Volumn 33, Issue 8, 2006, Pages 3006-3017

Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners

Author keywords

Computed tomography; Lung nodule; Phantoms

Indexed keywords

BIOLOGICAL ORGANS; CALCITE; CALCIUM CARBONATE; COMPUTER AIDED DIAGNOSIS; HARDENING; MEDICAL COMPUTING; PHANTOMS; SCANNING; TISSUE;

EID: 33746592052     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2219332     Document Type: Article
Times cited : (37)

References (13)
  • 1
    • 0025238446 scopus 로고
    • Radiological evaluation of the solitary pulmonary nodule
    • W. R. Webb, "Radiological evaluation of the solitary pulmonary nodule," AJR, Am. J. Roentgenol. 154, 701-708 (1990).
    • (1990) AJR, Am. J. Roentgenol. , vol.154 , pp. 701-708
    • Webb, W.R.1
  • 2
    • 0020511063 scopus 로고
    • Experimental lung nodule model: CT numbers, nodule size and actual calcium content
    • R. D. Tarver, R. W. Holden, and J. H. Ellis, "Experimental lung nodule model: CT numbers, nodule size and actual calcium content," J. Comput. Assist. Tomogr. 7, 402-406 (1983).
    • (1983) J. Comput. Assist. Tomogr. , vol.7 , pp. 402-406
    • Tarver, R.D.1    Holden, R.W.2    Ellis, J.H.3
  • 3
    • 0021082657 scopus 로고
    • A standard phantom for quantitative CT analysis of pulmonary nodules
    • E. A. Zerhouni et al., "A standard phantom for quantitative CT analysis of pulmonary nodules," Radiology 149, 767-773 (1983).
    • (1983) Radiology , vol.149 , pp. 767-773
    • Zerhouni, E.A.1
  • 4
    • 0022480622 scopus 로고
    • CT of the pulmonary nodule: A cooperative study
    • E. A. Zerhouni et al., "CT of the pulmonary nodule: A cooperative study," Radiology 160, 319-327 (1986).
    • (1986) Radiology , vol.160 , pp. 319-327
    • Zerhouni, E.A.1
  • 6
    • 0025797282 scopus 로고
    • CT evaluation of solitary pulmonary nodules: Value of 185-H reference phantom
    • S. J. Swensen, G. F. Harms, R. L. Morin, and J. L. Myers, "CT evaluation of solitary pulmonary nodules: Value of 185-H reference phantom," AJR, Am. J. Roentgenol. 156, 925-929 (1991).
    • (1991) AJR, Am. J. Roentgenol , vol.156 , pp. 925-929
    • Swensen, S.J.1    Harms, G.F.2    Morin, R.L.3    Myers, J.L.4
  • 7
    • 0025727464 scopus 로고
    • Solitary pulmonary nodules: Comparison of classification with standard, thin-section and reference phantom CT
    • A. Khan, P. G. Herman, P. Vorwerk, P. Stevens, K. A. Rojas, and M. Garver, "Solitary pulmonary nodules: Comparison of classification with standard, thin-section and reference phantom CT," Radiology 179, 477-481 (1991).
    • (1991) Radiology , vol.179 , pp. 477-481
    • Khan, A.1    Herman, P.G.2    Vorwerk, P.3    Stevens, P.4    Rojas, K.A.5    Garver, M.6
  • 9
    • 10444244070 scopus 로고    scopus 로고
    • Final results of the lung screening study, a randomized feasibility study of spiral CT versus chest x-ray screening for lung cancer
    • J. Gohagan et al., "Final results of the lung screening study, a randomized feasibility study of spiral CT versus chest x-ray screening for lung cancer," Lung Cancer 47, 9-15 (2005).
    • (2005) Lung Cancer , vol.47 , pp. 9-15
    • Gohagan, J.1
  • 10
    • 7844225869 scopus 로고
    • Physical aspects of irradiation
    • Handbook 85
    • National Bureau of Standards, "Physical aspects of irradiation," ICRU Report 10b. Handbook 85 (1964).
    • (1964) ICRU Report 10b
  • 11
    • 0025349284 scopus 로고
    • Measurement of pulmonary parenchymal attenuation: Use of spirometric gating with quantitative CT
    • W. A. Kalender, R. Rienmuller, W. Seissler, J. Behr, M. Welke, and H. Fichte, "Measurement of pulmonary parenchymal attenuation: Use of spirometric gating with quantitative CT," Radiology 175, 265-268 (1990).
    • (1990) Radiology , vol.175 , pp. 265-268
    • Kalender, W.A.1    Rienmuller, R.2    Seissler, W.3    Behr, J.4    Welke, M.5    Fichte, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.