomography. Int J Radiat Oncol Biol Phys 60 (2004) 1272-1282
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 1272-1282
    • Black, Q.C.1    Grills, I.S.2    Kestin, L.L.3
  • 3
    • 4444289151 scopus 로고    scopus 로고
    • Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer
    • Bradley J., Thorstad W.L., Mutic S., et al. Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 59 (2004) 78-86
    • (2004) Int J Radiat Oncol Biol Phys , vol.59 , pp. 78-86
    • Bradley, J.1    Thorstad, W.L.2    Mutic, S.3
  • 5
    • 0942278938 scopus 로고    scopus 로고
    • 18F-FDG positron emission tomography staging and restaging in rectal cancer treated with preoperative chemoradiation
    • 18F-FDG positron emission tomography staging and restaging in rectal cancer treated with preoperative chemoradiation. Int J Radiat Oncol Biol Phys 58 (2004) 528-535
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 528-535
    • Calvo, F.A.1    Domper, M.2    Matute, R.3
  • 6
    • 0141615676 scopus 로고    scopus 로고
    • Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT): a feasibility study
    • Ciernik I.F., Dizendorf E., Baumert B.G., et al. Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT): a feasibility study. Int J Radiat Oncol Biol Phys 57 (2003) 853-863
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 853-863
    • Ciernik, I.F.1    Dizendorf, E.2    Baumert, B.G.3
  • 8
    • 0642284535 scopus 로고    scopus 로고
    • 18F-FDG PET and PET/CT in patients with colorectal carcinoma
    • 18F-FDG PET and PET/CT in patients with colorectal carcinoma. J Nucl Med 44 (2003) 1797-1803
    • (2003) J Nucl Med , vol.44 , pp. 1797-1803
    • Cohade, C.1    Osman, M.2    Leal, J.3    Wahl, R.L.4
  • 9
    • 0036176751 scopus 로고    scopus 로고
    • Positron emission tomography scanning: current and future applications
    • Czernin J., and Phelps M.E. Positron emission tomography scanning: current and future applications. Annu Rev Med 53 (2002) 89-112
    • (2002) Annu Rev Med , vol.53 , pp. 89-112
    • Czernin, J.1    Phelps, M.E.2
  • 10
    • 0344440831 scopus 로고    scopus 로고
    • Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients: accuracy, reproducibility and consistency
    • Daisne J.-F., Sibomana M., Bol A., Cosnard G., Lonneux M., and Gregoire V. Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients: accuracy, reproducibility and consistency. Radiother Oncol 69 (2003) 237-245
    • (2003) Radiother Oncol , vol.69 , pp. 237-245
    • Daisne, J.-F.1    Sibomana, M.2    Bol, A.3    Cosnard, G.4    Lonneux, M.5    Gregoire, V.6
  • 11
    • 0345303828 scopus 로고    scopus 로고
    • Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: influence of reconstruction algorithms
    • Daisne J.-F., Sibomana M., Bol A., Doumont T., Lonneux M., and Gregoire V. Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios: influence of reconstruction algorithms. Radiother Oncol 69 (2003) 247-250
    • (2003) Radiother Oncol , vol.69 , pp. 247-250
    • Daisne, J.-F.1    Sibomana, M.2    Bol, A.3    Doumont, T.4    Lonneux, M.5    Gregoire, V.6
  • 12
    • 0036661306 scopus 로고    scopus 로고
    • Quality assurance of the EORTC Trial 22911. A phase III study of post-operative external radiotherapy in pathological stage T3N0 prostatic carcinoma: The dummy run
    • Davis J.B., Reiner B., Dusserre A., Giraud J.-Y., and Bolla M. Quality assurance of the EORTC Trial 22911. A phase III study of post-operative external radiotherapy in pathological stage T3N0 prostatic carcinoma: The dummy run. Radiother Oncol 64 (2002) 65-73
    • (2002) Radiother Oncol , vol.64 , pp. 65-73
    • Davis, J.B.1    Reiner, B.2    Dusserre, A.3    Giraud, J.-Y.4    Bolla, M.5
  • 13
    • 27144513765 scopus 로고    scopus 로고
    • Effects of radiotherapy planning with a dedicated combined PET-CT-simulator of patients with non-small cell lung cancer on dose limiting normal tissues and radiation dose-escalation: a planning study
