메뉴 건너뛰기




Volumn 94, Issue 2, 2006, Pages 156-166

Global endometrial ablation: A modern day solution to an age-old problem

Author keywords

Dysfunctional uterine bleeding; Endometrial ablation; Gynecologic surgery

Indexed keywords

ARTICLE; BRADYCARDIA; BURN; ELECTROLYTE DISTURBANCE; ENDOMETRIUM ABLATION; HORMONAL THERAPY; HUMAN; HYPERVOLEMIA; HYSTERECTOMY; LACERATION; MENORRHAGIA; MENSTRUATION; PRIORITY JOURNAL; ROLLERBALL ENDOMETRIAL ABLATION; SENESCENCE; SURGEON; SURGICAL INSTRUMENT; UTERINE CERVIX; UTERINE COMPLICATION; UTERUS CAVITY; UTERUS PERFORATION;

EID: 33746582669     PISSN: 00207292     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijgo.2006.05.007     Document Type: Article
Times cited : (7)

References (33)
  • 3
    • 0020696186 scopus 로고
    • Hysteroscopic management of intrauterine lesions and intractable uterine bleeding
    • DeChernery A., and Polan M.L. Hysteroscopic management of intrauterine lesions and intractable uterine bleeding. Obstet Gynecol 61 (1983) 392-396
    • (1983) Obstet Gynecol , vol.61 , pp. 392-396
    • DeChernery, A.1    Polan, M.L.2
  • 4
    • 0002713238 scopus 로고
    • The development of a new hysteroscopic resectoscope and its clinical applications on transcervical resection (TCR) and endometrial ablation (EA)
    • Lin B.L., Miyamoto M., Horikoshi H., Nakamura H., and Iwata Y. The development of a new hysteroscopic resectoscope and its clinical applications on transcervical resection (TCR) and endometrial ablation (EA). Jpn J Gynecol Obstet Endosc 4 (1988) 56-61
    • (1988) Jpn J Gynecol Obstet Endosc , vol.4 , pp. 56-61
    • Lin, B.L.1    Miyamoto, M.2    Horikoshi, H.3    Nakamura, H.4    Iwata, Y.5
  • 5
    • 0024330028 scopus 로고
    • Electrocoagulation of the endometrium with the ball-end resectoscope
    • Vancaillie T.G. Electrocoagulation of the endometrium with the ball-end resectoscope. Obstet Gynecol 74 (1989) 425-427
    • (1989) Obstet Gynecol , vol.74 , pp. 425-427
    • Vancaillie, T.G.1
  • 7
    • 84921430547 scopus 로고    scopus 로고
    • Endometrial resection and ablation versus hysterectomy for heavy menstrual bleeding
    • Lethaby A., Shepperd S., Cooke I., and Farquhar C. Endometrial resection and ablation versus hysterectomy for heavy menstrual bleeding. Cochrane Database Syst Rev (2005) 1
    • (2005) Cochrane Database Syst Rev , pp. 1
    • Lethaby, A.1    Shepperd, S.2    Cooke, I.3    Farquhar, C.4
  • 8
    • 0025183484 scopus 로고
    • Assessment of menstrual blood loss using a pictorial chart
    • Higham J.M., O'Brien P.M.S., and Shaw R.W. Assessment of menstrual blood loss using a pictorial chart. Br J Obstet Gynaecol 97 (1990) 734-739
    • (1990) Br J Obstet Gynaecol , vol.97 , pp. 734-739
    • Higham, J.M.1    O'Brien, P.M.S.2    Shaw, R.W.3
  • 11
    • 0034101123 scopus 로고    scopus 로고
    • Thermal balloon and rollerball ablation to treat menorrhagia: two year results of a multicenter, prospective randomized clinical trial
    • Grainger D.A., Tjaden B.L., Rowland C., and Meyer W.R. Thermal balloon and rollerball ablation to treat menorrhagia: two year results of a multicenter, prospective randomized clinical trial. J Am Assoc Gynecol Laparosc 7 (2000) 175-179
    • (2000) J Am Assoc Gynecol Laparosc , vol.7 , pp. 175-179
    • Grainger, D.A.1    Tjaden, B.L.2    Rowland, C.3    Meyer, W.R.4
  • 12
    • 0035106571 scopus 로고    scopus 로고
    • Three year comparison of thermal balloon and rollerball ablation in treatment of menorrhagia
    • Loffer F.D. Three year comparison of thermal balloon and rollerball ablation in treatment of menorrhagia. J Am Assoc Gynecol Laparosc 8 (2001) 48-54
    • (2001) J Am Assoc Gynecol Laparosc , vol.8 , pp. 48-54
    • Loffer, F.D.1
  • 13
    • 0036827137 scopus 로고    scopus 로고
    • Five-year follow up of patients participating in a randomized trial of uterine balloon therapy versus rollerball ablation for treatment of menorrhagia
    • Loffer F.D., and Grainger D. Five-year follow up of patients participating in a randomized trial of uterine balloon therapy versus rollerball ablation for treatment of menorrhagia. J Am Assoc Gynecol Laparosc 9 (2002) 429-435
