메뉴 건너뛰기




Volumn 3, Issue 7, 2006, Pages

Slip velocity direction impacts wear in total knee arthroplasty

Author keywords

Cross shear motion; Slip velocity; Total knee arthroplasty; UHMWPE; Wear

Indexed keywords

COMPUTER SIMULATION; ORTHOPEDICS; PATIENT TREATMENT; POLYETHYLENES; SURGERY; VECTORS; VELOCITY;

EID: 33746862203     PISSN: None     EISSN: 1546962X     Source Type: Journal    
DOI: 10.1520/stp40882s     Document Type: Article
Times cited : (2)

References (15)
  • 1
    • 0343074071 scopus 로고
    • The knee
    • Church Livingstone, London, NY
    • Kapandji, I. A., "The Knee," in: The Physiology of Joints, Church Livingstone, London, NY, 1970, pp. 72-106.
    • (1970) The Physiology of Joints , pp. 72-106
    • Kapandji, I.A.1
  • 4
    • 19944385952 scopus 로고    scopus 로고
    • The influence of slip velocity on wear of total knee arthroplasty
    • Schwenke, T., Borgstede, L. L., Schneider, E., Andriacchi, T. P., and Wimmer, M. A., "The Influence of Slip Velocity on Wear of Total Knee Arthroplasty," Wear, Vol. 259, 2005, pp. 926-932.
    • (2005) Wear , vol.259 , pp. 926-932
    • Schwenke, T.1    Borgstede, L.L.2    Schneider, E.3    Andriacchi, T.P.4    Wimmer, M.A.5
  • 7
    • 0035482037 scopus 로고    scopus 로고
    • The effect of displacement control input parameters on tibiofemoral prosthetic knee wear
    • Johnson, T. S., Laurent, M. P., Yao, J. Q., and Gilbertson, L. N., "The Effect of Displacement Control Input Parameters on Tibiofemoral Prosthetic Knee Wear," Wear, Vol. 250, 2001, pp. 222-226.
    • (2001) Wear , vol.250 , pp. 222-226
    • Johnson, T.S.1    Laurent, M.P.2    Yao, J.Q.3    Gilbertson, L.N.4
  • 9
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
    • Wang, A., Stark, C., and Dumbleton, J. H., "Mechanistic and Morphological Origins of Ultra-High Molecular Weight Polyethylene Wear Debris in Total Joint Replacement Prostheses," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., Vol. 210, No. 3, 1996, pp. 137-140.
    • (1996) Proc. Inst. Mech. Eng., Part H: J. Eng. Med. , vol.210 , Issue.3 , pp. 137-140
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3
  • 10
    • 0034925922 scopus 로고    scopus 로고
    • The effect of molecular orientation and acetylene-enhanced crosslinking on the wear of UHMWPE in total artificial joints
    • Marrs, H., Barton, D. C., Doyle, C., Jones, R. A., Lewis, E. L. V., Ward, I. M., and Fisher, J., "The Effect of Molecular Orientation and Acetylene-Enhanced Crosslinking on the Wear of UHMWPE in total Artificial Joints," J. Mater. Sci.: Mater. Med., Vol. 12, 2001, pp. 621-628.
    • (2001) J. Mater. Sci.: Mater. Med. , vol.12 , pp. 621-628
    • Marrs, H.1    Barton, D.C.2    Doyle, C.3    Jones, R.A.4    Lewis, E.L.V.5    Ward, I.M.6    Fisher, J.7
  • 11
    • 0036205442 scopus 로고    scopus 로고
    • Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators
    • Saikko, V. and Calonius, O., "Slide Track Analysis of the Relative Motion Between Femoral Head and Acetabular Cup in Walking and in Hip Simulators," J. Biomech., Vol. 35, No. 4, 2002, pp. 455-464.
    • (2002) J. Biomech. , vol.35 , Issue.4 , pp. 455-464
    • Saikko, V.1    Calonius, O.2
  • 12
    • 0032411404 scopus 로고    scopus 로고
    • A point cluster method for in vivo motion analysis: Applied to a study of knee kinematics
    • Andriacchi, T. P., Alexander, E. J., Toney, M. K., Dyrby, C., and Sum, J., "A Point Cluster Method for in vivo Motion Analysis: Applied to a Study of Knee Kinematics," J. Biomech. Eng., Vol. 120, No. 6, 1998, pp. 743-749.
    • (1998) J. Biomech. Eng. , vol.120 , Issue.6 , pp. 743-749
    • Andriacchi, T.P.1    Alexander, E.J.2    Toney, M.K.3    Dyrby, C.4    Sum, J.5
  • 14
    • 2442447086 scopus 로고    scopus 로고
    • Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis
    • Saikko, V., Calonius, O., and Keranen, J., "Effect of Slide Track Shape on the Wear of Ultra-high Molecular Weight Polyethylene in a Pin-on-Disk Wear Simulation of Total Hip Prosthesis," J. Biomed. Mater. Res., Vol. 69B, No. 2, 2004, pp. 141-148.
    • (2004) J. Biomed. Mater. Res. , vol.69 B , Issue.2 , pp. 141-148
    • Saikko, V.1    Calonius, O.2    Keranen, J.3
  • 15
    • 0031894928 scopus 로고    scopus 로고
    • A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of miller-galante total knee arthroplasty
    • Wimmer, M. A., Andriacchi, T. P., Natarajan, R. N., Loos, J., Karlhuber, M., Petermann, J., Schneider, E., and Rosenberg, A. G., "A Striated Pattern of Wear in Ultrahigh-Molecular-Weight Polyethylene Components of Miller-Galante Total Knee Arthroplasty," J. Arthroplasty, Vol. 13, No. 1 1998, pp. 8-16.
    • (1998) J. Arthroplasty , vol.13 , Issue.1 , pp. 8-16
    • Wimmer, M.A.1    Andriacchi, T.P.2    Natarajan, R.N.3    Loos, J.4    Karlhuber, M.5    Petermann, J.6    Schneider, E.7    Rosenberg, A.G.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.