메뉴 건너뛰기




Volumn 53, Issue 3, 2006, Pages 1744-1748

Low-noise amplification of γ-ray detector signals in hostile environments

Author keywords

Charge preamplifier; Digital filtering; Gamma ray spectroscopy

Indexed keywords

CHARGE PREAMPLIFIER; DIGITAL FILTERING; GAMMA-RAY SPECTROSCOPY; HIGH PURITY GERMANIUM; LOW-NOISE AMPLIFICATION;

EID: 33746346726     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.874886     Document Type: Article
Times cited : (11)

References (8)
  • 1
    • 0029518488 scopus 로고
    • Radiation effects at cryogenic temperatures in Si-JFET, GaAs MESFET, and MOSFET devices
    • Dec.
    • M. Citterio, S. Rescia, and V. Radeka, "Radiation effects at cryogenic temperatures in Si-JFET, GaAs MESFET, and MOSFET devices," IEEE Trans. Nucl. Sci., vol. 42, no. 6, pp. 2266-2270, Dec. 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , Issue.6 , pp. 2266-2270
    • Citterio, M.1    Rescia, S.2    Radeka, V.3
  • 4
    • 0017453366 scopus 로고
    • Signal coupling from a semiconductor detector to a cold termination resistance preamplifier through a cable or a delay line transformer
    • Feb.
    • E. Gatti and P. F. Manfredi, "Signal coupling from a semiconductor detector to a cold termination resistance preamplifier through a cable or a delay line transformer," IEEE Trans. Nucl. Sci, vol. NS-25, no. 1, pp. 66-74, Feb. 1978.
    • (1978) IEEE Trans. Nucl. Sci , vol.NS-25 , Issue.1 , pp. 66-74
    • Gatti, E.1    Manfredi, P.F.2
  • 5
    • 14644437711 scopus 로고    scopus 로고
    • GERDA: A new 76Ge double beta decay experiment at Gran Sasso
    • June
    • S. Schonert, "GERDA: A new 76Ge Double Beta Decay Experiment at Gran Sasso," Nucl. Phys. B Suppl., vol. 143, pp. 567-567, June 2005.
    • (2005) Nucl. Phys. B Suppl. , vol.143 , pp. 567-567
    • Schonert, S.1
  • 6
    • 0030264652 scopus 로고    scopus 로고
    • Resolution limits of silicon detectors and electronics for soft X-ray spectroscopy at non cryogenic temperatures
    • A. Pullia and G. Bertuccio, "Resolution limits of silicon detectors and electronics for soft X-ray spectroscopy at non cryogenic temperatures," Nucl. Instrum. Meth. A, vol. 380, pp. 1-5, 1996.
    • (1996) Nucl. Instrum. Meth. A , vol.380 , pp. 1-5
    • Pullia, A.1    Bertuccio, G.2
  • 8
    • 0038612150 scopus 로고    scopus 로고
    • Simulation and analysis of pulse shapes from highly segmented HPGe detectors for the gamma-ray tracking array MARS
    • Th. Kröll and D. Bazzacco, "Simulation and analysis of pulse shapes from highly segmented HPGe detectors for the gamma-ray tracking array MARS," Nucl. Instrum. Meth. A, vol. 463, pp. 227-249, 2001.
    • (2001) Nucl. Instrum. Meth. A , vol.463 , pp. 227-249
    • Kröll, Th.1    Bazzacco, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.