메뉴 건너뛰기




Volumn 12, Issue , 2006, Pages 669-692

Building thermal performance simulation with direct evaporative cooling by water spray vaporization

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; EVAPORATION; EVAPORATIVE COOLING SYSTEMS; MATHEMATICAL MODELS;

EID: 33746573334     PISSN: 10789669     EISSN: None     Source Type: Journal    
DOI: 10.1080/10789669.2006.10391200     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 0003513483 scopus 로고
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., chapter 47, Evaporative air cooling
    • ASHRAE. 1995. 1995 ASHRAE Handbook—Applications Atlanta:American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. chapter 47, Evaporative air cooling
    • (1995) 1995 ASHRAE Handbook—Applications
  • 2
    • 0004189983 scopus 로고    scopus 로고
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc
    • ASHRAE. 1996. Psychrometrics—Theory and Practice Atlanta:American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (1996) Psychrometrics—Theory and Practice
  • 3
  • 4
    • 0020612245 scopus 로고
    • Evaporation and combustion of sprays
    • Faeth, G. M., 1983. Evaporation and combustion of sprays. Prog. Energy Combust. Sci., 9:1–76.
    • (1983) Prog. Energy Combust. Sci. , vol.9 , pp. 1-76
    • Faeth, G.M.1
  • 5
    • 0037379797 scopus 로고    scopus 로고
    • The droplet number moments approach to spray modeling: The development of heat and mass transfer sub-models
    • Beck, J. C., and Watkins, A. P., 2003. The droplet number moments approach to spray modeling:The development of heat and mass transfer sub-models. International Journal of Heat and Mass Flow, 24:242–59.
    • (2003) International Journal of Heat and Mass Flow , vol.24 , pp. 242-259
    • Beck, J.C.1    Watkins, A.P.2
  • 6
    • 0027949636 scopus 로고
    • Induced air velocity within droplets driven sprays
    • Ghosh, S., and Hunt, J. C. R., 1994. Induced air velocity within droplets driven sprays. Proc. R. Soc. Lond., 444:105–27.
    • (1994) Proc. R. Soc. Lond. , vol.444 , pp. 105-127
    • Ghosh, S.1    Hunt, J.C.R.2
  • 8
    • 33746539100 scopus 로고    scopus 로고
    • Brazil/SC: Program of Post Graduation in Civil Engineering, Federal University of Santa Catarina., (in Portuguese)
    • Silva, A. C. S. B., 2004. Simulação de Resfriamento Evaporativo por Microaspersão D'Ãgua, PhD thesis Brazil/SC:Program of Post Graduation in Civil Engineering, Federal University of Santa Catarina. (in Portuguese)
    • (2004) Simulação de Resfriamento Evaporativo por Microaspersão D'Ãgua
    • Silva, A.C.S.B.1
  • 12
    • 0022113297 scopus 로고
    • Measurements and predictions of the structure of evaporating sprays
    • Solomon, A. S. P., Shuen, J.-S., Zhang, Q.-F., and Faeth, G. M., 1985. Measurements and predictions of the structure of evaporating sprays. J. of Heat Transfer, 107:679–86.
    • (1985) J. of Heat Transfer , vol.107 , pp. 679-686
    • Solomon, A.S.P.1    Shuen, J.-S.2    Zhang, Q.-F.3    Faeth, G.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.