메뉴 건너뛰기




Volumn 27, Issue 4, 2006, Pages 321-332

Evaluation of left ventricular ejection fraction by the quantitative algorithms qgs, ectb, lmc and lvgtf using gated myocardial perfusion spect: investigation of relative accuracy

Author keywords

Gated Myocardial SPECT; Left ventricular EF; Quantitative methods; Relative accuracy

Indexed keywords

ALGORITHM; ARTICLE; ARTIFICIAL INTELLIGENCE; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER PROGRAM; EVALUATION; FEMALE; GATED IMAGING; HEART LEFT VENTRICLE FUNCTION; HEART STROKE VOLUME; HUMAN; MALE; METHODOLOGY; RETROSPECTIVE STUDY; SCINTISCANNING; SENSITIVITY AND SPECIFICITY; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; VALIDATION STUDY; ADULT; AGED; ANALYSIS OF VARIANCE; ANGINA PECTORIS; ASTHMA; CALCULATION; CORONARY ARTERY BYPASS GRAFT; CORRELATION COEFFICIENT; DIABETES MELLITUS; DIAGNOSTIC ACCURACY; HEART EJECTION FRACTION; HEART INFARCTION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART MUSCLE PERFUSION; HEART SIZE; HEART VENTRICLE CONTRACTION; HEART VENTRICLE ENDDIASTOLIC PRESSURE; HYPERTENSION; MAJOR CLINICAL STUDY; REGRESSION ANALYSIS; SAMPLE SIZE; SEX RATIO; SMOKING; STUDENT T TEST; TRANSLUMINAL CORONARY ANGIOPLASTY;

EID: 33746884324     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/01.mnm.0000202861.67293.95     Document Type: Article
Times cited : (16)

