메뉴 건너뛰기




Volumn 24, Issue 8, 2006, Pages 1541-1548

The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

Author keywords

Ambulatory blood pressure measurement; Blood pressure; Home monitoring; Hypertension; Self measurements

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD PRESSURE; BLOOD PRESSURE MONITORING; CONTROLLED STUDY; CORRELATION ANALYSIS; DIASTOLIC BLOOD PRESSURE; FEMALE; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SELF BLOOD PRESSURE MONITORING; SEX DIFFERENCE; SYSTOLIC BLOOD PRESSURE;

EID: 33746661666     PISSN: 02636352     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.hjh.0000239289.87141.b6     Document Type: Article
Times cited : (68)

References (23)
  • 1
    • 0032126006 scopus 로고    scopus 로고
    • White coat effect detected using self-monitoring of blood pressure at home: Comparison with ambulatory blood pressure
    • Stergiou GS, Zourbaki AS, Skeva II, Mountokalakis TD. White coat effect detected using self-monitoring of blood pressure at home: comparison with ambulatory blood pressure. Am J Hypertens 1998; 11:820-827.
    • (1998) Am J Hypertens , vol.11 , pp. 820-827
    • Stergiou, G.S.1    Zourbaki, A.S.2    Skeva, I.I.3    Mountokalakis, T.D.4
  • 2
    • 0142125690 scopus 로고    scopus 로고
    • The Norwegian office-, home-, and ambulatory blood pressure study (NOHA)
    • Omvik P, Gerhardsen G. The Norwegian office-, home-, and ambulatory blood pressure study (NOHA). Blood Press 2003; 12:211-219.
    • (2003) Blood Press , vol.12 , pp. 211-219
    • Omvik, P.1    Gerhardsen, G.2
  • 3
    • 0042095870 scopus 로고    scopus 로고
    • Usefulness of home blood pressure measurement in the morning in type 2 diabetic patients
    • Kamoi K, Miyakoshi M, Soda S, Kaneko S, Nakagawa O. Usefulness of home blood pressure measurement in the morning in type 2 diabetic patients. Diabetes Care 2002; 25:2218-2223.
    • (2002) Diabetes Care , vol.25 , pp. 2218-2223
    • Kamoi, K.1    Miyakoshi, M.2    Soda, S.3    Kaneko, S.4    Nakagawa, O.5
  • 4
    • 0036109721 scopus 로고    scopus 로고
    • Value of home blood pressures as predictor of target organ damage in mild arterial hypertension
    • Mule G, Caimi G, Cottone S, Nardi E, Andronico G, Piazza G, et al. Value of home blood pressures as predictor of target organ damage in mild arterial hypertension. J Cardiovasc Risk 2002; 9:123-129.
    • (2002) J Cardiovasc Risk , vol.9 , pp. 123-129
    • Mule, G.1    Caimi, G.2    Cottone, S.3    Nardi, E.4    Andronico, G.5    Piazza, G.6
  • 6
    • 0036233338 scopus 로고    scopus 로고
    • Relationship between home blood pressure and longitudinal changes in target organ damage in treated hypertensive patients
    • Tsunoda S, Kawano Y, Horio T, Okuda N, Takishita S. Relationship between home blood pressure and longitudinal changes in target organ damage in treated hypertensive patients. Hypertens Res 2002; 25:167-173.
    • (2002) Hypertens Res , vol.25 , pp. 167-173
    • Tsunoda, S.1    Kawano, Y.2    Horio, T.3    Okuda, N.4    Takishita, S.5
  • 7
    • 1642326305 scopus 로고    scopus 로고
    • Practice guidelines for primary care physicians: 2003 ESH/ESC hypertension guidelines
    • Cifkova R, Erdine S, Fagard R, Farsang C, Heagerty AM, Kiowski W, et al. Practice guidelines for primary care physicians: 2003 ESH/ESC hypertension guidelines. J Hypertens 2003; 21:1779-1786.
    • (2003) J Hypertens , vol.21 , pp. 1779-1786
    • Cifkova, R.1    Erdine, S.2    Fagard, R.3    Farsang, C.4    Heagerty, A.M.5    Kiowski, W.6
  • 8
