메뉴 건너뛰기




Volumn 11, Issue 2, 2006, Pages

Optical recording-guided pacing to create functional line of block during ventricular fibrillation

Author keywords

Defibrillation; Optical mapping; Pacing; Ventricular fibrillation

Indexed keywords

ANIMAL; ARTICLE; CARDIOVERSION; ELECTROCARDIOGRAPHY; FLUORESCENCE MICROSCOPY; HEART PACING; HEART VENTRICLE FIBRILLATION; IN VITRO STUDY; METHODOLOGY; NERVE BLOCK; RABBIT; TREATMENT OUTCOME;

EID: 33746409190     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.2190987     Document Type: Article
Times cited : (5)

References (19)
  • 2
    • 0032417913 scopus 로고    scopus 로고
    • Can shocks timed to action potentials in low-gradient regions improve both internal and out-of-hospital defibrillation?
    • J. Jones, W. Noe, O. Tovar, Y. Lin, and W. Hsu, "Can shocks timed to action potentials in low-gradient regions improve both internal and out-of-hospital defibrillation?" J. Electrocardiol. 31, 41-44 (1998).
    • (1998) J. Electrocardiol. , vol.31 , pp. 41-44
    • Jones, J.1    Noe, W.2    Tovar, O.3    Lin, Y.4    Hsu, W.5
  • 3
    • 0036105501 scopus 로고    scopus 로고
    • Large sample test of defibrillation waveform sensitivity
    • R. A. Malkin, "Large sample test of defibrillation waveform sensitivity", J. Cardiovasc. Electrophysiol. 13, 361-370 (2002). (Pubitemid 34407601)
    • (2002) Journal of Cardiovascular Electrophysiology , vol.13 , Issue.4 , pp. 361-370
    • Malkin, R.A.1
  • 4
    • 0035008354 scopus 로고    scopus 로고
    • Critically timed auxiliary shock to weak field area lowers defibrillation threshold
    • R. G. Walker, B. H. Kenknight, and R. E. Ideker, "Critically timed auxiliary shock to weak field area lowers defibrillation threshold", J. Cardiovasc. Electrophysiol. 12, 556-562 (2001). (Pubitemid 32452612)
    • (2001) Journal of Cardiovascular Electrophysiology , vol.12 , Issue.5 , pp. 556-562
    • Walker, R.G.1    Kenknight, B.H.2    Ideker, R.E.3
  • 9
    • 0034982390 scopus 로고    scopus 로고
    • Excitable gap in canine fibrillating ventricular myocardium: Effect of subacute and chronic myocardial infarction
    • T. Taneja, G. Horvath, D. K. Racker, J. Goldberger, and A. Kadish, "Excitable gap in canine fibrillating ventricular myocardium: effect of subacute and chronic myocardial infarction", J. Cardiovasc. Electrophysiol. 12, 708-715 (2001). (Pubitemid 32506167)
    • (2001) Journal of Cardiovascular Electrophysiology , vol.12 , Issue.6 , pp. 708-715
    • Taneja, T.1    Horvath, G.2    Racker, D.K.3    Goldberger, J.4    Kadish, A.5
  • 10
    • 0030756602 scopus 로고    scopus 로고
    • Importance of location and timing of electrical stimuli in terminating sustained functional reentry in isolated swine ventricular tissues: Evidence in support of a small reentrant circuit
    • K. Kamjoo, T. Uchida, T. Ikeda, M. C. Fishbein, A. Garfinkel, J. N. Weiss, H. S. Karagueuzian, and P. S. Chen, "Importance of location and timing of electrical stimuli in terminating sustained functional reentry in isolated swine ventricular tissues: evidence in support of a small reentrant circuit", Circulation 96, 2048-2060 (1997). (Pubitemid 27400770)
    • (1997) Circulation , vol.96 , Issue.6 , pp. 2048-2060
    • Kamjoo, K.1    Uchida, T.2    Ikeda, T.3    Fishbein, M.C.4    Garfinkel, A.5    Weiss, J.N.6    Karagueuzian, H.S.7    Chen, P.-S.8