References (33)
  • 1
    • 0034966235 scopus 로고    scopus 로고
    • Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction
    • Sharir T, Germano G, Kang X, Lewin HC, Miranda R, Cohen I, et al. Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction. J Nucl Med 2001; 42:831-837.
    • (2001) J Nucl Med , vol.42 , pp. 831-837
    • Sharir, T.1    Germano, G.2    Kang, X.3    Lewin, H.C.4    Miranda, R.5    Cohen, I.6
  • 2
    • 0028807605 scopus 로고
    • Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
    • Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138-2147.
    • (1995) J Nucl Med , vol.36 , pp. 2138-2147
    • Germano, G.1    Kiat, H.2    Kavanagh, P.B.3    Moriel, M.4    Mazzanti, M.5    Su, H.T.6
  • 3
    • 0032908274 scopus 로고    scopus 로고
    • Left ventricular function and perfusion from gated perfusion images: an integrated method
    • Faber TL, Cooke CD, Folks RD, Vansant JP, Nichols KJ, DePuey EG, et al. Left ventricular function and perfusion from gated perfusion images: an integrated method. J Nucl Med 1999; 40:650-659.
    • (1999) J Nucl Med , vol.40 , pp. 650-659
    • Faber, T.L.1    Cooke, C.D.2    Folks, R.D.3    Vansant, J.P.4    Nichols, K.J.5    DePuey, E.G.6
  • 4
    • 18044368618 scopus 로고    scopus 로고
    • Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods
    • Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G, et al. Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. J Nucl Cardiol 2001; 8:645-651.
    • (2001) J Nucl Cardiol , vol.8 , pp. 645-651
    • Faber, T.L.1    Vansant, J.P.2    Pettigrew, R.I.3    Galt, J.R.4    Blais, M.5    Chatzimavroudis, G.6
  • 5
    • 0035354932 scopus 로고    scopus 로고
    • The prolate spheroidal transform for gated SPECT
    • Feng B, Sitek A, Gulberg GT. The prolate spheroidal transform for gated SPECT. IEEE Trans Nucl Sci 2001; 48:872-875.
    • (2001) IEEE Trans Nucl Sci , vol.48 , pp. 872-875
    • Feng, B.1    Sitek, A.2    Gulberg, G.T.3
  • 6
    • 0036084251 scopus 로고    scopus 로고
    • Calculation of the left ventricular ejection fraction without edge detection: application to small hearts
    • Feng B, Sitek A, Gullberg GT. Calculation of the left ventricular ejection fraction without edge detection: application to small hearts. J Nucl Med 2002; 43:786-794.
    • (2002) J Nucl Med , vol.43 , pp. 786-794
    • Feng, B.1    Sitek, A.2    Gullberg, G.T.3
  • 7
    • 0031453815 scopus 로고    scopus 로고
    • Quantitative gated SPECT imaging: a counts-based method for display and measurement of regional and global ventricular systolic function
    • Smith WH, Kastner RJ, Calnon DA, Segalla D, Beller GA, Watson DD. Quantitative gated SPECT imaging: a counts-based method for display and measurement of regional and global ventricular systolic function. J Nucl Cardiol 1997; 5:451-463.
    • (1997) J Nucl Cardiol , vol.5 , pp. 451-463
    • Smith, W.H.1    Kastner, R.J.2    Calnon, D.A.3    Segalla, D.4    Beller, G.A.5    Watson, D.D.6
  • 8
    • 0031464780 scopus 로고    scopus 로고
    • Validation of a new counts-based gated single photon emission computed tomography method for quantifying left ventricular systolic function: comparison with equilibrium radionuclide angiography
    • Calnon DA, Kastner RJ, Smith WH, Segalla D, Beller GA, Watson DD. Validation of a new counts-based gated single photon emission computed tomography method for quantifying left ventricular systolic function: comparison with equilibrium radionuclide angiography. J Nucl Cardiol 1997; 4:464-471.
    • (1997) J Nucl Cardiol , vol.4 , pp. 464-471
    • Calnon, D.A.1    Kastner, R.J.2    Smith, W.H.3    Segalla, D.4    Beller, G.A.5    Watson, D.D.6
  • 9
    • 0034796989 scopus 로고    scopus 로고
    • Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs
    • Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med 2001; 42:1571-1578.
    • (2001) J Nucl Med , vol.42 , pp. 1571-1578
    • Nakajima, K.1    Higuchi, T.2    Taki, J.3    Kawano, M.4    Tonami, N.5
  • 10
    • 0033766532 scopus 로고    scopus 로고
    • Assessment of left ventricular ejection fraction with quantitative gated SPECT: accuracy and correlation with first-pass radionuclide angiography
    • Vallejo E, Dione DP, Sinusas AJ, Wackers FJ. Assessment of left ventricular ejection fraction with quantitative gated SPECT: accuracy and correlation with first-pass radionuclide angiography. J Nucl Cardiol 2000; 7:461-470.
