메뉴 건너뛰기




Volumn 11, Issue 2, 2006, Pages

Label-free measurement of microbicidal gel thickness using lowcoherence interferometry

Author keywords

Drug delivery; Low coherence interferometry; Microbicides; Thickness measurements

Indexed keywords

CALIBRATION; CONTROLLED DRUG DELIVERY; DISEASES; FLUORESCENCE; INTERFEROMETRY; MEDICAL IMAGING; MICROBIOLOGY; THICKNESS MEASUREMENT; VIRUSES;

EID: 33746430150     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.2192767     Document Type: Article
Times cited : (14)

References (7)
  • 2
    • 0034949619 scopus 로고    scopus 로고
    • Distribution of topical medication in the human vagina as imaged by magnetic resonance imaging
    • DOI 10.1016/S0015-0282(01)01822-2, PII S0015028201018222
    • K. T. Barnhart, E. S. Pretorius, A. Stolpen, and D. Malamud, "Distribution of topical medication in the human vagina as imaged by magnetic resonance imaging", Fertil. Steril. 76(1), 189-195 (2001). (Pubitemid 32600980)
    • (2001) Fertility and Sterility , vol.76 , Issue.1 , pp. 189-195
    • Barnhart, K.1    Pretorius E.Scott2    Stolpen, A.3    Malamud, D.4
  • 3
    • 0034974658 scopus 로고    scopus 로고
    • Distribution of a spermicide containing Nonoxynol-9 in the vaginal canal and the upper female reproductive tract
    • K. T. Barnhart, A. Stolpen, E. S. Pretorius, and D. Malamud, "Distribution of a spermicide containing Nonoxynol-9 in the vaginal canal and the upper female reproductive tract", Hum. Reprod. 16(6), 1151-1154 (2001). (Pubitemid 32544685)
    • (2001) Human Reproduction , vol.16 , Issue.6 , pp. 1151-1154
    • Barnhart, K.T.1    Stolpen, A.2    Pretorius, E.S.3    Malamud, D.4
  • 4
    • 0242349182 scopus 로고    scopus 로고
    • Magnetic resonance imaging to determine the distribution of a vaginal gel: Before, during, and after both simulated and real intercourse
    • DOI 10.1016/S0010-7824(02)00412-2, PII S0010782402004122
    • E. S. Pretorius, K. Timbers, D. Malamud, and K. Barnhart, "Magnetic resonance imaging to determine the distribution of a vaginal gel: before, during, and after both simulated and real intercourse", Contraception 66(6), 443-451 (2002). (Pubitemid 37338061)
    • (2002) Contraception , vol.66 , Issue.6 , pp. 443-451
    • Pretorius, E.S.1    Timbers, K.2    Malamud, D.3    Barnhart, K.4
  • 5
    • 17044419113 scopus 로고    scopus 로고
    • Optical instrument for measurement of vaginal coating thickness by drug delivery formulations
    • M. H. Henderson, J. J. Peters, D. K. Walmer, G. M. Couchman, and D. F. Katz, "Optical instrument for measurement of vaginal coating thickness by drug delivery formulations", Rev. Sci. Instrum. 76(3), 034302 (2005).
    • (2005) Rev. Sci. Instrum. , vol.76 , Issue.3 , pp. 034302
    • Henderson, M.H.1    Peters, J.J.2    Walmer, D.K.3    Couchman, G.M.4    Katz, D.F.5
  • 6
    • 20544431828 scopus 로고    scopus 로고
    • Erosion of microbicide formulation coating layers: Effects of contact and shearing with vaginal fluid or semen
    • DOI 10.1002/jps.20386
    • A. R. Geonnotti, J. J. Peters, and D. F. Katz, "Erosion of microbicide formulation coating layers: Effects of contact and shearing with vaginal fluid or semen", J. Pharm. Sci. 94, 1705-1712 (2005). (Pubitemid 41360865)
    • (2005) Journal of Pharmaceutical Sciences , vol.94 , Issue.8 , pp. 1705-1712
    • Geonnotti, A.R.1    Peters, J.J.2    Katz, D.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.