    • De Ruysscher D., Wanders S., Minken A., et al. Effects of radiotherapy planning with a dedicated combined PET-CT-simulator of patients with non-small cell lung cancer on dose limiting normal tissues and radiation dose-escalation: a planning study. Radiother Oncol 77 (2005) 5-10
    • (2005) Radiother Oncol , vol.77 , pp. 5-10
    • De Ruysscher, D.1    Wanders, S.2    Minken, A.3
  • 15
    • 0028826667 scopus 로고
    • Threshold estimation in single photon emission computed tomography and planar imaging for clinical radio-immunotherapy
    • Erdi Y., Wessels B., Loew M., and Erdi A. Threshold estimation in single photon emission computed tomography and planar imaging for clinical radio-immunotherapy. Cancer Res 55 (1995) 5823s-5826s
    • (1995) Cancer Res , vol.55
    • Erdi, Y.1    Wessels, B.2    Loew, M.3    Erdi, A.4
  • 16
    • 0031457987 scopus 로고    scopus 로고
    • Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding
    • Erdi Y.E., Mawlawi O., Larson S.M., et al. Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding. Cancer 80 (1997) 2505-2509
    • (1997) Cancer , vol.80 , pp. 2505-2509
    • Erdi, Y.E.1    Mawlawi, O.2    Larson, S.M.3
  • 17
    • 0036161956 scopus 로고    scopus 로고
    • Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET)
    • Erdi Y.E., Rosenzweig K., Erdi A.K., et al. Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET). Radiother Oncol 62 (2002) 51-60
    • (2002) Radiother Oncol , vol.62 , pp. 51-60
    • Erdi, Y.E.1    Rosenzweig, K.2    Erdi, A.K.3
  • 18
    • 2542431960 scopus 로고    scopus 로고
    • Role of 11-C-methionine positron emission tomography for the delineation of the tumor volume in pharyngolaryngeal squamous cell carcinoma: comparison with FDG-PET and CT
    • Geets X., Daisne J.-F., Gregoire V., Hamoir M., and Lonneux M. Role of 11-C-methionine positron emission tomography for the delineation of the tumor volume in pharyngolaryngeal squamous cell carcinoma: comparison with FDG-PET and CT. Radiother Oncol 71 (2004) 267-273
    • (2004) Radiother Oncol , vol.71 , pp. 267-273
    • Geets, X.1    Daisne, J.-F.2    Gregoire, V.3    Hamoir, M.4    Lonneux, M.5
  • 19
    • 33746997625 scopus 로고    scopus 로고
    • Results of the dummy-run of EORTC trial no.22961: a phase III study of long term hormonal treatment on locally advanced protatic carcinoma treated by radiation therapy and a 6 months CAB
    • Giraud J.Y., Dusserre A., Conil M., Davis J.B., and Bolla M. Results of the dummy-run of EORTC trial no.22961: a phase III study of long term hormonal treatment on locally advanced protatic carcinoma treated by radiation therapy and a 6 months CAB. Int J Radiat Oncol Biol Phys 51 (2001) 378
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 378
    • Giraud, J.Y.1    Dusserre, A.2    Conil, M.3    Davis, J.B.4    Bolla, M.5
  • 20
    • 0036162284 scopus 로고    scopus 로고
    • Conformal radiotherapy for lung cancer: different delineation of the gross tumor volume (GTV) by radiologists and radiation oncologists
    • Giraud P., Elles S., Helfre S., et al. Conformal radiotherapy for lung cancer: different delineation of the gross tumor volume (GTV) by radiologists and radiation oncologists. Radiother Oncol 62 (2002) 27-36
    • (2002) Radiother Oncol , vol.62 , pp. 27-36
    • Giraud, P.1    Elles, S.2    Helfre, S.3
  • 21
    • 1642535536 scopus 로고    scopus 로고
    • Test performance of positron emission tomography and computed tomography for mediastinal staging in patients with non-small-cell lung cancer: a meta-analysis
    • Gould M.K., Kuschner W.G., Rydzak C.E., et al. Test performance of positron emission tomography and computed tomography for mediastinal staging in patients with non-small-cell lung cancer: a meta-analysis. Ann Intern Med 139 (2003) 879-892
    • (2003) Ann Intern Med , vol.139 , pp. 879-892
    • Gould, M.K.1    Kuschner, W.G.2    Rydzak, C.E.3
  • 22
    • 10044273157 scopus 로고    scopus 로고
    • Is there any future in radiotherapy planning without the use of PET: unravelling the myth