    • (2000) J Nucl Cardiol , vol.7 , pp. 461-470
    • Vallejo, E.1    Dione, D.P.2    Sinusas, A.J.3    Wackers, F.J.4
  • 11
    • 0034101963 scopus 로고    scopus 로고
    • Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI
    • Vallejo E, Dione DP, Bruni WL, Constable RT, Borek PP, Soares JP, et al. Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI. J Nucl Med 2000; 41:874-882.
    • (2000) J Nucl Med , vol.41 , pp. 874-882
    • Vallejo, E.1    Dione, D.P.2    Bruni, W.L.3    Constable, R.T.4    Borek, P.P.5    Soares, J.P.6
  • 12
    • 0030810148 scopus 로고    scopus 로고
    • Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography
    • Germano G, Erel J, Lewin H, Kavanagh PB, Berman DS. Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1997; 30:1360-1367.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1360-1367
    • Germano, G.1    Erel, J.2    Lewin, H.3    Kavanagh, P.B.4    Berman, D.S.5
  • 13
    • 0028337464 scopus 로고
    • Determining the accuracy of calculating systolic wall thickening using a Fast Fourier Transform Approximation: A simulation study based on canine and patient data
    • Cooke CD, Garcia EV, Cullom SJ, Faber TL, Pettigrew RI. Determining the accuracy of calculating systolic wall thickening using a Fast Fourier Transform Approximation: A simulation study based on canine and patient data. J Nucl Med 1994; 35:1185-1192.
    • (1994) J Nucl Med , vol.35 , pp. 1185-1192
    • Cooke, C.D.1    Garcia, E.V.2    Cullom, S.J.3    Faber, T.L.4    Pettigrew, R.I.5
  • 14
    • 0033895267 scopus 로고    scopus 로고
    • Echocardiographic validation of Gated SPECT ventricular function measurements
    • Nichols K, Lefkowitz D, Faber T, Folks R, Cooke D, Garcia EV, et al. Echocardiographic validation of Gated SPECT ventricular function measurements. J Nucl Med 2000; 41:1308-1314.
    • (2000) J Nucl Med , vol.41 , pp. 1308-1314
    • Nichols, K.1    Lefkowitz, D.2    Faber, T.3    Folks, R.4    Cooke, D.5    Garcia, E.V.6
  • 15
    • 0141430927 scopus 로고    scopus 로고
    • Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT
    • Lum DP, Coel MN. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT. Nucl Med Commun 2003; 24:259-266.
    • (2003) Nucl Med Commun , vol.24 , pp. 259-266
    • Lum, D.P.1    Coel, M.N.2
  • 16
    • 0036587018 scopus 로고    scopus 로고
    • Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT
    • Nichols K, Santana CA, Folks R, Krawczynska E, Cooke CD, Faber TL, et al. Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT. J Nucl Cardiol 2002; 9:285-293.
    • (2002) J Nucl Cardiol , vol.9 , pp. 285-293
    • Nichols, K.1    Santana, C.A.2    Folks, R.3    Krawczynska, E.4    Cooke, C.D.5    Faber, T.L.6
  • 19
    • 26444521659 scopus 로고    scopus 로고
    • 99mTc-tetrofosmin gated SPECT in patients with small hearts: correlation with gated blood pool
    • 99mTc-tetrofosmin gated SPECT in patients with small hearts: correlation with gated blood pool. Nucl Med Commun 2005; 26:885-893.
    • (2005) Nucl Med Commun , vol.26 , pp. 885-893
    • Khalil, M.M.1    Elgazzar, A.2    Khalil, W.3    Omar, A.4    Ziada, G.5
  • 20
    • 0027504581 scopus 로고
    • Separate acquisition rest thallium-201/stress, technetium-99m sestamibi dual isotope myocardial perfusion SPECT: a clinical validation study
    • Berman DS, Kiat H, Wang FP, van Train K, Matzer L, et al. Separate acquisition rest thallium-201/stress, technetium-99m sestamibi dual isotope myocardial perfusion SPECT: a clinical validation study. J Am Coll Cardiol 1993; 22:1455-1464.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1455-1464
    • Berman, D.S.1    Kiat, H.2    Wang, F.P.3    van Train, K.4    Matzer, L.5
  • 21
    • 0027234155 scopus 로고
    • Quantitative same-day rest stress technetium-99m-Sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality
    • Van Train K, Areeda J, Garcia EV, Cooke CD, Maddahi J, Kiat H, et al. Quantitative same-day rest stress technetium-99m-Sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality. J Nucl Med 1993; 34:1494-1502.
    • (1993) J Nucl Med , vol.34 , pp. 1494-1502
    • Van Train, K.1    Areeda, J.2    Garcia, E.V.3    Cooke, C.D.4    Maddahi, J.5    Kiat, H.6
  • 22
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 23
