메뉴 건너뛰기




Volumn 27, Issue 2, 2006, Pages 85-98

Heat transfer characteristics and optimum insulation thickness for Hordi roofs using a pseudo one-dimensional dynamic model

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTICS; FINITE VOLUME METHOD; HEAT RESISTANCE; HEAT TRANSFER; MATHEMATICAL MODELS; THERMAL INSULATION;

EID: 33746619169     PISSN: 01430750     EISSN: 21628246     Source Type: Journal    
DOI: 10.1080/01430750.2006.9675007     Document Type: Article
Times cited : (2)

References (15)
  • 1
    • 0003973615 scopus 로고
    • 2nd Ed., New York: John Wiley & Sons, Inc
    • Ozisik, M. N., 1993. Heat Conduction, 2nd Ed. New York:John Wiley & Sons, Inc.
    • (1993) Heat Conduction
    • Ozisik, M.N.1
  • 3
    • 0026754838 scopus 로고
    • Solar Thermal Analysis of Honeycomb Roof Cover System for Energy Conservation in an Air-Conditioned Building”
    • Kaushika, N. D., Sharma, P. K., and Padma Priya, R., 1992. “Solar Thermal Analysis of Honeycomb Roof Cover System for Energy Conservation in an Air-Conditioned Building”. Energy and Buildings, 18:45–49.
    • (1992) Energy and Buildings , vol.18 , pp. 45-49
    • Kaushika, N.D.1    Sharma, P.K.2    Padma Priya, R.3
  • 4
    • 0026705971 scopus 로고
    • Effect of Exterior Surface Colour on the Thermal Performance of Buildings”
    • Bansal, N. K., Garg, S. N., and Kothari, S., 1992. “Effect of Exterior Surface Colour on the Thermal Performance of Buildings”. Building and Environment, 27 (No. 1):31–37.
    • (1992) Building and Environment , vol.27 , Issue.1 , pp. 31-37
    • Bansal, N.K.1    Garg, S.N.2    Kothari, S.3
  • 5
    • 0027306454 scopus 로고
    • Use of Radiation Control Coatings to Reduce Building Air-Conditioning Loads”
    • Yarbrough, D. W., and Anderson, R. W., 1993. “Use of Radiation Control Coatings to Reduce Building Air-Conditioning Loads”. Energy Sources, 15 (No. 1):59–66.
    • (1993) Energy Sources , vol.15 , Issue.1 , pp. 59-66
    • Yarbrough, D.W.1    Anderson, R.W.2
  • 6
    • 0028396516 scopus 로고
    • Thermal and Mechanical Properties of Cellular Polystyrene and Polyurethane Insulation Materials Aged on a Flat Roof in Hot-Dry Climate”
    • Ozkan, E., 1994. “Thermal and Mechanical Properties of Cellular Polystyrene and Polyurethane Insulation Materials Aged on a Flat Roof in Hot-Dry Climate”. Journal of Testing and Evaluation, 22 (No. 2):149–160.
    • (1994) Journal of Testing and Evaluation , vol.22 , Issue.2 , pp. 149-160
    • Ozkan, E.1
  • 7
    • 0031997889 scopus 로고    scopus 로고
    • The Contribution of a Planted Roof to the Thermal Protection of Buildings in Greece”
    • Eumorfopoulou, E., and Aravantinos, D., 1998. “The Contribution of a Planted Roof to the Thermal Protection of Buildings in Greece”. Energy and Buildings, 27 (No. 1):29–36.
    • (1998) Energy and Buildings , vol.27 , Issue.1 , pp. 29-36
    • Eumorfopoulou, E.1    Aravantinos, D.2
  • 8
    • 0036646534 scopus 로고    scopus 로고
    • Thermal Performance of Building Roof Elements”
    • Al-Sanea, S. A., 2002. “Thermal Performance of Building Roof Elements”. Building and Environment, 37 (No. 7):665–675.
    • (2002) Building and Environment , vol.37 , Issue.7 , pp. 665-675
    • Al-Sanea, S.A.1
  • 9
    • 33746633558 scopus 로고    scopus 로고
    • Thermal Performance of Hordi Roofs in a Hot-Dry Climate”
    • Engineering Science (1), Riyadh
    • Al-Sanea, S. A., 2004. “Thermal Performance of Hordi Roofs in a Hot-Dry Climate”. Journal of King Saud University, 17:101–121. Engineering Science (1), Riyadh
    • (2004) Journal of King Saud University , vol.17 , pp. 101-121
    • Al-Sanea, S.A.1
  • 11
    • 85024219441 scopus 로고    scopus 로고
    • Saudi Arabia: private communication
    • King Abdulaziz City for Science and Technology (KACST). 2000. Riyadh Saudi Arabia private communication
    • (2000) Riyadh
  • 12
    • 2642572449 scopus 로고    scopus 로고
    • Adjustment Factors for the ASHRAE Clear-Sky Model Based on Solar-Radiation Measurements in Riyadh”
    • Al-Sanea, S. A., Zedan, M. F., and Al-Ajlan, S. A., 2004. “Adjustment Factors for the ASHRAE Clear-Sky Model Based on Solar-Radiation Measurements in Riyadh”. Applied Energy, 79:215–237.
    • (2004) Applied Energy , vol.79 , pp. 215-237
    • Al-Sanea, S.A.1    Zedan, M.F.2    Al-Ajlan, S.A.3
  • 14
    • 0035302569 scopus 로고    scopus 로고
    • Effect of Insulation Location on Thermal Performance of Building Walls under Steady Periodic Conditions”
    • Al-Sanea, S. A., and Zedan, M. F., 2001. “Effect of Insulation Location on Thermal Performance of Building Walls under Steady Periodic Conditions”. International Journal of Ambient Energy, 22 (No. 2):59–72.
    • (2001) International Journal of Ambient Energy , vol.22 , Issue.2 , pp. 59-72
    • Al-Sanea, S.A.1    Zedan, M.F.2
  • 15
    • 0035302555 scopus 로고    scopus 로고
    • Effect of Insulation Location on Initial Transient Thermal Response of Building Walls”
    • Al-Sanea, S. A., and Zedan, M. F., 2001. “Effect of Insulation Location on Initial Transient Thermal Response of Building Walls”. Journal of Thermal Envelope and Building Science, 24 (No. 4):275–300.
    • (2001) Journal of Thermal Envelope and Building Science , vol.24 , Issue.4 , pp. 275-300
    • Al-Sanea, S.A.1    Zedan, M.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.