메뉴 건너뛰기




Volumn 13, Issue 5, 2006, Pages 357-363

Improved efficiency of budesonide nebulization using surface-active agents

Author keywords

Detergent; Ionic Charge; Nebulization; Particle size; Surfactants

Indexed keywords

BUDESONIDE; DETERGENT; SURFACTANT;

EID: 33746811824     PISSN: 10717544     EISSN: 15210464     Source Type: Journal    
DOI: 10.1080/10717540500458862     Document Type: Article
Times cited : (6)

References (27)
  • 1
    • 0033406815 scopus 로고    scopus 로고
    • An in vitro analysis of the output of budesonide from different nebulizers
    • Barry, P. W., and O'Callaghan, C. 1999. An in vitro analysis of the output of budesonide from different nebulizers. J. Allergy Clin. Immunol. 104:1168-1173.
    • (1999) J. Allergy Clin. Immunol. , vol.104 , pp. 1168-1173
    • Barry, P.W.1    O'Callaghan, C.2
  • 3
    • 0008974003 scopus 로고
    • Output and particle size distribution of Pulmicort suspension generated from MAD2 and Pariboy jet nebulizers
    • Berg, E., Backstrom, K., Dhalback, M., and Nerbrink, O. 1988. Output and particle size distribution of Pulmicort suspension generated from MAD2 and Pariboy jet nebulizers. J. Aerosol Sci. 19: 1093-1096.
    • (1988) J. Aerosol Sci. , vol.19 , pp. 1093-1096
    • Berg, E.1    Backstrom, K.2    Dhalback, M.3    Nerbrink, O.4
  • 4
    • 0031436033 scopus 로고    scopus 로고
    • Effect of aerosol delivery system and formulation on nebulized budesonide output
    • Berlinski, A., and Waldrep, J. C. 1997. Effect of aerosol delivery system and formulation on nebulized budesonide output. J. Aerosol Med. 10:307-318.
    • (1997) J. Aerosol Med. , vol.10 , pp. 307-318
    • Berlinski, A.1    Waldrep, J.C.2
  • 5
    • 0031913574 scopus 로고    scopus 로고
    • Comparative study of budesonide as a nebulized suspension versus pressurized metered-dose inhaler in adult asthmatics
    • Bisgaard, H., Nikander, K., and Munch, E. 1998. Comparative study of budesonide as a nebulized suspension versus pressurized metered-dose inhaler in adult asthmatics (abstract). Resp. Med. 92:44-49.
    • (1998) Resp. Med. , vol.92 , pp. 44-49
    • Bisgaard, H.1    Nikander, K.2    Munch, E.3
  • 6
    • 0033990466 scopus 로고    scopus 로고
    • Optical measurement of nebulizer sprays: A quantitative comparison of diffraction, phase doppler interferometry and time of flight techniques
    • Corcoran, T. E. Hitron, R. Humphrey, W., and Chigier, N. 2000. Optical measurement of nebulizer sprays: a quantitative comparison of diffraction, phase doppler interferometry and time of flight techniques. J. Aerosol Sci. 31(1):35-50.
    • (2000) J. Aerosol Sci. , vol.31 , Issue.1 , pp. 35-50
    • Corcoran, T.E.1    Hitron, R.2    Humphrey, W.3    Chigier, N.4
  • 8
    • 85012562184 scopus 로고
    • Physical principles underlying aerosol therapy
    • Dolovich, M. B. 1989. Physical principles underlying aerosol therapy. J. Aerosol Med. 2:171-186.
    • (1989) J. Aerosol Med. , vol.2 , pp. 171-186
    • Dolovich, M.B.1
  • 9
    • 0010289523 scopus 로고    scopus 로고
    • Aerosol therapy and delivery systems
    • ed. Taussig, L. M., and Landau L. I. St. Louis, MO: Mosby
    • Everard, M. L., and LeSouëf, P. N. 1999. Aerosol therapy and delivery systems. In Pediatric Respiratory Medicine, ed. Taussig, L. M., and Landau L. I. St. Louis, MO: Mosby.
