메뉴 건너뛰기




Volumn 16, Issue 2, 2006, Pages 886-889

Implications of NbTi short-sample test results and analysis for the ITER Poloidal Field Conductor Insert (PFCI)

(24)  Zanino, R a   Bagnasco, M a   Baker, W b   Bellina, F c   Bruzzone, P d   Della Corte, A e   Ilyin, Y f   Martovetsky, N g   Mitchell, N h   Muzzi, L e   Nijhuis, A f   Nunoya, Y i   Okuno, K i   Rajainmaki, H b   Ribani, P L j   Ricci, M e   Salpietro, E b   Richard, L Savoldi a   Shikov, A k   Sytnikov, V l   more..

e ENEA   (Italy)
h ITER IT   (Japan)

Author keywords

Fusion reactors; ITER; Modeling; Superconducting coils

Indexed keywords

CALORIMETRY; COMPUTER SIMULATION; ELECTRIC COILS; ELECTRIC LOSSES; EXTRAPOLATION; NIOBIUM ALLOYS; QUENCHING;

EID: 33746611226     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2006.873318     Document Type: Conference Paper
Times cited : (7)

References (14)
  • 1
    • 2542475072 scopus 로고    scopus 로고
    • Test results on the first 50 kA NbTi full size sample for the international thermonuclear experimental reactor
    • D. Ciazynski et al., "Test results on the first 50 kA NbTi full size sample for the international thermonuclear experimental reactor," Supercond. Sci. Technol., vol. 17, pp. 155-160, 2004.
    • (2004) Supercond. Sci. Technol. , vol.17 , pp. 155-160
    • Ciazynski, D.1
  • 2
    • 22044433174 scopus 로고    scopus 로고
    • Test results of the ITER PF Insert conductor short sample in SULTAN
    • P. Bruzzone et al., "Test results of the ITER PF Insert conductor short sample in SULTAN," IEEE Trans. Appl. Supercond., vol. 15, pp. 1351-1354, 2005.
    • (2005) IEEE Trans. Appl. Supercond. , vol.15 , pp. 1351-1354
    • Bruzzone, P.1
  • 3
    • 22144496791 scopus 로고    scopus 로고
    • Current distribution measurement on the ITER-type NbTi bus bar III
    • R. Zanino et al., "Current distribution measurement on the ITER-type NbTi bus bar III," IEEE Trans. Appl. Supercond., vol. 15, pp. 1407-1410, 2005.
    • (2005) IEEE Trans. Appl. Supercond. , vol.15 , pp. 1407-1410
    • Zanino, R.1
  • 4
    • 22044438583 scopus 로고    scopus 로고
    • Preparation of the ITER poloidal field conductor insert (PFCI) test
    • _, "Preparation of the ITER poloidal field conductor insert (PFCI) test," IEEE Trans. Appl. Supercond., vol. 15, pp. 1346-1350, 2005.
    • (2005) IEEE Trans. Appl. Supercond. , vol.15 , pp. 1346-1350
  • 5
    • 0034156152 scopus 로고    scopus 로고
    • M&M: Multi-conductor mithrandir code for the simulation of thermal-hydraulic transients in super-conducting magnets
    • L. Savoldi and R. Zanino, "M&M: multi-conductor mithrandir code for the simulation of thermal-hydraulic transients in super-conducting magnets," Cryogenics, vol. 40, pp. 179-189, 2000.
    • (2000) Cryogenics , vol.40 , pp. 179-189
    • Savoldi, L.1    Zanino, R.2
  • 6
    • 0038298728 scopus 로고    scopus 로고
    • Analysis and interpretation of the full set (2000-2002) of tcs tests in conductor 1 a of the ITER central solenoid model coil
    • R. Zanino et al., "Analysis and Interpretation of the Full Set (2000-2002) of Tcs tests in conductor 1 A of the ITER central solenoid model coil," Cryogenics, vol. 43, pp. 179-197, 2003.
    • (2003) Cryogenics , vol.43 , pp. 179-197
    • Zanino, R.1
  • 7
    • 4344680383 scopus 로고    scopus 로고
    • DC performance of subsize NbTi cable-in-conduit conductors
    • R. Wesche et al., "DC performance of subsize NbTi cable-in-conduit conductors," IEEE Trans. Appl. Supercond., vol. 14, pp. 1499-1502, 2004.
    • (2004) IEEE Trans. Appl. Supercond. , vol.14 , pp. 1499-1502
    • Wesche, R.1
  • 8
    • 22044434713 scopus 로고    scopus 로고
    • DC performances of ITER NbTi Condutcors: Models vs. measurements
    • D. Ciazynski et al., "DC performances of ITER NbTi Condutcors: models vs. measurements," IEEE Trans. Appl. Supercond., vol. 15, pp. 1355-1358, 2005.
    • (2005) IEEE Trans. Appl. Supercond. , vol.15 , pp. 1355-1358
    • Ciazynski, D.1
  • 9
    • 0029259863 scopus 로고
    • A two-fluid code for the thermohydraulic transient analysis of CICC superconducting magnets
    • R. Zanino et al., "A two-fluid code for the thermohydraulic transient analysis of CICC superconducting magnets," J. Fus. Energy, vol. 14, pp. 25-40, 1995.
    • (1995) J. Fus. Energy , vol.14 , pp. 25-40
    • Zanino, R.1
  • 11
    • 12444274306 scopus 로고    scopus 로고
    • Superconductive cables current distribution analysis
    • F. Bellina et al., "Superconductive cables current distribution analysis," Fus. Eng. Des., vol. 66-68, pp. 1159-1163, 2003.
    • (2003) Fus. Eng. Des. , vol.66-68 , pp. 1159-1163
    • Bellina, F.1
  • 12
    • 4344647457 scopus 로고    scopus 로고
    • Electromagnetic analysis of superconducting cables and joints in transient regime
    • _, "Electromagnetic analysis of superconducting cables and joints in transient regime," IEEE Trans. Appl. Supercond., vol. 14, pp. 1356-1359, 2004.
    • (2004) IEEE Trans. Appl. Supercond. , vol.14 , pp. 1356-1359
  • 13
    • 27744432277 scopus 로고    scopus 로고
    • Sudden take-off in a large NbTi conductor: Not a stability issue
    • R. Wesche et al., "Sudden take-off in a large NbTi conductor: not a stability issue," Adv. Cryo Eng., vol. 50 B, pp. 820-827, 2004.
    • (2004) Adv. Cryo Eng. , vol.50 B , pp. 820-827
    • Wesche, R.1
  • 14
    • 33746602172 scopus 로고    scopus 로고
    • Anomalies on V-I characteristic of NbTi cable-in-conduit conductors
    • Venice, Italy
    • P. Bruzzone et al., "Anomalies on V-I characteristic of NbTi cable-in-conduit conductors," presented at the SOFT 2004, Venice, Italy.
    • SOFT 2004
    • Bruzzone, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.