메뉴 건너뛰기




Volumn 32, Issue 3, 2006, Pages 241-249

Structural optimization system based on trabecular bone surface adaptation

Author keywords

Biomechanics; Optimization; Structural analysis; Trabecular bone structure

Indexed keywords

ALGORITHMS; FINITE ELEMENT METHOD; OPTIMIZATION; STRUCTURAL ANALYSIS; TOPOLOGY;

EID: 33746640112     PISSN: 1615147X     EISSN: 16151488     Source Type: Journal    
DOI: 10.1007/s00158-006-0027-9     Document Type: Article
Times cited : (40)

References (12)
  • 1
    • 0036889272 scopus 로고    scopus 로고
    • Functional adaptation of cancellous bone in human proximal femur predicted by trabecular surface remodeling simulation toward uniform stress state
    • Adachi T, Tomita Y (2002) Functional adaptation of cancellous bone in human proximal femur predicted by trabecular surface remodeling simulation toward uniform stress state. J Biomech 35:1541-1551
    • (2002) J Biomech , vol.35 , pp. 1541-1551
    • Adachi, T.1    Tomita, Y.2
  • 4
    • 0034621881 scopus 로고    scopus 로고
    • Effects of mechanical forces on maintenance and adaptation of form in trabecular bone
    • Huiskes HWJ et al (2000) Effects of mechanical forces on maintenance and adaptation of form in trabecular bone. Nature 404:704-706
    • (2000) Nature , vol.404 , pp. 704-706
    • Huiskes, H.W.J.1
  • 5
    • 33746614237 scopus 로고
    • Review of constitutive models for living tissues
    • Kowalczyk P (1991) Review of constitutive models for living tissues. Mech Teor Stosow 29:333-353
    • (1991) Mech Teor Stosow , vol.29 , pp. 333-353
    • Kowalczyk, P.1
  • 6
    • 0036441710 scopus 로고    scopus 로고
    • Modelling of bone adaptation based on an optimal response hypothesis
    • Lekszycki T (2002) Modelling of bone adaptation based on an optimal response hypothesis. Meccanica 37:343-354
    • (2002) Meccanica , vol.37 , pp. 343-354
    • Lekszycki, T.1
  • 7
    • 0033811123 scopus 로고    scopus 로고
    • High resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone
    • Niebur GL, Feldstein MJ, Yuen JC, Chen TJ, Keaveny TM (2000) High resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone. J Biomech 33:1575-1583
    • (2000) J Biomech , vol.33 , pp. 1575-1583
    • Niebur, G.L.1    Feldstein, M.J.2    Yuen, J.C.3    Chen, T.J.4    Keaveny, T.M.5
  • 10
    • 1142264037 scopus 로고    scopus 로고
    • Examples of density, orientation and shape optimal 2D-design for stiffness and/or strength with orthotropic materials
    • Pedersen P (2004) Examples of density, orientation and shape optimal 2D-design for stiffness and/or strength with orthotropic materials. Struct Multidisc Optim 26:37-49
    • (2004) Struct Multidisc Optim , vol.26 , pp. 37-49
    • Pedersen, P.1
  • 12
    • 0036978681 scopus 로고    scopus 로고
    • A 3-dimensional computer model to simulate trabecular bone metabolism
    • Ruimerman R et al (2003) A 3-dimensional computer model to simulate trabecular bone metabolism. Biorheology 40:315-320
    • (2003) Biorheology , vol.40 , pp. 315-320
    • Ruimerman, R.1