    • 1542614346 scopus 로고    scopus 로고
    • British Hypertension Society guidelines for hypertension management 2004 (BHS-IV): Summary
    • Williams B, Poulter NR, Brown MJ, Davis M, McInnes GT, Potter JF, et al. British Hypertension Society guidelines for hypertension management 2004 (BHS-IV): summary. BMJ 2004; 328:634-640.
    • (2004) BMJ , vol.328 , pp. 634-640
    • Williams, B.1    Poulter, N.R.2    Brown, M.J.3    Davis, M.4    McInnes, G.T.5    Potter, J.F.6
  • 9
    • 0030778067 scopus 로고    scopus 로고
    • For how many days should blood pressure be measured at home in older patients before steady levels are obtained?
    • Celis H, De Cort P, Fagard R, Thijs L, Staessen JA. For how many days should blood pressure be measured at home in older patients before steady levels are obtained? J Hum Hypertens 1997; 11:673-677.
    • (1997) J Hum Hypertens , vol.11 , pp. 673-677
    • Celis, H.1    De Cort, P.2    Fagard, R.3    Thijs, L.4    Staessen, J.A.5
  • 10
    • 0344958815 scopus 로고    scopus 로고
    • How many self-measured blood pressure readings are needed to estimate hypertensive patients' 'true' blood pressure?
    • Garcia-Vera MP, Sanz J. How many self-measured blood pressure readings are needed to estimate hypertensive patients' 'true' blood pressure? J Behav Med 1999; 22:93-113.
    • (1999) J Behav Med , vol.22 , pp. 93-113
    • Garcia-Vera, M.P.1    Sanz, J.2
  • 11
    • 0023829561 scopus 로고
    • How many blood pressure measurements are enough? An application of generalizability theory to the study of blood pressure reliability
    • Llabre MM, Ironson GH, Spitzer SB, Gellman MD, Weidler DJ, Schneiderman N. How many blood pressure measurements are enough? An application of generalizability theory to the study of blood pressure reliability. Psychophysiology 1988; 25:97-106.
    • (1988) Psychophysiology , vol.25 , pp. 97-106
    • Llabre, M.M.1    Ironson, G.H.2    Spitzer, S.B.3    Gellman, M.D.4    Weidler, D.J.5    Schneiderman, N.6
  • 12
    • 2642514734 scopus 로고    scopus 로고
    • How many times should blood pressure be measured at home for better prediction of stroke risk? Ten-year follow-up results from the Ohasama study
    • Ohkubo T, Asayama K, Kikuya M, Metoki H, Hoshi H, Hashimoto J, et al. How many times should blood pressure be measured at home for better prediction of stroke risk? Ten-year follow-up results from the Ohasama study. J Hypertens 2004; 22:1099-1104.
    • (2004) J Hypertens , vol.22 , pp. 1099-1104
    • Ohkubo, T.1    Asayama, K.2    Kikuya, M.3    Metoki, H.4    Hoshi, H.5    Hashimoto, J.6
  • 13
    • 0031861524 scopus 로고    scopus 로고
    • Self-monitoring of blood pressure at home: How many measurements are needed?
    • Stergiou GS, Skeva II, Zourbaki AS, Mountokalakis TD. Self-monitoring of blood pressure at home: how many measurements are needed? J Hypertens 1998; 16:725-731.
    • (1998) J Hypertens , vol.16 , pp. 725-731
    • Stergiou, G.S.1    Skeva, I.I.2    Zourbaki, A.S.3    Mountokalakis, T.D.4
  • 14
    • 0031054512 scopus 로고    scopus 로고
    • Prediction of cardiac structure and function by repeated clinic and ambulatory blood pressure
    • Fagard RH, Staessen JA, Thijs L. Prediction of cardiac structure and function by repeated clinic and ambulatory blood pressure. Hypertension 1997; 29:22-29.
    • (1997) Hypertension , vol.29 , pp. 22-29
    • Fagard, R.H.1    Staessen, J.A.2    Thijs, L.3
  • 15
    • 0033254659 scopus 로고    scopus 로고
    • Blood pressure monitoring. Task force III: Target-organ damage, morbidity and mortality
