메뉴 건너뛰기




Volumn 2005, Issue , 2005, Pages 1-5

The similitude power detection on single-phase-to-ground fault in the non-solidly grounded system

Author keywords

Identification of faulted line; Non solidly grounded system; Relative coefficient; Single phase to ground fault; The similitude power

Indexed keywords

IDENTIFICATION OF FAULTED LINE; NON-SOLIDLY GROUNDED SYSTEM; RELATIVE COEFFICIENT; SINGLE-PHASE-TO-GROUND FAULT; THE SIMILITUDE POWER; SIMILITUDE POWER;

EID: 33746479073     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/TDC.2005.1547081     Document Type: Conference Paper
Times cited : (6)

References (15)
  • 1
    • 0032188351 scopus 로고
    • Transmission line fault location for single-phase-to-earth fault on non-direct-ground neutral system
    • Zhang Qingchao, Zhang Yao, Song Wennan, Fang Dazhong. "Transmission Line Fault Location for Single-phase-to-earth Fault On Non-direct-ground Neutral System". IEEE Trans. Power Delivery. Vol. 13 (4), pp. 1086-1092, 1988.
    • (1988) IEEE Trans. Power Delivery , vol.13 , Issue.4 , pp. 1086-1092
    • Zhang, Q.1    Zhang, Y.2    Song, W.3    Fang, D.4
  • 2
    • 0035322407 scopus 로고    scopus 로고
    • Study on feeder grounding fault protection based on zero sequence admittance
    • Zeng Xiangjun, Yin Xianggen, Zhang Zhe, Chen Deshu, Wen Minghao. "Study on feeder grounding fault protection based on zero sequence admittance". Proceedings of the CSEE. Vol. 21(4), pp. 5-10, 2001.
    • (2001) Proceedings of the CSEE. , vol.21 , Issue.4 , pp. 5-10
    • Zeng, X.1    Yin, X.2    Zhang, Z.3    Chen, D.4    Wen, M.5
  • 3
    • 0036874247 scopus 로고    scopus 로고
    • System grounding and ground-fault protection in the petrochemical industry: A need for a better understanding
    • John P. Nelson. "System Grounding and Ground-Fault Protection in the Petrochemical Industry: A Need for a Better Understanding". IEEE Trans. Industry Application. Vol. 38 (6), pp. 1633-1640, 2002.
    • (2002) IEEE Trans. Industry Application , vol.38 , Issue.6 , pp. 1633-1640
    • Nelson, J.P.1
  • 4
    • 0034172170 scopus 로고    scopus 로고
    • Transmission line fault location for double phase-to-earth fault on non-direct-ground neutral system
    • Yao Zhang, Qingchao Zhang, Wennan Song, Yixin Yu, Xiao Li. "Transmission Line Fault Location for Double Phase-to-Earth Fault on Non-Direct-Ground Neutral System". IEEE Trans. Power Delivery. Vol. 15 (2), pp. 520-524, 2000.
    • (2000) IEEE Trans. Power Delivery , vol.15 , Issue.2 , pp. 520-524
    • Zhang, Y.1    Zhang, Q.2    Song, W.3    Yu, Y.4    Li, X.5
  • 5
    • 0030193361 scopus 로고    scopus 로고
    • Wavelets: A new tool for the resonant grounded power distribution system relaying
    • Oinis Chaari, Michiel Meunier, Francoise Brouaye. "Wavelets: A new tool for the resonant grounded power distribution system relaying". IEEE Trans. Power Delivery. Vol. 11(3), pp. 1301-1308, 1996.
    • (1996) IEEE Trans. Power Delivery , vol.11 , Issue.3 , pp. 1301-1308
    • Chaari, O.1    Meunier, M.2    Brouaye, F.3
  • 6
    • 3242743881 scopus 로고    scopus 로고
    • A new criterion for earth fault line selection on wavelet packets in small current neutral grounding system
    • Wang Yaonan, Huo Bailin, Wang Hui, He Xiao. "A new criterion for earth fault line selection on wavelet packets in small current neutral grounding system". Proceedings of the CSEE. Vol. 24 (6), pp. 54-58, 2004.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.6 , pp. 54-58
    • Wang, Y.1    Huo, B.2    Wang, H.3    Xiao, H.4
  • 7
    • 0041698113 scopus 로고    scopus 로고
    • Earth fault protection in non-solidly earthed network based on transient zero sequence current comparison
