메뉴 건너뛰기




Volumn 44, Issue 8, 2006, Pages 1022-1029

Evaluation of the analytical performance of the advanced method for cardiac troponin I for the AxSYM platform: Comparison with the old method and the Access system

Author keywords

Acute coronary syndrome; Acute myocardial infarction; Cardiac troponin I (cTnI); Immunoassay; Method comparison; Troponin assay

Indexed keywords

RHEUMATOID FACTOR; TROPONIN I;

EID: 33746763722     PISSN: 14346621     EISSN: 14346621     Source Type: Journal    
DOI: 10.1515/CCLM.2006.175     Document Type: Article
Times cited : (5)

References (24)
  • 1
    • 0033851515 scopus 로고    scopus 로고
    • Myocardial infarction redefined - A consensus document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction
    • Alpert J, Thygesen K, for the Joint European Society of Cardiology/American College of Cardiology Committee. Myocardial infarction redefined - a consensus document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction. J Am Coll Cardiol 2000;36:959-69.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 959-969
    • Alpert, J.1    Thygesen, K.2
  • 2
    • 0036788546 scopus 로고    scopus 로고
    • American College of Cardiology/ American Heart Association Task Force on practice guidelines (Committee on the Management of Patients with Unstable Angina): ACC/AHA guideline update for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction - 2002: Summary article: A report of the American College of Cardiology
    • American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients With Unstable Angina)
    • Braunwald E, Antman EM, Beasley JW, Califf RM, Cheitlin MD, Hochman JS, et al. American College of Cardiology/ American Heart Association Task Force on practice guidelines (Committee on the Management of Patients With Unstable Angina): ACC/AHA guideline update for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction - 2002: Summary article: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients With Unstable Angina). Circulation 2002;106:1893-2000.
    • (2002) Circulation , vol.106 , pp. 1893-2000
    • Braunwald, E.1    Antman, E.M.2    Beasley, J.W.3    Califf, R.M.4    Cheitlin, M.D.5    Hochman, J.S.6
  • 3
    • 0344444877 scopus 로고    scopus 로고
    • Case definitions for acute coronary heart disease in epidemiology and clinical research studies
    • Luepker RV, Apple FS, Christenson RH, Crow RS, Fortmann SP, Goff D, et al. Case definitions for acute coronary heart disease in epidemiology and clinical research studies. Circulation 2003;108:2543-9.
    • (2003) Circulation , vol.108 , pp. 2543-2549
    • Luepker, R.V.1    Apple, F.S.2    Christenson, R.H.3    Crow, R.S.4    Fortmann, S.P.5    Goff, D.6
  • 4
    • 0035102976 scopus 로고    scopus 로고
    • Standardization of cardiac troponin I assays: Round robin often candidate reference materials
    • Christenson RH, Duh SH, Apple FS, Bodor GS, Bunk DM, Dalluge J, et al. Standardization of cardiac troponin I assays: round robin often candidate reference materials. Clin Chem 2001;47:431-7.
    • (2001) Clin Chem , vol.47 , pp. 431-437
    • Christenson, R.H.1    Duh, S.H.2    Apple, F.S.3    Bodor, G.S.4    Bunk, D.M.5    Dalluge, J.6
  • 5
    • 0742304262 scopus 로고    scopus 로고
    • Evaluation of imprecision for cardiac troponin assays at low-range concentrations
    • Committee on Standardization of Markers of Cardiac Damage of the IFCC
    • Panteghini M, Pagani F, Yeo KT, Apple FS, Christenson RH, Dati F, et al. Committee on Standardization of Markers of Cardiac Damage of the IFCC. Evaluation of imprecision for cardiac troponin assays at low-range concentrations. Clin Chem 2004;50:327-32.
    • (2004) Clin Chem , vol.50 , pp. 327-332
    • Panteghini, M.1    Pagani, F.2    Yeo, K.T.3    Apple, F.S.4    Christenson, R.H.5    Dati, F.6
  • 6
    • 18744396059 scopus 로고    scopus 로고
    • The diagnostic utility of cardiac biomarkers in detecting myocardial infarction
    • Apple FS, Murakami MM. The diagnostic utility of cardiac biomarkers in detecting myocardial infarction. Clin Cornerstone 2005;7(Suppl 1):S25-30.
    • (2005) Clin Cornerstone , vol.7 , Issue.1 SUPPL.
    • Apple, F.S.1    Murakami, M.M.2
  • 7
    • 11144305199 scopus 로고    scopus 로고
    • Analytical issues for cardiac troponin
    • Apple FS. Analytical issues for cardiac troponin. Prog Cardiovasc Dis 2005;47:189-95.
    • (2005) Prog Cardiovasc Dis , vol.47 , pp. 189-195
    • Apple, F.S.1
  • 9
    • 33746711582 scopus 로고    scopus 로고
    • REF 2J44 34-3355/R2. Abbott Park, IL: Abbott Laboratories, Diagnostic Division
    • Abbott Laboratories. AxSYM Troponin-I ADV assay package insert, REF 2J44 34-3355/R2. Abbott Park, IL: Abbott Laboratories, Diagnostic Division, 2004.
    • (2004) AxSYM Troponin-I ADV Assay Package Insert
  • 10
    • 10444242448 scopus 로고    scopus 로고
    • Beckman Access versus the Bayer ACS:180 and the Abbott AxSYM cardiac troponin-I real-time immunoassays: An observational prospective study