    • (2002) J Am Assoc Gynecol Laparosc , vol.9 , pp. 429-435
    • Loffer, F.D.1    Grainger, D.2
  • 14
    • 1942539866 scopus 로고    scopus 로고
    • Efficacy and satisfaction rate comparing endometrial ablation by rollerball electrocoagulation to uterine balloon thermal ablation in a randomized controlled trial
    • van Zon-Rabelink I.A., Vleugels M.P., Merkus H.M., and Graaf R. Efficacy and satisfaction rate comparing endometrial ablation by rollerball electrocoagulation to uterine balloon thermal ablation in a randomized controlled trial. Eur J Obstet Gynecol Reprod Biol 114 (2004) 97-103
    • (2004) Eur J Obstet Gynecol Reprod Biol , vol.114 , pp. 97-103
    • van Zon-Rabelink, I.A.1    Vleugels, M.P.2    Merkus, H.M.3    Graaf, R.4
  • 15
    • 0041325155 scopus 로고    scopus 로고
    • Endometrial ablation by rollerball electrocoagulation compared to uterine balloon thermal ablation technical and safety aspects
    • van Zon-Rabelink I.A., Vleugels M.P., Merkus H.M., and Graaf R. Endometrial ablation by rollerball electrocoagulation compared to uterine balloon thermal ablation technical and safety aspects. Eur J Obstet Gynecol Reprod Biol 110 (2003) 220-223
    • (2003) Eur J Obstet Gynecol Reprod Biol , vol.110 , pp. 220-223
    • van Zon-Rabelink, I.A.1    Vleugels, M.P.2    Merkus, H.M.3    Graaf, R.4
  • 17
    • 0034750863 scopus 로고    scopus 로고
    • A multicenter evaluation of endometrial ablation by Hydro ThermAblator and rollerball for treatment of menorrhagia
    • Corson S.L. A multicenter evaluation of endometrial ablation by Hydro ThermAblator and rollerball for treatment of menorrhagia. J Am Assoc Gynecol Laparosc 8 (2001) 359-378
    • (2001) J Am Assoc Gynecol Laparosc , vol.8 , pp. 359-378
    • Corson, S.L.1
  • 18
    • 0347364676 scopus 로고    scopus 로고
    • Evaluation of HydroThermAblator and rollerball endometrial ablation for menorrhagia 3 years after treatment
    • Goldrath N.H. Evaluation of HydroThermAblator and rollerball endometrial ablation for menorrhagia 3 years after treatment. J Am Assoc Gynecol Laparosc 10 (2003) 505-511
    • (2003) J Am Assoc Gynecol Laparosc , vol.10 , pp. 505-511
    • Goldrath, N.H.1
  • 19
    • 4444318894 scopus 로고    scopus 로고
    • Hysterscopic and nonhysteroscopic endometrial ablation
    • Vilos G.A. Hysterscopic and nonhysteroscopic endometrial ablation. Obstet Gynecol Clin North Am 31 (2004) 687-704
    • (2004) Obstet Gynecol Clin North Am , vol.31 , pp. 687-704
    • Vilos, G.A.1
  • 21
    • 0014948576 scopus 로고
    • Preliminary observations of cryoablation of the endometrium
    • Droegemueller W., Greer B.E., and Makowski E.L. Preliminary observations of cryoablation of the endometrium. Am J Obstet Gynecol 107 (1970) 958-961
    • (1970) Am J Obstet Gynecol , vol.107 , pp. 958-961
    • Droegemueller, W.1    Greer, B.E.2    Makowski, E.L.3
  • 22
    • 0016220123 scopus 로고
    • An estimation of tissue damage and thermal history in the cryolesion
    • Smith J.J., and Fraser J. An estimation of tissue damage and thermal history in the cryolesion. Cryobiology 11 (1974) 139-147
    • (1974) Cryobiology , vol.11 , pp. 139-147
    • Smith, J.J.1    Fraser, J.2
  • 23
    • 0012394463 scopus 로고    scopus 로고
    • A randomized study comparing endometrial cryoablation and rollerball electroablation for treatment of dysfunctional uterine bleeding
    • Dubela A.J., Heppard M.C., Soderstrom R.M., and Townsend D.M. A randomized study comparing endometrial cryoablation and rollerball electroablation for treatment of dysfunctional uterine bleeding. J Am Assoc Gynecol Laparosc 10 (2003) 17-26
    • (2003) J Am Assoc Gynecol Laparosc , vol.10 , pp. 17-26
    • Dubela, A.J.1    Heppard, M.C.2    Soderstrom, R.M.3    Townsend, D.M.4
  • 24
    • 0037342224 scopus 로고    scopus 로고
    • Durability of treatment effects after endometrial cryoablation versus rollerball electroablation for abnormal uterine bleeding: two year results of a multicenter randomized trial