    • (1999) Pediatric Respiratory Medicine
    • Everard, M.L.1    LeSouëf, P.N.2
  • 10
    • 0031918170 scopus 로고    scopus 로고
    • Surfactant versus saline as a vehicle for corticosteroid delivery to the lungs of ventilated rabbits
    • Fajardo, C., Levin, D., Garcia, M., et al. 1998. Surfactant versus saline as a vehicle for corticosteroid delivery to the lungs of ventilated rabbits. Pediatr. Res. 43:542-547.
    • (1998) Pediatr. Res. , vol.43 , pp. 542-547
    • Fajardo, C.1    Levin, D.2    Garcia, M.3
  • 11
    • 0022889862 scopus 로고
    • Deposition of particles in the human respiratory tract in the size range 0.005-15 mcm
    • Heyder, J., Gebhart, J., Rudolf, G., et al. 1986. Deposition of particles in the human respiratory tract in the size range 0.005-15 mcm. J. Aerosol Sci. 17:811-825.
    • (1986) J. Aerosol Sci. , vol.17 , pp. 811-825
    • Heyder, J.1    Gebhart, J.2    Rudolf, G.3
  • 12
    • 8244262146 scopus 로고
    • Particle size analysis of nebulised aerosols using Fraunhofer laser diffraction and inertial compaction methods
    • Ho, K. K. L., Kellaway, I. W., and Tredree, R. 1986. Particle size analysis of nebulised aerosols using Fraunhofer laser diffraction and inertial compaction methods. J. Pharm. Pharmacol. 38:26.
    • (1986) J. Pharm. Pharmacol. , vol.38 , pp. 26
    • Ho, K.K.L.1    Kellaway, I.W.2    Tredree, R.3
  • 13
    • 0030660261 scopus 로고    scopus 로고
    • Treatment of asthma in children; revised guidelines by pediatric pneumologists
    • Hoekstra, M. O. 1997. Treatment of asthma in children; revised guidelines by pediatric pneumologists. Ned. Tijdschr. Geneesk 141:2223-2228.
    • (1997) Ned. Tijdschr. Geneesk , vol.141 , pp. 2223-2228
    • Hoekstra, M.O.1
  • 14
    • 0033663263 scopus 로고    scopus 로고
    • Budesonide Inhalation Suspension
    • Hvizdos, K. M., and Jarvis, B. 2000. Budesonide Inhalation Suspension. Drugs 60:1141-1178.
    • (2000) Drugs , vol.60 , pp. 1141-1178
    • Hvizdos, K.M.1    Jarvis, B.2
  • 15
    • 0027511611 scopus 로고
    • Treatment of severe steroid dependent preschool children with nebulised budesonide suspension
    • Ilangovan, P., Pedersen, S., Godfrey, S., et al. 1993. Treatment of severe steroid dependent preschool children with nebulised budesonide suspension. Arch. Dis. Child 68:356-359.
    • (1993) Arch. Dis. Child , vol.68 , pp. 356-359
    • Ilangovan, P.1    Pedersen, S.2    Godfrey, S.3
  • 16
    • 0026591050 scopus 로고    scopus 로고
    • International consensus report on diagnosis and management of asthma, 1992
    • International consensus report on diagnosis and management of asthma, 1992. Eur. Respir. J: 5:601-641.
    • Eur. Respir. J , vol.5 , pp. 601-641
  • 17
    • 0034492461 scopus 로고    scopus 로고
    • Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus Andersen cascade impactor and low-flow Marple personal cascade impactor
    • Kwong, W. T., Ho, S. L., and Coates, A. L. 2000. Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus Andersen cascade impactor and low-flow Marple personal cascade impactor. J. Aerosol Med. 13(4):303-14.
    • (2000) J. Aerosol Med. , vol.13 , Issue.4 , pp. 303-314
    • Kwong, W.T.1    Ho, S.L.2    Coates, A.L.3
  • 18
    • 0026699356 scopus 로고
    • How much nebulised budesonide reaches infants and toddlers?
