Volumn 21, Issue 5, 2006, Pages 765-770

Early Aseptic Loosening of a Total Knee Arthroplasty Due to Gore-Tex Particle-Induced Osteolysis

Author keywords

Gore Tex; knee arthroplasty; osteolysis

Indexed keywords

POLITEF;

EID: 33746296168     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2005.07.021     Document Type: Article
Times cited : (21)

References (23)
  • 2
    • 0030630986 scopus 로고    scopus 로고
    • Polyethylene wear and osteolysis following total knee replacement
    • Ayers D.C. Polyethylene wear and osteolysis following total knee replacement. Instr Course Lect 46 (1997) 205
    • (1997) Instr Course Lect , vol.46 , pp. 205
    • Ayers, D.C.1
  • 4
    • 0025282343 scopus 로고
    • Goretex prosthetic ligament vs. Kennedy ligament augmentation device in anterior cruciate ligament reconstruction. A prospective randomized 3-year follow-up of 41 cases
    • Dahlstedt L., Dalen N., and Jonsson U. Goretex prosthetic ligament vs. Kennedy ligament augmentation device in anterior cruciate ligament reconstruction. A prospective randomized 3-year follow-up of 41 cases. Acta Orthop Scand 61 (1990) 217
    • (1990) Acta Orthop Scand , vol.61 , pp. 217
    • Dahlstedt, L.1    Dalen, N.2    Jonsson, U.3
  • 5
    • 18244425091 scopus 로고    scopus 로고
    • Comparative animal study of three ligament prostheses for the replacement of the anterior cruciate and medial collateral ligament
    • Durselen L., Claes L., Ignatius A., et al. Comparative animal study of three ligament prostheses for the replacement of the anterior cruciate and medial collateral ligament. Biomaterials 17 (1996) 977
    • (1996) Biomaterials , vol.17 , pp. 977
    • Durselen, L.1    Claes, L.2    Ignatius, A.3
  • 6
    • 0035223099 scopus 로고    scopus 로고
    • Periprosthetic osteolysis with total knee arthroplasty
    • Engh G.A., and Ammeen D.J. Periprosthetic osteolysis with total knee arthroplasty. Instruc Course Lect 50 (2001) 391
    • (2001) Instruc Course Lect , vol.50 , pp. 391
    • Engh, G.A.1    Ammeen, D.J.2
  • 7
    • 0030667717 scopus 로고    scopus 로고
    • The science of reconstruction of the anterior cruciate ligament
    • Frank C.B., and Jackson D.W. The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Am 79 (1997) 1556
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1556
    • Frank, C.B.1    Jackson, D.W.2
  • 8
    • 0025783575 scopus 로고
    • Prosthetic anterior cruciate ligament
    • Friedman M.J. Prosthetic anterior cruciate ligament. Clin Sports Med 10 (1991) 499
    • (1991) Clin Sports Med , vol.10 , pp. 499
    • Friedman, M.J.1
  • 9
    • 0033971028 scopus 로고    scopus 로고
    • Current trends in anterior cruciate ligament reconstruction. Part II. Operative procedures and clinical correlations
    • Fu F.H., Bennett C.H., Ma C.B., et al. Current trends in anterior cruciate ligament reconstruction. Part II. Operative procedures and clinical correlations. Am J Sports Med 28 (2000) 124
    • (2000) Am J Sports Med , vol.28 , pp. 124
    • Fu, F.H.1    Bennett, C.H.2    Ma, C.B.3
  • 10
    • 0034519553 scopus 로고    scopus 로고
    • Follow-up of Gore-Tex artificial ligament-special emphasis on tunnel osteolysis
    • Fukubayashi T., and Ikeda K. Follow-up of Gore-Tex artificial ligament-special emphasis on tunnel osteolysis. J Long Term Eff Med Implants 10 (2000) 267
    • (2000) J Long Term Eff Med Implants , vol.10 , pp. 267
    • Fukubayashi, T.1    Ikeda, K.2
  • 11
    • 0030793029 scopus 로고    scopus 로고
    • X-ray changes after expanded polytetrafluoroethylene (Gore-Tex) interpositional arthroplasty
    • Greenberg J.A., Mosher J.F., and Fatti J.F. X-ray changes after expanded polytetrafluoroethylene (Gore-Tex) interpositional arthroplasty. J Hand Surg Am 22 (1997) 658
    • (1997) J Hand Surg Am , vol.22 , pp. 658
    • Greenberg, J.A.1    Mosher, J.F.2    Fatti, J.F.3
  • 12
    • 0029913186 scopus 로고    scopus 로고
    • Revision of failed prosthetic anterior cruciate ligament reconstruction
    • Greis P.E., and Steadman J.R. Revision of failed prosthetic anterior cruciate ligament reconstruction. Clin Orthop 325 (1996) 78