    • Townsend D.E., Dubela A.J., and Wilkes M.M. Durability of treatment effects after endometrial cryoablation versus rollerball electroablation for abnormal uterine bleeding: two year results of a multicenter randomized trial. Am J Obstet Gynecol 188 (2003) 699-701
    • (2003) Am J Obstet Gynecol , vol.188 , pp. 699-701
    • Townsend, D.E.1    Dubela, A.J.2    Wilkes, M.M.3
  • 25
    • 0036827135 scopus 로고    scopus 로고
    • A randomized, multicenter trial of safety and efficacy of the NovaSure System in the treatment of menorrhagia
    • Cooper J., Gimpelson R., Laberge P., Galen D., Garza-Leal J.G., Scott J., et al. A randomized, multicenter trial of safety and efficacy of the NovaSure System in the treatment of menorrhagia. J Am Assoc Gynecol Laparosc 9 (2002) 418-428
    • (2002) J Am Assoc Gynecol Laparosc , vol.9 , pp. 418-428
    • Cooper, J.1    Gimpelson, R.2    Laberge, P.3    Galen, D.4    Garza-Leal, J.G.5    Scott, J.6
  • 26
    • 4844225775 scopus 로고    scopus 로고
    • Randomized controlled trial of bipolar radio-frequency endometrial ablation and balloon endometrial ablation
    • Bongers M.Y., Bourdrez P., Mol B.W.J., Heintz A.P.M., and Brolmann H.A. Randomized controlled trial of bipolar radio-frequency endometrial ablation and balloon endometrial ablation. Br J Obstet Gynaecol 111 (2004) 1005-1102
    • (2004) Br J Obstet Gynaecol , vol.111 , pp. 1005-1102
    • Bongers, M.Y.1    Bourdrez, P.2    Mol, B.W.J.3    Heintz, A.P.M.4    Brolmann, H.A.5
  • 27
    • 0029151622 scopus 로고
    • Microwaves for menorrhagia: a new fast technique for endometrial ablation
    • Sharp N.C., Cronin N., Feldberg I., Evans M., Hodgson D., and Ellis S. Microwaves for menorrhagia: a new fast technique for endometrial ablation. Lancet 346 (1995) 1003-1004
    • (1995) Lancet , vol.346 , pp. 1003-1004
    • Sharp, N.C.1    Cronin, N.2    Feldberg, I.3    Evans, M.4    Hodgson, D.5    Ellis, S.6
  • 28
    • 4444264288 scopus 로고    scopus 로고
    • Microwave endometrial ablation versus rollerball electroablation for menorrhagia: a multicenter randomized trial
    • Cooper J.M., Anderson T.L., Fortin C.A., Jack S.A., and Plentl M.B. Microwave endometrial ablation versus rollerball electroablation for menorrhagia: a multicenter randomized trial. J Am Assoc Gynecol Laparosc 11 (2004) 394-403
    • (2004) J Am Assoc Gynecol Laparosc , vol.11 , pp. 394-403
    • Cooper, J.M.1    Anderson, T.L.2    Fortin, C.A.3    Jack, S.A.4    Plentl, M.B.5
  • 29
    • 0033610761 scopus 로고    scopus 로고
    • Comparison of microwave endometrial ablation and transcervical resection of the endometrium for treatment of heavy menstrual loss: a randomized trial
    • Cooper K.G., Bain C., and Parkin D. Comparison of microwave endometrial ablation and transcervical resection of the endometrium for treatment of heavy menstrual loss: a randomized trial. Lancet 354 (1999) 1859-1863
    • (1999) Lancet , vol.354 , pp. 1859-1863
    • Cooper, K.G.1    Bain, C.2    Parkin, D.3
  • 30
    • 0036270552 scopus 로고    scopus 로고
    • Microwave endometrial ablation versus endometrial resection: a randomized controlled trial
    • Bain C., Cooper K.G., and Parkin D.E. Microwave endometrial ablation versus endometrial resection: a randomized controlled trial. Obstet Gynecol 99 (2002) 983-987
    • (2002) Obstet Gynecol , vol.99 , pp. 983-987
    • Bain, C.1    Cooper, K.G.2    Parkin, D.E.3
  • 31
    • 85027237122 scopus 로고    scopus 로고
    • Microwave endometrial ablation compared with pretreatment options
    • Fortin C.A., and Fontaine J. Microwave endometrial ablation compared with pretreatment options. J Am Assoc Gynecol Laparosc 9 (2002) S19
    • (2002) J Am Assoc Gynecol Laparosc , vol.9
    • Fortin, C.A.1    Fontaine, J.2
  • 33
    • 85027233556 scopus 로고    scopus 로고
    • Essure sterilization after microwave ablation
    • Glazerman L.R. Essure sterilization after microwave ablation. J Am Assoc Gynecol Laparosc 12 (2005) S118
    • (2005) J Am Assoc Gynecol Laparosc , vol.12
    • Glazerman, L.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.