    • Verdecchia P, Clement D, Fagard R, Palatini P, Parati G. Blood pressure monitoring. Task force III: Target-organ damage, morbidity and mortality. Blood Press Monit 1999; 4:303-317.
    • (1999) Blood Press Monit , vol.4 , pp. 303-317
    • Verdecchia, P.1    Clement, D.2    Fagard, R.3    Palatini, P.4    Parati, G.5
  • 17
    • 0033546609 scopus 로고    scopus 로고
    • Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension
    • Systolic Hypertension in Europe Trial Investigators
    • Staessen JA, Thijs L, Fagard R, O'Brien ET, Clement D, De Leeuw PW, et al. Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension. Systolic Hypertension in Europe Trial Investigators. JAMA 1999; 282:539-546.
    • (1999) JAMA , vol.282 , pp. 539-546
    • Staessen, J.A.1    Thijs, L.2    Fagard, R.3    O'Brien, E.T.4    Clement, D.5    De Leeuw, P.W.6
  • 18
    • 0037028891 scopus 로고    scopus 로고
    • Risk of cardiovascular disease in relation to achieved office and ambulatory blood pressure control in treated hypertensive subjects
    • Verdecchia P, Reboldi G, Porcellati C, Schillaci G, Pede S, Bentivoglio M, et al. Risk of cardiovascular disease in relation to achieved office and ambulatory blood pressure control in treated hypertensive subjects. J Am Coll Cardiol 2002; 39:878-885.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 878-885
    • Verdecchia, P.1    Reboldi, G.2    Porcellati, C.3    Schillaci, G.4    Pede, S.5    Bentivoglio, M.6
  • 19
    • 9144265424 scopus 로고    scopus 로고
    • Home versus Office blood pressure MEasurements: Reduction of Unnecessary treatment Study: rationale and study design of the HOMERUS trial
    • Verberk WJ, Kroon AA, Kessels AG, Dirksen C, Nelemans PJ, Lenders JW, et al. Home versus Office blood pressure MEasurements: Reduction of Unnecessary treatment Study: rationale and study design of the HOMERUS trial. Blood Press 2003; 12:326-333.
    • (2003) Blood Press , vol.12 , pp. 326-333
    • Verberk, W.J.1    Kroon, A.A.2    Kessels, A.G.3    Dirksen, C.4    Nelemans, P.J.5    Lenders, J.W.6
  • 20
    • 1842426223 scopus 로고    scopus 로고
    • Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: The Omron HEM-705CP, Philips HP5332, and Nissei DS-175
    • O'Brien E, Mee F, Atkins N, Thomas M. Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175. Blood Press Monit 1996; 1:55-61.
    • (1996) Blood Press Monit , vol.1 , pp. 55-61
    • O'Brien, E.1    Mee, F.2    Atkins, N.3    Thomas, M.4
  • 21
    • 12444277817 scopus 로고    scopus 로고
    • European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement
    • O'Brien E, Asmar R, Beilin L, Imai Y, Mallion JM, ManciaG, et al. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens 2003; 21:821-848.
    • (2003) J Hypertens , vol.21 , pp. 821-848
    • O'Brien, E.1    Asmar, R.2    Beilin, L.3    Imai, Y.4    Mallion, J.M.5    Mancia, G.6
  • 23
    • 0033932377 scopus 로고    scopus 로고
    • User procedure for self-measurement of blood pressure
    • First International Consensus Conference on Self Blood Pressure Measurement
    • Mengden T, Chamontin B, Phong Chau N, Luis Palma Gamiz J, Chanudet X. User procedure for self-measurement of blood pressure. First International Consensus Conference on Self Blood Pressure Measurement. Blood Press Monit 2000; 5:111-129.
    • (2000) Blood Press Monit , vol.5 , pp. 111-129
    • Mengden, T.1    Chamontin, B.2    Phong Chau, N.3    Luis Palma Gamiz, J.4    Chanudet, X.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.