    • Gregoire V. Is there any future in radiotherapy planning without the use of PET: unravelling the myth. Radiother Oncol 73 (2004) 261-263
    • (2004) Radiother Oncol , vol.73 , pp. 261-263
    • Gregoire, V.1
  • 23
    • 10044254554 scopus 로고    scopus 로고
    • Results of a phase I study to dose escalate using intensity modulated radiotherapy guided by combined PET/CT imaging with induction chemotherapy for patients with non-small cell lung cancer
    • Holloway C.L., Robinson D., Murray B., et al. Results of a phase I study to dose escalate using intensity modulated radiotherapy guided by combined PET/CT imaging with induction chemotherapy for patients with non-small cell lung cancer. Radiother Oncol 73 (2004) 285-287
    • (2004) Radiother Oncol , vol.73 , pp. 285-287
    • Holloway, C.L.1    Robinson, D.2    Murray, B.3
  • 24
    • 0033702918 scopus 로고    scopus 로고
    • Kenneth E, Hoff I, Culver T, Keyser J, Lin M, Manocha D. Fast computation of generalized Voronoi diagrams using graphics hardware. In: Proceedings of the sixteenth annual symposium on computational geometry; 2000. p. 375-6.
  • 25
    • 0025885790 scopus 로고
    • Integration of multimodality imaging data for radiotherapy treatment planning
    • Kessler M.L., Pitluck S., Petti P., and Castro J.R. Integration of multimodality imaging data for radiotherapy treatment planning. Int J Radiat Oncol Biol Phys 21 (1991) 1653-1667
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 1653-1667
    • Kessler, M.L.1    Pitluck, S.2    Petti, P.3    Castro, J.R.4
  • 26
    • 4644269135 scopus 로고    scopus 로고
    • Quality assurance of the 22961 EORTC trial. A phase III study of the optimal combination of hormonal adjuvant treatment by LHRH analogue and radiation therapy for the management of locally advanced prostate cancer: the dummy run
    • Kouloulias V.E., Giraud J.-Y., Davis B.J., Dusserre A., Zurlo A., and Bolla M. Quality assurance of the 22961 EORTC trial. A phase III study of the optimal combination of hormonal adjuvant treatment by LHRH analogue and radiation therapy for the management of locally advanced prostate cancer: the dummy run. Radiother Oncol 73 (2004) 11-20
    • (2004) Radiother Oncol , vol.73 , pp. 11-20
    • Kouloulias, V.E.1    Giraud, J.-Y.2    Davis, B.J.3    Dusserre, A.4    Zurlo, A.5    Bolla, M.6
  • 27
    • 0037792992 scopus 로고    scopus 로고
    • Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography
    • Lardinois D., Weder W., Hany T.F., et al. Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 348 (2003) 2500-2507
    • (2003) N Engl J Med , vol.348 , pp. 2500-2507
    • Lardinois, D.1    Weder, W.2    Hany, T.F.3
  • 28
    • 27144488327 scopus 로고    scopus 로고
    • Positron emission tomography for target volume definition in the treatment of non-small cell lung cancer
    • Lavrenkov K., Partridge M., Cook G., and Brada M. Positron emission tomography for target volume definition in the treatment of non-small cell lung cancer. Radiother Oncol 77 (2005) 1-4
    • (2005) Radiother Oncol , vol.77 , pp. 1-4
    • Lavrenkov, K.1    Partridge, M.2    Cook, G.3    Brada, M.4
  • 29
    • 10044246142 scopus 로고    scopus 로고
    • 18F-FDG-PET scans to radiotherapy planning of thoracic lymphoma
    • 18F-FDG-PET scans to radiotherapy planning of thoracic lymphoma. Radiother Oncol 73 (2004) 277-283
    • (2004) Radiother Oncol , vol.73 , pp. 277-283
    • Lee, Y.K.1    Cook, G.2    Flower, M.A.3
  • 30
    • 25444452894 scopus 로고    scopus 로고
    • 18F-FDG PET-positive tissue for target volume definition in radiotherapy of patients with non-small cell lung cancer
    • 18F-FDG PET-positive tissue for target volume definition in radiotherapy of patients with non-small cell lung cancer. J Nucl Med 46 (2005) 1342-1348
    • (2005) J Nucl Med , vol.46 , pp. 1342-1348
    • Nestle, U.1    Kremp, S.2    Schaefer-Schuler, A.3
  • 31
    • 33746957569 scopus 로고    scopus 로고
    • Prescribing, recording and reporting photon beam therapy, ICRU Report, 50. Bethesda, MD: The International Commission on Radiation Units And Measurements; 1993.
