Volumn 52, Issue 8, 2006, Pages 1612-1614

Magnesium contamination from terumo blood collection tubes [8]

Author keywords

[No Author keywords available]

Indexed keywords

DYE; FORMAZAN; HEPARIN; LITHIUM; LUBRICATING AGENT; MAGNESIUM; SILICONE; UNCLASSIFIED DRUG; XYLIDYL BLUE;

EID: 33746618324     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/clinchem.2005.064683     Document Type: Letter
Times cited : (2)

References (6)
  • 1
    • 25444478307 scopus 로고    scopus 로고
    • Immunoassay interference by a commonly used blood collection tube additive, the organosilicone surfactant Silwet L-720
    • Bowen AR, Chan Y, Ruddel ME, Hortin GL, Csako G, Demosky SJ, et al. Immunoassay interference by a commonly used blood collection tube additive, the organosilicone surfactant Silwet L-720. Clin Chem 2005;51:1874-82.
    • (2005) Clin Chem , vol.51 , pp. 1874-1882
    • Bowen, A.R.1    Chan, Y.2    Ruddel, M.E.3    Hortin, G.L.4    Csako, G.5    Demosky, S.J.6
  • 2
    • 35348894171 scopus 로고    scopus 로고
    • Evaluation of Greiner Bio-One Vacutte® tube for clinical chemistry assays using DPC Immulite®, Ortho Vitras®, and Beckman Immage®
    • Garg U, Althahabi R, Redding N, Neilan N, Faller D. Evaluation of Greiner Bio-One Vacutte® tube for clinical chemistry assays using DPC Immulite®, Ortho Vitras®, and Beckman Immage®. Clin Chem 2005;51(Suppl 6):A131.
    • (2005) Clin Chem , vol.51 , Issue.SUPPL. 6
    • Garg, U.1    Althahabi, R.2    Redding, N.3    Neilan, N.4    Faller, D.5
  • 3
    • 33746654724 scopus 로고    scopus 로고
    • Investigation of immunoassay interference from reformulated blood collection tubes
    • Chan Y, Bowen RA, Remaley AT. Investigation of immunoassay interference from reformulated blood collection tubes. Clin Chem 2005; 51(Suppl 6):A145.
    • (2005) Clin Chem , vol.51 , Issue.SUPPL. 6
    • Chan, Y.1    Bowen, R.A.2    Remaley, A.T.3
  • 4
    • 0141829887 scopus 로고    scopus 로고
    • Elevated results in a vitamin B12 assay when using serum separator blood collection tubes
    • Lowrey I, Smith G. Elevated results in a vitamin B12 assay when using serum separator blood collection tubes. Ann Clin Biochem 2003;40: 560-2.
    • (2003) Ann Clin Biochem , vol.40 , pp. 560-562
    • Lowrey, I.1    Smith, G.2
  • 5
    • 0035023630 scopus 로고    scopus 로고
    • Stability of therapeutic drugs in serum collected in vacutainer serum separator tube containing new gel (SST II)
    • Bush V, Blennerhasset J, Wells A, Dasgupta A. Stability of therapeutic drugs in serum collected in vacutainer serum separator tube containing new gel (SST II). Ther Drug Monit 2001; 23:259-62.
    • (2001) Ther Drug Monit , vol.23 , pp. 259-262
    • Bush, V.1    Blennerhasset, J.2    Wells, A.3    Dasgupta, A.4
  • 6
    • 0034868297 scopus 로고    scopus 로고
    • Evaluation of AVL 988/4 analyser for measurement of ionized magnesium and ionized calcium
    • Cao Z, Tongate C, Elin RJ. Evaluation of AVL 988/4 analyser for measurement of ionized magnesium and ionized calcium. Scand J Lab Invest 2001;61:389-94.
    • (2001) Scand J Lab Invest , vol.61 , pp. 389-394
    • Cao, Z.1    Tongate, C.2    Elin, R.J.3