메뉴 건너뛰기




Volumn 18, Issue 8, 2006, Pages 359-362

Feasibility of a pressure wire and single arterial puncture for assessing aortic valve area in patients with aortic stenosis

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; AORTA PRESSURE; AORTA STENOSIS; AORTA VALVE; ARTERY PUNCTURE; ARTICLE; ASCENDING AORTA; CALIBRATION; CARDIAC PATIENT; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DOPPLER ECHOCARDIOGRAPHY; FEASIBILITY STUDY; FEMALE; HEART CATHETERIZATION; HEART LEFT VENTRICLE; HEART LEFT VENTRICLE PRESSURE; HEART OUTPUT MEASUREMENT; HEMODYNAMIC MONITORING; HUMAN; INTERMETHOD COMPARISON; INVASIVE PROCEDURE; LOCAL ANESTHESIA; MALE; PATIENT SAFETY; PRESSURE GRADIENT; PRESSURE MEASUREMENT; PULMONARY ARTERY CATHETER; THERMODILUTION;

EID: 33746859736     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (18)

References (11)
  • 1
    • 50449114923 scopus 로고
    • Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I
    • Gorlin R, Gorlin SG. Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. Am Heart J 1951;41:1-29.
    • (1951) Am Heart J , vol.41 , pp. 1-29
    • Gorlin, R.1    Gorlin, S.G.2
  • 2
    • 0024587783 scopus 로고
    • Accurate determination of the transaortic valve gradient using simultaneous left ventricular and femoral artery pressures
    • Krueger SK, Orme EC, King CS, Barry WH. Accurate determination of the transaortic valve gradient using simultaneous left ventricular and femoral artery pressures. Cathet Cardiovasc Diagn 1989;16:202-206.
    • (1989) Cathet Cardiovasc Diagn , vol.16 , pp. 202-206
    • Krueger, S.K.1    Orme, E.C.2    King, C.S.3    Barry, W.H.4
  • 4
    • 0027176226 scopus 로고
    • Double-lumen catheter assessment of aortic stenosis: Comparison with separate catheter technique
    • Jayne JE, Catherwood E, Niles NW, Friedman BJ. Double-lumen catheter assessment of aortic stenosis: Comparison with separate catheter technique. Cathet Cardiovasc Diagn 1993;29:157-160.
    • (1993) Cathet Cardiovasc Diagn , vol.29 , pp. 157-160
    • Jayne, J.E.1    Catherwood, E.2    Niles, N.W.3    Friedman, B.J.4
  • 5
    • 0018677565 scopus 로고
    • Changes in arterial pressure during left heart pullback in patients with aortic stenosis: A sign of severe aortic stenosis
    • Carabello BA, Barry WH, Grossman W. Changes in arterial pressure during left heart pullback in patients with aortic stenosis: A sign of severe aortic stenosis. Am J Cardiol 1979;44:424-427.
    • (1979) Am J Cardiol , vol.44 , pp. 424-427
    • Carabello, B.A.1    Barry, W.H.2    Grossman, W.3
  • 6
    • 0034904946 scopus 로고    scopus 로고
    • Hemodynamic rounds: Transvalvular pressure gradient measurement
    • Fusman B, Faxon D, Feldman T. Hemodynamic rounds: Transvalvular pressure gradient measurement. Catheter Cardiovasc Interv 2001;53:553-561.
    • (2001) Catheter Cardiovasc Interv , vol.53 , pp. 553-561
    • Fusman, B.1    Faxon, D.2    Feldman, T.3
  • 7
    • 0022454974 scopus 로고
    • Death due to transprosthetic catheterization of a Bjork-Shiley prosthesis in the aortic position
    • Horstkotte D, Jehle J, Loogen F. Death due to transprosthetic catheterization of a Bjork-Shiley prosthesis in the aortic position. Am J Cardiol 1986;58:566-567.
    • (1986) Am J Cardiol , vol.58 , pp. 566-567
    • Horstkotte, D.1    Jehle, J.2    Loogen, F.3
  • 8
    • 0041664901 scopus 로고    scopus 로고
    • Retrograde left ventricular hemodynamic assessment across bileaflet prosthetic aortic valves: The use of a high-fidelity pressure sensor angioplasty guidewire
    • Parham W, El Shafei A, Rajjoub H, et al. Retrograde left ventricular hemodynamic assessment across bileaflet prosthetic aortic valves: The use of a high-fidelity pressure sensor angioplasty guidewire. Catheter Cardiovasc Interv 2003;59:509-513.
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 509-513
    • Parham, W.1    El Shafei, A.2    Rajjoub, H.3
  • 9
    • 0024366586 scopus 로고
    • Simultaneous left ventricular and ascending aortic pressure measurements via single artery access for assessment of aortic stenosis
    • Nath A, Vetrovec GW, Mukharji J, et al. Simultaneous left ventricular and ascending aortic pressure measurements via single artery access for assessment of aortic stenosis. Cathet Cardiovasc Diagn 1989;17:126-130.
    • (1989) Cathet Cardiovasc Diagn , vol.17 , pp. 126-130
    • Nath, A.1    Vetrovec, G.W.2    Mukharji, J.3
  • 10
    • 0018826031 scopus 로고
    • Aortic input impedance in normal man: Relationship to pressure wave forms
    • Murgo JP, Westerhof N, Giolma JP, Altobelli SA. Aortic input impedance in normal man: Relationship to pressure wave forms. Circulation 1980;62:105-116.
    • (1980) Circulation , vol.62 , pp. 105-116
    • Murgo, J.P.1    Westerhof, N.2    Giolma, J.P.3    Altobelli, S.A.4
  • 11
    • 33646013645 scopus 로고    scopus 로고
    • Feasibility assessment of aortic valve area in patients with aortic stenosis using a pressure wire through a 4 French system and single femoral arterial access
    • Bertog SC, Smith A, Panetta CJ. Feasibility assessment of aortic valve area in patients with aortic stenosis using a pressure wire through a 4 French system and single femoral arterial access. J Invasive Cardiol 2005;17:E24-E26.
    • (2005) J Invasive Cardiol , vol.17
    • Bertog, S.C.1    Smith, A.2    Panetta, C.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.