메뉴 건너뛰기




Volumn 17, Issue 8, 2006, Pages 2113-2118

Spatial imaging with 3D capacitance measurements

Author keywords

3D Electrical capacitance tomography; 3D modelling; 3D visualization; Image reconstruction

Indexed keywords

ALGORITHMS; CAPACITANCE; COMPUTER SIMULATION; IMAGE RECONSTRUCTION; MATHEMATICAL MODELS; MEDICAL APPLICATIONS;

EID: 33746313438     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/17/8/009     Document Type: Article
Times cited : (78)

References (12)
  • 4
    • 0035421453 scopus 로고    scopus 로고
    • Electrical capacitance tomography: Image reconstruction along electrical field lines
    • Loser T, Wajman R and Mewes D 2001 Electrical capacitance tomography: image reconstruction along electrical field lines Meas. Sci. Technol. 12 1083-91
    • (2001) Meas. Sci. Technol. , vol.12 , Issue.8 , pp. 1083-1091
    • Loser, T.1    Wajman, R.2    Mewes, D.3
  • 7
    • 0036994840 scopus 로고    scopus 로고
    • A Matlab toolkit for three-dimensional electrical impedance tomography: A contribution to the EIDORS project
    • Polydorides N and Lionheart W R B 2002 A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the EIDORS project Meas. Sci. Technol. 13 1871-83
    • (2002) Meas. Sci. Technol. , vol.13 , Issue.12 , pp. 1871-1883
    • Polydorides, N.1    Lionheart, W.R.B.2
  • 9
    • 33746283483 scopus 로고    scopus 로고
    • The numerical calculation of the characteristic parameters of the electrical field in the sensor of electrical process tomography
    • Wajman R, Mazurkiewicz Ł and Banasiak R 2004 The numerical calculation of the characteristic parameters of the electrical field in the sensor of electrical process tomography 3rd Int. Symp. on Process Tomography (Poland, Lodz) pp 161-4
    • (2004) 3rd Int. Symp. on Process Tomography , pp. 161-164
  • 10
    • 0026818083 scopus 로고
    • Electrical capacitance tomography for flow imaging: System model for development of image reconstruction algorithms and design of primary sensors
    • Xie C G, Huang S M, Hoyle B S, Thorn R, Lenn C, Snowden D and Beck M S 1992 Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors IEE Proc. G 139 89-98
    • (1992) IEE Proc. , vol.139 , pp. 89-98
    • Xie, C.G.1    Huang, S.M.2    Hoyle, B.S.3    Thorn, R.4    Lenn, C.5    Snowden, D.6    Beck, M.S.7
  • 11
    • 0037271492 scopus 로고    scopus 로고
    • Image reconstruction algorithms for electrical capacitance tomography
    • Yang W Q and Peng L 2003 Image reconstruction algorithms for electrical capacitance tomography Meas. Sci. Technol. 14 R1-13
    • (2003) Meas. Sci. Technol. , vol.14 , Issue.1 , pp. 1-13
    • Yang, W.Q.1    Peng, L.2
  • 12
    • 8644225103 scopus 로고    scopus 로고
    • Image reconstruction for pressure filtration using EIDORS 3D
    • York T, Mazurkiewicz Ł, Polydorides N, Mann R and Grieve B 2003 Image reconstruction for pressure filtration using EIDORS 3D 3rd World Congress on Industrial Process Tomography (Banff) pp 559-64
    • (2003) 3rd World Congress on Industrial Process Tomography , pp. 559-564
    • York, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.