  • 11
    • 0036041658 scopus 로고    scopus 로고
    • Multiple spatially distributed stimulators and timing programs for entrainment of activation during ventricular fibrillation
    • Y. Gu and A. Patwardhan, "Multiple spatially distributed stimulators and timing programs for entrainment of activation during ventricular fibrillation", Biomed. Sci. Instrum. 38, 295-299 (2002). (Pubitemid 35005983)
    • (2002) Biomedical Sciences Instrumentation , vol.38 , pp. 295-299
    • Gu, Y.1    Patwardhan, A.2
  • 12
    • 1642342859 scopus 로고    scopus 로고
    • Restitution of Action Potential Duration during Sequential Changes in Diastolic Intervals Shows Multimodal Behavior
    • DOI 10.1161/01.RES.0000119322.87051.A9
    • R. Wu and A. Patwardhan, "Restitution of action potential duration during sequential changes in diastolic intervals shows multimodal behavior", Circ. Res. 94, 634-641 (2004). (Pubitemid 38387746)
    • (2004) Circulation Research , vol.94 , Issue.5 , pp. 634-641
    • Wu, R.1    Patwardhan, A.2
  • 13
    • 7044222809 scopus 로고    scopus 로고
    • Adaptive diastolic interval control of cardiac action potential duration alternans
    • DOI 10.1046/j.1540-8167.2004.04098.x
    • P. N. Jordan and D. J. Christini, "Adaptive diastolic interval control of cardiac action potential duration alternans", J. Cardiovasc. Electrophysiol. 15, 1177-1185 (2004). (Pubitemid 39426047)
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.10 , pp. 1177-1185
    • Jordan, P.N.1    Christini, D.J.2
  • 14
    • 0036963886 scopus 로고    scopus 로고
    • New catheter ablation techniques for the treatment of cardiac arrhythmias
    • DOI 10.1023/A:1021115804352
    • D. Keane, "New catheter ablation techniques for the treatment of cardiac arrhythmias", Card. Electrophysiol. Rev. 6, 341-348 (2002). (Pubitemid 36109106)
    • (2002) Cardiac Electrophysiology Review , vol.6 , Issue.4 , pp. 341-348
    • Keane, D.1
  • 15
    • 0348049465 scopus 로고    scopus 로고
    • Catheter Ablation of Ventricular Fibrillation in Rabbit Ventricles Treated with β-Blockers
    • DOI 10.1161/01.CIR.0000104563.12408.12
    • H. N. Pak, Y. S. Oh, Y. B. Liu, T. J. Wu, H. S. Karagueuzian, S. F. Lin, and P. S. Chen, "Catheter ablation of ventricular fibrillation in rabbit ventricles treated with beta-blockers", Circulation 108, 3149-3156 (2003). (Pubitemid 38031806)
    • (2003) Circulation , vol.108 , Issue.25 , pp. 3149-3156
    • Pak, H.-N.1    Oh, Y.-S.2    Liu, Y.-B.3    Wu, T.-J.4    Karagueuzian, H.S.5    Lin, S.-F.6    Chen, P.-S.7
  • 18
    • 4644345616 scopus 로고    scopus 로고
    • Comparison of conventional and biventricular antitachycardia pacing in a geometrically realistic model of the rabbit ventricle
    • DOI 10.1046/j.1540-8167.2004.03672.x
    • I. A. Byrd, J. M. Rogers, W. M. Smith, and A. E. Pollard, "Comparison of conventional and biventricular antitachycardia pacing in a geometrically realistic model of the rabbit ventricle", J. Cardiovasc. Electrophysiol. 15, 1066-1077 (2004). (Pubitemid 39281539)
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.9 , pp. 1066-1077
    • Byrd, I.A.1    Rogers, J.M.2    Smith, W.M.3    Pollard, A.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.