메뉴 건너뛰기




Volumn 2, Issue 2, 2006, Pages 67-72

Changes in cerebral oximetry during peritoneal insufflation for laparoscopic procedures

Author keywords

Cerebral oxygenation; Laparoscopy; Near infrared spectroscopy

Indexed keywords


EID: 33746862230     PISSN: 09729941     EISSN: None     Source Type: Journal    
DOI: 10.4103/0972-9941.26651     Document Type: Article
Times cited : (24)

References (24)
  • 1
    • 0014822524 scopus 로고
    • Some effects of the peritoneal insufflation of carbon dioxide at laparoscopy
    • Hodgson C, McClelland R, Newton J. Some effects of the peritoneal insufflation of carbon dioxide at laparoscopy. Anaesthesia 1970;25:382-90.
    • (1970) Anaesthesia , vol.25 , pp. 382-390
    • Hodgson, C.1    McClelland, R.2    Newton, J.3
  • 3
    • 12744253452 scopus 로고    scopus 로고
    • The physiologic effects of pneumoperitoneum in the morbidly obese
    • Nguyen NT, Wolfe BM. The physiologic effects of pneumoperitoneum in the morbidly obese. Ann Surg 2005;241:219-26.
    • (2005) Ann Surg , vol.241 , pp. 219-226
    • Nguyen, N.T.1    Wolfe, B.M.2
  • 4
    • 0026031228 scopus 로고
    • Complications of laparoscopic cholecystectomy
    • Ponsky JL. Complications of laparoscopic cholecystectomy. Am J Surg 1991;161:393-5.
    • (1991) Am J Surg , vol.161 , pp. 393-395
    • Ponsky, J.L.1
  • 7
    • 0017571334 scopus 로고
    • Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • Jobsis FF. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 1977;198:1264-7.
    • (1977) Science , vol.198 , pp. 1264-1267
    • Jobsis, F.F.1
  • 9
    • 0036183566 scopus 로고    scopus 로고
    • A comparison of the INVOS 4100 and the NIRO 300 near-infrared spectrophotometers
    • Yoshitani K, Kawaguchi M, Tatsumi K, Kitaguchi K, Furuya H. A comparison of the INVOS 4100 and the NIRO 300 near-infrared spectrophotometers. Anesth Analg 2002;94:586-90.
    • (2002) Anesth Analg , vol.94 , pp. 586-590
    • Yoshitani, K.1    Kawaguchi, M.2    Tatsumi, K.3    Kitaguchi, K.4    Furuya, H.5
  • 12
    • 0033015038 scopus 로고    scopus 로고
    • Continuous measurement of cerebral oxygenation by near infrared spectroscopy during induction of anesthesia
    • Lovell AT, Owen-Reece H, Elwell CE. Continuous measurement of cerebral oxygenation by near infrared spectroscopy during induction of anesthesia. Anesth Analg 1999;88:554-8.
    • (1999) Anesth Analg , vol.88 , pp. 554-558
    • Lovell, A.T.1    Owen-Reece, H.2    Elwell, C.E.3
  • 13
    • 0036301739 scopus 로고    scopus 로고
    • Cerebral oxygen saturation assessed by near-infrared spectroscopy during coronary artery bypass grafting and early postoperative cognitive function
    • Reents W, Muellges W, Franke D, Babin-Ebell J, Elert O. Cerebral oxygen saturation assessed by near-infrared spectroscopy during coronary artery bypass grafting and early postoperative cognitive function. Ann Thorac Surg 2002;74:109-14.
    • (2002) Ann Thorac Surg , vol.74 , pp. 109-114
    • Reents, W.1    Muellges, W.2    Franke, D.3    Babin-Ebell, J.4    Elert, O.5
  • 14
    • 0033779446 scopus 로고    scopus 로고
    • Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy
    • Samra SK, Dy EA, Welch K, Dorje P, Zelenock GB, Stanley JC. Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy. Anestheiology 2000;93:964-70.
    • (2000) Anestheiology , vol.93 , pp. 964-970
    • Samra, S.K.1    Dy, E.A.2    Welch, K.3    Dorje, P.4    Zelenock, G.B.5    Stanley, J.C.6
  • 15
    • 0029144311 scopus 로고
    • Near-infrared measurement of cerebral oxygenation
    • Levy WJ, Levin S, Chance B. Near-infrared measurement of cerebral oxygenation. Anesthesiology 1995;83:738-46.
    • (1995) Anesthesiology , vol.83 , pp. 738-746