  • 32
    • 33746969569 scopus 로고    scopus 로고
    • Prescribing, recording and reporting photon beam therapy, ICRU Report, 62. Bethesda, MD: The International Commission on Radiation Units And Measurements; 1999.
  • 34
    • 0031960822 scopus 로고    scopus 로고
    • Quality assurance of the EORTC radiotherapy trial 22931 for head and neck carcinomas: the dummy run
    • Valley J.-F., Bernier J., Tercier P.-A., et al. Quality assurance of the EORTC radiotherapy trial 22931 for head and neck carcinomas: the dummy run. Radiother Oncol 47 (1998) 37-44
    • (1998) Radiother Oncol , vol.47 , pp. 37-44
    • Valley, J.-F.1    Bernier, J.2    Tercier, P.-A.3
  • 35
    • 0027441847 scopus 로고
    • Comparison of treatment techniques for lung cancer
    • Valley J.F., and RO M. Comparison of treatment techniques for lung cancer. Radiother Oncol 28 (1993) 168-173
    • (1993) Radiother Oncol , vol.28 , pp. 168-173
    • Valley, J.F.1    RO, M.2
  • 36
    • 0034195192 scopus 로고    scopus 로고
    • 18F-fluoro-2-deoxy- glucose positron emission tomography (FDG-PET) lymph node staging on the radiation treatment volumes in patients with non-small cell lung cancer
    • 18F-fluoro-2-deoxy- glucose positron emission tomography (FDG-PET) lymph node staging on the radiation treatment volumes in patients with non-small cell lung cancer. Radiother Oncol 55 (2000) 317-324
    • (2000) Radiother Oncol , vol.55 , pp. 317-324
    • Vanuytsel, L.J.1    Vansteenkiste, J.F.2    Stroobants, S.G.3
  • 37
    • 84927514013 scopus 로고
    • Nouvelles Applications des paramètres continus à la théorie des formes quadratiques. Deuxième Mémoire: Recherches sur les paralléloèdres primitifs
    • Voronoi G.M. Nouvelles Applications des paramètres continus à la théorie des formes quadratiques. Deuxième Mémoire: Recherches sur les paralléloèdres primitifs. J Reine Angew Math 134 (1908) 198-287
    • (1908) J Reine Angew Math , vol.134 , pp. 198-287
    • Voronoi, G.M.1
  • 38
    • 10044264504 scopus 로고    scopus 로고
    • Is there a role for FGD-PET in radiotherapy planning in esophageal carcinoma?
    • Vrieze O., Haustermans K., Wever W.D., et al. Is there a role for FGD-PET in radiotherapy planning in esophageal carcinoma?. Radiother Oncol 73 (2004) 269-275
    • (2004) Radiother Oncol , vol.73 , pp. 269-275
    • Vrieze, O.1    Haustermans, K.2    Wever, W.D.3
  • 39
    • 18144366233 scopus 로고    scopus 로고
    • Threshold modification for tumour imaging in non-small-cell lung cancer using positron emission tomography
    • Yaremko B., Riauka T., Robinson D., Murray B., McEwan A., and Roa W. Threshold modification for tumour imaging in non-small-cell lung cancer using positron emission tomography. Nucl Med Commun 26 (2005) 433-440
    • (2005) Nucl Med Commun , vol.26 , pp. 433-440
    • Yaremko, B.1    Riauka, T.2    Robinson, D.3    Murray, B.4    McEwan, A.5    Roa, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.