    • 1842641454 scopus 로고    scopus 로고
    • 99mTc tetrofosmin gated SPECT measurements of left ventricular volumes and ejection fraction with MRI over a wide range of values
    • 99mTc tetrofosmin gated SPECT measurements of left ventricular volumes and ejection fraction with MRI over a wide range of values. Nucl Med Commun 2003; 24:763-769.
    • (2003) Nucl Med Commun , vol.24 , pp. 763-769
    • Thorley, P.J.1    Plein, S.2    Bloomer, T.N.3    Ridgway, J.P.4    Sivananthan, U.M.5
  • 25
    • 0038376150 scopus 로고    scopus 로고
    • Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis
    • Kondo C, Fukushima K, Kusakabe K. Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis. Eur J Nucl Med Mol Imaging 2003; 30:851-858.
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 851-858
    • Kondo, C.1    Fukushima, K.2    Kusakabe, K.3
  • 26
    • 0033837575 scopus 로고    scopus 로고
    • Comparison of two three-dimensional gated SPECT methods with thallium in patients with large myocardial infarction
    • Vera P, Koning R, Cribier A, Manrique A. Comparison of two three-dimensional gated SPECT methods with thallium in patients with large myocardial infarction. J Nucl Cardiol 2000; 7:312-319.
    • (2000) J Nucl Cardiol , vol.7 , pp. 312-319
    • Vera, P.1    Koning, R.2    Cribier, A.3    Manrique, A.4
  • 27
    • 0032587875 scopus 로고    scopus 로고
    • 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography
    • 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med 1999; 40:805-809.
    • (1999) J Nucl Med , vol.40 , pp. 805-809
    • Manrique, A.1    Faraggi, M.2    Vera, P.3    Vilain, D.4    Lebtahi, R.5    Cribier, A.6    Guludec, D.7
  • 28
    • 0031039039 scopus 로고    scopus 로고
    • A hybrid method for measuring myocardial wall thickening from gated PET/SPECT images
    • Buvat I, Bartlett ML, Kitsiou AN, Dilsizian V, Bacharach SL. A hybrid method for measuring myocardial wall thickening from gated PET/SPECT images. J Nucl Med 1997; 38:324-329.
    • (1997) J Nucl Med , vol.38 , pp. 324-329
    • Buvat, I.1    Bartlett, M.L.2    Kitsiou, A.N.3    Dilsizian, V.4    Bacharach, S.L.5
  • 29
    • 0030835689 scopus 로고    scopus 로고
    • Quantification of systolic count increase in technetium-99m-MIBI gated myocardial SPECT
    • Fukuchi K, Uehara T, Morozumi T, Tsujimura E, Hasegawa S, Yutani, et al. Quantification of systolic count increase in technetium-99m-MIBI gated myocardial SPECT. J Nucl Med 1997; 38:1067-1073.
    • (1997) J Nucl Med , vol.38 , pp. 1067-1073
    • Fukuchi, K.1    Uehara, T.2    Morozumi, T.3    Tsujimura, E.4    Hasegawa, S.5    Yutani6
  • 30
    • 0031542447 scopus 로고    scopus 로고
    • Postischemic stunning can affect left ventricular ejection fraction and regional wall motion on post-stress gated sestamibi tomograms
    • Johnson LL, Verdesca SA, Aude WY, Xavier RC, Nott LT, Campanella MW, Germano G. Postischemic stunning can affect left ventricular ejection fraction and regional wall motion on post-stress gated sestamibi tomograms. J Am Coll Cardiol 1997; 30:1641-1648.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1641-1648
    • Johnson, L.L.1    Verdesca, S.A.2    Aude, W.Y.3    Xavier, R.C.4    Nott, L.T.5    Campanella, M.W.6    Germano, G.7
  • 31
    • 0033405335 scopus 로고    scopus 로고
    • Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise
    • Hashimoto J, Kubo A, Iwasaki R, Iwanaga S, Mitamura H, Ogawa S, Kosuda S. Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise. Eur J Nucl Med 1999; 26:1541-1546.
    • (1999) Eur J Nucl Med , vol.26 , pp. 1541-1546
    • Hashimoto, J.1    Kubo, A.2    Iwasaki, R.3    Iwanaga, S.4    Mitamura, H.5    Ogawa, S.6    Kosuda, S.7
  • 32
    • 15844415677 scopus 로고    scopus 로고
    • 99mTc-sestamibi
    • 99mTc-sestamibi. Chest 2005; 127:778-786.
    • (2005) Chest , vol.127 , pp. 778-786
    • Lapeyre, A.C.1
  • 33
    • 20744453356 scopus 로고    scopus 로고
    • Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging
    • Papavassiliu T, Kuhl HP, Schroder M, Suselbeck T, Bondarenko O, Bohm CK. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology 2005; 236:57-64.
    • (2005) Radiology , vol.236 , pp. 57-64
    • Papavassiliu, T.1    Kuhl, H.P.2    Schroder, M.3    Suselbeck, T.4    Bondarenko, O.5    Bohm, C.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.