    • Xue Yongduan, Feng Zuren, Xu Bingyin, Chen Yu, Li Jing. "Earth fault protection in non-solidly earthed network based on transient zero sequence current comparison". Automation of Electric Power Systems. Vol.27 (9), pp. 47-53, 2003.
    • (2003) Automation of Electric Power Systems , vol.27 , Issue.9 , pp. 47-53
    • Xue, Y.1    Feng, Z.2    Xu, B.3    Chen, Y.4    Li, J.5
  • 8
    • 0035494026 scopus 로고    scopus 로고
    • A new approach on detecting the single E-to ground fault location on power system with neutral unearthed
    • Li Mengqiu, Wang Yaonan, Wang Hui, Wu Zhengqiu. "A new approach on detecting the single E-to ground fault location on power system with neutral unearthed". Proceedings of the CSEE. Vol. 21 (10), pp. 6-9, 2001.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.10 , pp. 6-9
    • Li, M.1    Wang, Y.2    Wang, H.3    Wu, Z.4
  • 9
    • 1542399541 scopus 로고    scopus 로고
    • Application of D-S evidence theory to single-phase-to-ground fault line detection
    • Jia Qingquan, Yang Yihan, Yang Qixun. "Application of D-S evidence theory to single-phase-to-ground fault line detection". Automation of Electric Power Systems. Vol. 27 (21), pp. 35-38, 2003.
    • (2003) Automation of Electric Power Systems , vol.27 , Issue.21 , pp. 35-38
    • Jia, Q.1    Yang, Y.2    Yang, Q.3
  • 10
    • 0035079531 scopus 로고    scopus 로고
    • Elegent ground-fault solutions for impossible problems
    • David L. Swindler, Senior Member, IEEE. "Elegent Ground-Fault Solutions for Impossible Problems". IEEE Trans. industry applications. Vol. 37(1), pp. 117-128, 2001.
    • (2001) IEEE Trans. Industry Applications , vol.37 , Issue.1 , pp. 117-128
    • Swindler, D.L.1
  • 11
    • 0036124754 scopus 로고    scopus 로고
    • Grounding effects of HV and MV underground cables associated with Urban distribution
    • Jovan M. Nahman, Vladimir B. Djordjevic, and Dragutin D. Salamon. Grounding Effects of HV and MV Underground Cables Associated With Urban Distribution. IEEE Trans. power delivery. Vol. 17 (1), pp. 111-116, 2002.
    • (2002) IEEE Trans. Power Delivery , vol.17 , Issue.1 , pp. 111-116
    • Nahman, J.M.1    Djordjevic, V.B.2    Salamon, D.D.3
  • 12
    • 0033877806 scopus 로고    scopus 로고
    • The 40-Ω ground-fault phenomenon
    • John Dagenhart, Senior Member, IEEE. "The 40-Ω Ground-Fault Phenomenon". IEEE Trans. industry applications. Vol. 36 (1), pp. 30-32, 2001.
    • (2001) IEEE Trans. Industry Applications , vol.36 , Issue.1 , pp. 30-32
    • Dagenhart, J.1
  • 13
    • 0035280935 scopus 로고    scopus 로고
    • Applying CTs with digital ground relays
    • Mar./Apr.
    • Peter E. Sutherland, Senior Member, IEEE. "Applying CTs with Digital Ground Relays". IEEE Industry Applications Magazine, pp.71-79, Mar./Apr. 2001
    • (2001) IEEE Industry Applications Magazine , pp. 71-79
    • Sutherland, P.E.1
  • 14
    • 0036494687 scopus 로고    scopus 로고
    • Ground-fault currents in unit-connected generators with different elements grounding neutral
    • Marek Fulczyk, Joachim Bertsch. "Ground-Fault Currents in Unit-Connected Generators With Different Elements Grounding Neutral". IEEE Trans. Energy Conversion. Vol. 17 (1), pp. 61-66, 2002.
    • (2002) IEEE Trans. Energy Conversion. , vol.17 , Issue.1 , pp. 61-66
    • Fulczyk, M.1    Bertsch, J.2
  • 15
    • 2542446529 scopus 로고    scopus 로고
    • A correlation analysis based method to detect fault line under single phase to ground fault occurred in distribution network with current neutral grounding
    • Mao Peng, Duan Yuqian, Jiang Na. "A correlation analysis based method to detect fault line under single phase to ground fault occurred in distribution network with current neutral grounding". Power System Technology. Vol. 28 (2), pp. 36-39, 2004.
    • (2004) Power System Technology , vol.28 , Issue.2 , pp. 36-39
    • Mao, P.1    Duan, Y.2    Jiang, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.