    • Levy, W.J.1    Levin, S.2    Chance, B.3
  • 17
    • 0031973127 scopus 로고    scopus 로고
    • Accuracy of a cerebral oximeter in healthy volunteers under conditions of isocapnic hypoxia
    • Henson LC, Calalang C, Temp JA, Ward DS. Accuracy of a cerebral oximeter in healthy volunteers under conditions of isocapnic hypoxia. Anesthesiology 1998;88:58-65.
    • (1998) Anesthesiology , vol.88 , pp. 58-65
    • Henson, L.C.1    Calalang, C.2    Temp, J.A.3    Ward, D.S.4
  • 18
    • 0030059050 scopus 로고    scopus 로고
    • Validation in volunteers of a near-infrared spectroscope for monitoring brain oxygenation in vivo
    • Pollard V, Prough DS, DeMelo AE, Deyo DJ, Uchida T, Stoddart HF. Validation in volunteers of a near-infrared spectroscope for monitoring brain oxygenation in vivo. Anesth Analg 1996;82:269-77.
    • (1996) Anesth Analg , vol.82 , pp. 269-277
    • Pollard, V.1    Prough, D.S.2    Demelo, A.E.3    Deyo, D.J.4    Uchida, T.5    Stoddart, H.F.6
  • 19
    • 3242784750 scopus 로고    scopus 로고
    • Regional cerebral oxygen saturation is a sensitive marker of cerebral hypoperfusion during orthotopic liver transplantation
    • Plachky J, Hofer S, Volkmann M, Martin E, Bardenheuer HJ, Weigand MA. Regional cerebral oxygen saturation is a sensitive marker of cerebral hypoperfusion during orthotopic liver transplantation. Anesth Analg 2004;99:344-9.
    • (2004) Anesth Analg , vol.99 , pp. 344-349
    • Plachky, J.1    Hofer, S.2    Volkmann, M.3    Martin, E.4    Bardenheuer, H.J.5    Weigand, M.A.6
  • 20
    • 23944521347 scopus 로고    scopus 로고
    • Continuous monitoring of cerebral oxygen saturation in elderly patients undergoing major abdominal surgery minimizes brain exposure to potential hypoxia
    • Casati A, Fanelli G, Pietropaoli P, Proietti R, Tufano R, Danelli G, et al. Continuous monitoring of cerebral oxygen saturation in elderly patients undergoing major abdominal surgery minimizes brain exposure to potential hypoxia. Anesth Analg 2005;101:740-7.
    • (2005) Anesth Analg , vol.101 , pp. 740-747
    • Casati, A.1    Fanelli, G.2    Pietropaoli, P.3    Proietti, R.4    Tufano, R.5    Danelli, G.6
  • 22
    • 0032415906 scopus 로고    scopus 로고
    • Response of cerebral oxygen metabolism in the head-up position during laparoscopic cholecystectomy
    • Kitajima T, Okuda Y, Yamaguchi S, Takanishi T, Kumagai M, Ido K. Response of cerebral oxygen metabolism in the head-up position during laparoscopic cholecystectomy. Surg Lap Endo 1998;8:449-52.
    • (1998) Surg Lap Endo , vol.8 , pp. 449-452
    • Kitajima, T.1    Okuda, Y.2    Yamaguchi, S.3    Takanishi, T.4    Kumagai, M.5    Ido, K.6
  • 23
    • 0036181141 scopus 로고    scopus 로고
    • The effects of low-pressure carbon dioxide pneumoperitoneum on cerebral oxygenation and cerebral blood volume in children
    • de Waal EC, Vries JW, Kruitwagen CL, Kalkman CJ. The effects of low-pressure carbon dioxide pneumoperitoneum on cerebral oxygenation and cerebral blood volume in children. Anesth Analg 2002;94:500-5.
    • (2002) Anesth Analg , vol.94 , pp. 500-505
    • De Waal, E.C.1    Vries, J.W.2    Kruitwagen, C.L.3    Kalkman, C.J.4
  • 24
    • 0033047260 scopus 로고    scopus 로고
    • Hemodynamic consequence of high and low pressure capnoperitoneum during laparoscopic cholecystectomy
    • Dexter SP, Vucevic M, Gibson J, McMahon MJ. Hemodynamic consequence of high and low pressure capnoperitoneum during laparoscopic cholecystectomy. Surg Endosc 1999;13:376-81.
    • (1999) Surg Endosc , vol.13 , pp. 376-381
    • Dexter, S.P.1    Vucevic, M.2    Gibson, J.3    McMahon, M.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.