Volumn 4046 LNCS, Issue , 2006, Pages 593-600

Contrast threshold of 4 full field digital mammography systems using different measurement methods

Author keywords

[No Author keywords available]

Indexed keywords

CALCIFICATION (BIOCHEMISTRY); COMPUTER SIMULATION; DETECTORS; FLAT PANEL DISPLAYS; IMAGE PROCESSING; SPURIOUS SIGNAL NOISE;

EID: 33746331717     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/11783237_80     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 0003908115 scopus 로고    scopus 로고
    • Medical imaging - The assessment of image quality
    • April
    • "Medical Imaging - The Assessment of Image Quality", ICRU Report 54, April 1996.
    • (1996) ICRU Report , vol.54
  • 2
    • 84941160875 scopus 로고    scopus 로고
    • Artinis, Medical Systems B.V.
    • User Manual CDMAM 3.4, Artinis, Medical Systems B.V.
    • User Manual CDMAM 3.4
  • 3
    • 0041386608 scopus 로고    scopus 로고
    • Development and validation of a simulation procedure to study the visibility of microcalcifications in digital mammograms
    • August
    • Carton, A.-K., Bosmans, H., Vanongeval, C., Souverijns, G., Rogge, F., Van Steen, A., Marchai, G.: Development and validation of a simulation procedure to study the visibility of microcalcifications in digital mammograms, Med. Phys. 30, August 2003, 2234-2240.
    • (2003) Med. Phys. , vol.30 , pp. 2234-2240
    • Carton, A.-K.1    Bosmans, H.2    Vanongeval, C.3    Souverijns, G.4    Rogge, F.5    Van Steen, A.6    Marchai, G.7
  • 4
    • 3142658659 scopus 로고    scopus 로고
    • Quantification of Al-equivalent thickness of just visible micro calcifications in full field digital mammograms
    • July
    • Carton, A.-K., Bosmans, H., Vandenbroucke, D., Souverijns, G., Van Ongeval, C., Dragusin, O.: "Quantification of Al-equivalent thickness of just visible micro calcifications in full field digital mammograms", Med.Phys. 31, July 2004, 2165-2176.
    • (2004) Med. Phys. , vol.31 , pp. 2165-2176
    • Carton, A.-K.1    Bosmans, H.2    Vandenbroucke, D.3    Souverijns, G.4    Van Ongeval, C.5    Dragusin, O.6
  • 5
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • Samei, E., Flynn, M. J., and Reimann, D. A.: A method for measuring the presampled MTF of digital radiographic systems using an edge test device, Med. Phys. 25, 102-113 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 8
    • 0032593780 scopus 로고    scopus 로고
    • Mammographic structure: Data preparation and spatial statistics analysis
    • K. Hanson (ed.), SPIE, Bellingham WA
    • Burgess, A.E.: "Mammographic structure: Data preparation and spatial statistics analysis", Medical Imaging 1999: Image Processing, K. Hanson (ed.), Vol.3661, 642-653, SPIE, Bellingham WA 1999.
    • (1999) Medical Imaging 1999: Image Processing , vol.3661 , pp. 642-653
    • Burgess, A.E.1
  • 9
    • 0001703782 scopus 로고    scopus 로고
    • The FROC, AFROC and DROC variants of the ROC analysis
    • Chapter 16, Edited by J. Beutel, H.L. Kundel, R.L. Van Metter (SPIE, Bellingham, WA)
    • Chakraborty, D. P.: "The FROC, AFROC and DROC variants of the ROC Analysis", Chapter 16 in Handbook of medical imaging, Physics and Psychophysics Vol. 1,Edited by J. Beutel, H.L. Kundel, R.L. Van Metter (SPIE, Bellingham, WA, 2000).
    • (2000) Handbook of Medical Imaging, Physics and Psychophysics , vol.1
    • Chakraborty, D.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.