    • Lødrup Carlsen, K. C., Nikander, K., and Carlsen, K.-H. 1992. How much nebulised budesonide reaches infants and toddlers? Arch. Dis. Child. 67:1077-1079.
    • (1992) Arch. Dis. Child. , vol.67 , pp. 1077-1079
    • Lødrup Carlsen, K.C.1    Nikander, K.2    Carlsen, K.-H.3
  • 19
    • 0033836983 scopus 로고    scopus 로고
    • Comparable efficacy of administration with facemask or mouthpiece of nebulized budesonide inhalation suspension for infants and young children with persistent asthma
    • Mellon, M., Leflein, J., Walton-Bowen, K., et al. 2000. Comparable efficacy of administration with facemask or mouthpiece of nebulized budesonide inhalation suspension for infants and young children with persistent asthma. Am. J. Respir. Crit. Care Med 162:593-598.
    • (2000) Am. J. Respir. Crit. Care Med. , vol.162 , pp. 593-598
    • Mellon, M.1    Leflein, J.2    Walton-Bowen, K.3
  • 20
    • 0032863201 scopus 로고    scopus 로고
    • Impact of constant and breath-synchronized nebulization on inhaled mass of nebulized budesonide in infants and children
    • Nikander, K., and Bisgaard, H. 1999. Impact of constant and breath-synchronized nebulization on inhaled mass of nebulized budesonide in infants and children. Pediatr. Pulmonol. 28:187-193.
    • (1999) Pediatr. Pulmonol. , vol.28 , pp. 187-193
    • Nikander, K.1    Bisgaard, H.2
  • 21
    • 0034491747 scopus 로고    scopus 로고
    • Effect of budesonide and salbutamol on surfactant properties
    • Palmer, D., Schurch, S., and Belik, J. 2000. Effect of budesonide and salbutamol on surfactant properties. J. Appl. Physiol. 89:884-890.
    • (2000) J. Appl. Physiol. , vol.89 , pp. 884-890
    • Palmer, D.1    Schurch, S.2    Belik, J.3
  • 22
    • 0035158173 scopus 로고    scopus 로고
    • Note: Dissolution of aerosol particles of budesonide in Survanta™, a model lung surfactant
    • Pham, S. and Wiedmann, T. S. 2001. Note: dissolution of aerosol particles of budesonide in Survanta™, a model lung surfactant. J. Pharm. Sci. 90:98-103.
    • (2001) J. Pharm. Sci. , vol.90 , pp. 98-103
    • Pham, S.1    Wiedmann, T.S.2
  • 23
    • 0033495184 scopus 로고    scopus 로고
    • Pharmacodynamics and pharmacokinetics of budesonide: A new nebulized corticosteroid
    • Szefler, S. J. 1999. Pharmacodynamics and pharmacokinetics of budesonide: a new nebulized corticosteroid. J. Allergy Clin. Immunol. 104:S175-S183.
    • (1999) J. Allergy Clin. Immunol. , vol.104
    • Szefler, S.J.1
  • 24
    • 0031834167 scopus 로고    scopus 로고
    • In vitro determination of inhaled mass and particle distribution for budesonide nebulizing suspension
    • Smaldone, G. C., et al. 1998. In vitro determination of inhaled mass and particle distribution for budesonide nebulizing suspension. J. Aerosol Med. 11:113-125.
    • (1998) J. Aerosol Med. , vol.11 , pp. 113-125
    • Smaldone, G.C.1
  • 25
    • 0031859941 scopus 로고    scopus 로고
    • Errors in characterizing nebulized particle size distributions with cascade impactors
    • Stapleton, K. W., and Finlay, W. H. 1998. Errors in characterizing nebulized particle size distributions with cascade impactors. J. Aerosol Med. 11:S80-S83.
    • (1998) J. Aerosol Med. , vol.11
    • Stapleton, K.W.1    Finlay, W.H.2
  • 26


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.