    • Baevsky RH, Kapur RK, Smithline HA. Beckman Access versus the Bayer ACS:180 and the Abbott AxSYM cardiac troponin-I real-time immunoassays: an observational prospective study. BMC Emerg Med 2004;4:1-8.
    • (2004) BMC Emerg Med , vol.4 , pp. 1-8
    • Baevsky, R.H.1    Kapur, R.K.2    Smithline, H.A.3
  • 11
    • 0041963115 scopus 로고    scopus 로고
    • Plasma 99th percentile reference limits for cardiac troponin and creatine kinase MB mass for use with European Society of Cardiology/American College of Cardiology consensus recommendations
    • Apple FS, Quist H, Doyle PJ, Otto AP, Murakami MM. Plasma 99th percentile reference limits for cardiac troponin and creatine kinase MB mass for use with European Society of Cardiology/American College of Cardiology consensus recommendations. Clin Chem 2003;49:1331-6.
    • (2003) Clin Chem , vol.49 , pp. 1331-1336
    • Apple, F.S.1    Quist, H.2    Doyle, P.J.3    Otto, A.P.4    Murakami, M.M.5
  • 12
    • 0036910739 scopus 로고    scopus 로고
    • European Society of Cardiology and American College of Cardiology guidelines for redefinition of myocardial infarction: How to use existing assays clinically and for clinical trials
    • Apple FS, Wu AH, Jaffe AS. European Society of Cardiology and American College of Cardiology guidelines for redefinition of myocardial infarction: how to use existing assays clinically and for clinical trials. Am Heart J 2002;144:981-6.
    • (2002) Am Heart J , vol.144 , pp. 981-986
    • Apple, F.S.1    Wu, A.H.2    Jaffe, A.S.3
  • 13
    • 33746780628 scopus 로고    scopus 로고
    • Beckman Coulter, Inc, 4300 Harbor blvd., Fullerton, CA 92835, USA: Beckman Instruments
    • Beckman Instruments. AccuTnI Beckman Access Troponin I assay package insert (bulletin 9761). Beckman Coulter, Inc, 4300 Harbor blvd., Fullerton, CA 92835, USA: Beckman Instruments, 2002.
    • (2002) AccuTnI Beckman Access Troponin I Assay Package Insert (Bulletin 9761)
  • 15
    • 33746755290 scopus 로고    scopus 로고
    • Determination of sensitivity and specificity for the AxSYM troponin-I ADV assay at three clinical reference points
    • Qiu KY, Sokolowski L, Bouma SR, Sumerdon GA, Biegalski TT, Gardiner ME, et al. Determination of sensitivity and specificity for the AxSYM troponin-I ADV assay at three clinical reference points [abstract]. Clin Chem 2005; 51(Suppl 6):A17-8.
    • (2005) Clin Chem , vol.51 , Issue.6 SUPPL.
    • Qiu, K.Y.1    Sokolowski, L.2    Bouma, S.R.3    Sumerdon, G.A.4    Biegalski, T.T.5    Gardiner, M.E.6
  • 17
    • 0032923760 scopus 로고    scopus 로고
    • Clinical and analytical standardization issues confronting cardiac troponin I
    • Apple FS. Clinical and analytical standardization issues confronting cardiac troponin I. Clin Chem 1999;45:18-20.
    • (1999) Clin Chem , vol.45 , pp. 18-20
    • Apple, F.S.1
  • 18
    • 31844437194 scopus 로고    scopus 로고
    • Characterization of a new certified reference material for human cardiac troponin I
    • Bunk DM, Welch MJ. Characterization of a new certified reference material for human cardiac troponin I. Clin Chem 2006;52:212-9.
    • (2006) Clin Chem , vol.52 , pp. 212-219
    • Bunk, D.M.1    Welch, M.J.2
  • 19
    • 0032742968 scopus 로고    scopus 로고
    • High percentage of false positive cardiac troponin I results in patients with rheumatoid factor
    • Krahn J, Parry D, Leroux M, Dalton J. High percentage of false positive cardiac troponin I results in patients with rheumatoid factor. Clin Biochem 1999;32:477-80.
    • (1999) Clin Biochem , vol.32 , pp. 477-480
    • Krahn, J.1    Parry, D.2    Leroux, M.3    Dalton, J.4
  • 20
    • 0033975404 scopus 로고    scopus 로고
    • Effect of rheumatoid factor on cardiac troponin I measurements using two commercial measurement systems
    • Onuska KD, Hill SA. Effect of rheumatoid factor on cardiac troponin I measurements using two commercial measurement systems. Clin Chem 2000;46:307-8.
    • (2000) Clin Chem , vol.46 , pp. 307-308
    • Onuska, K.D.1    Hill, S.A.2
  • 21
    • 0033248168 scopus 로고    scopus 로고
    • False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum
    • Dasgupta A, Banerjee SK, Datta P. False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Am J Clin Pathol 1999;112:753-6.
    • (1999) Am J Clin Pathol , vol.112 , pp. 753-756
    • Dasgupta, A.1    Banerjee, S.K.2    Datta, P.3
  • 22
    • 0035195835 scopus 로고    scopus 로고
    • False positive elevation of cardiac troponin I in seropositive rheumatoid arthritis
    • Katwa G, Komatireddy G, Walker SE. False positive elevation of cardiac troponin I in seropositive rheumatoid arthritis. J Rheumatol 2001;28:2750-1.
    • (2001) J Rheumatol , vol.28 , pp. 2750-2751
    • Katwa, G.1    Komatireddy, G.2    Walker, S.E.3
  • 23
    • 22244486943 scopus 로고    scopus 로고
    • Falsely elevated cardiac troponin-I in patients with seropositive rheumatoid arthritis
    • Kenny PR, Finger DR. Falsely elevated cardiac troponin-I in patients with seropositive rheumatoid arthritis. J Rheumatol 2005;32:1258-60.
    • (2005) J Rheumatol , vol.32 , pp. 1258-1260
    • Kenny, P.R.1    Finger, D.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.