    • (1996) Clin Orthop , vol.325 , pp. 78
    • Greis, P.E.1    Steadman, J.R.2
  • 13
    • 0033729943 scopus 로고    scopus 로고
    • Evaluation and treatment of recurrent instability after anterior cruciate ligament reconstruction
    • Harner C.D., Giffin J.R., and Dunteman R.C. Evaluation and treatment of recurrent instability after anterior cruciate ligament reconstruction. J Bone Joint Surg Am 82 (2000) 1652
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1652
    • Harner, C.D.1    Giffin, J.R.2    Dunteman, R.C.3
  • 14
    • 0024504898 scopus 로고
    • Early experience with the Gore-Tex polytetrafluoroethylene anterior cruciate ligament prosthesis
    • Indelicato P.A., Pascale M.S., and Huegel M.O. Early experience with the Gore-Tex polytetrafluoroethylene anterior cruciate ligament prosthesis. Am J Sports Med 17 (1989) 52
    • (1989) Am J Sports Med , vol.17 , pp. 52
    • Indelicato, P.A.1    Pascale, M.S.2    Huegel, M.O.3
  • 15
    • 1442356127 scopus 로고    scopus 로고
    • The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years
    • Lachiewicz P.F., and Soileau E.S. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years. J Bone Joint Surg Am 86 (2004) 525
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 525
    • Lachiewicz, P.F.1    Soileau, E.S.2
  • 16
    • 0026920092 scopus 로고
    • Histologic analysis of a retrieved expanded polytetrafluoroethylene posterior cruciate ligament
    • Mantas J.P., Bloebaum R.D., and Hoffman A.A. Histologic analysis of a retrieved expanded polytetrafluoroethylene posterior cruciate ligament. J Appl Biomater 3 (1992) 183
    • (1992) J Appl Biomater , vol.3 , pp. 183
    • Mantas, J.P.1    Bloebaum, R.D.2    Hoffman, A.A.3
  • 17
    • 0028314628 scopus 로고
    • Artificial ligaments for anterior cruciate replacement. A new generation of problems
    • Moyen B., and Lerat J.L. Artificial ligaments for anterior cruciate replacement. A new generation of problems. J Bone Joint Surg Br 76 (1994) 173
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 173
    • Moyen, B.1    Lerat, J.L.2
  • 18
    • 0036704094 scopus 로고    scopus 로고
    • Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up
    • O'Rourke M.R., Callaghan J.J., Goetz D.D., et al. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up. J Bone Joint Surg Am 84 (2002) 1362
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 1362
    • O'Rourke, M.R.1    Callaghan, J.J.2    Goetz, D.D.3
  • 19
    • 0034787155 scopus 로고    scopus 로고
    • Tibial osteolysis associated with the modular tibial tray of a cemented posterior stabilized total knee replacement
    • Pagnano M.W., Scuderi G.R., and Insall J.N. Tibial osteolysis associated with the modular tibial tray of a cemented posterior stabilized total knee replacement. J Bone Joint Surg Am 83 (2001) 1545
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1545
    • Pagnano, M.W.1    Scuderi, G.R.2    Insall, J.N.3
  • 20
    • 0026694132 scopus 로고
    • The GORE-TEX anterior cruciate ligament prosthesis. A long-term follow-up
    • Paulos L.E., Rosenberg T.D., Grewe S.R., et al. The GORE-TEX anterior cruciate ligament prosthesis. A long-term follow-up. Am J Sports Med 20 (1992) 246
    • (1992) Am J Sports Med , vol.20 , pp. 246
    • Paulos, L.E.1    Rosenberg, T.D.2    Grewe, S.R.3
  • 21
    • 0029188668 scopus 로고
    • Revision ligament reconstruction of failed prosthetic anterior cruciate ligaments
    • Steadman J.R., Seeman M.D., and Hutton K.S. Revision ligament reconstruction of failed prosthetic anterior cruciate ligaments. Instr Course Lect 44 (1995) 417
    • (1995) Instr Course Lect , vol.44 , pp. 417
    • Steadman, J.R.1    Seeman, M.D.2    Hutton, K.S.3
  • 22
    • 0026528430 scopus 로고
    • Inflammatory response to subcutaneously implanted Marlex and Gore-Tex in massively obese patients
    • Stockeld D., Granstrom L., Backman L., et al. Inflammatory response to subcutaneously implanted Marlex and Gore-Tex in massively obese patients. Biomaterials 13 (1992) 261
    • (1992) Biomaterials , vol.13 , pp. 261
    • Stockeld, D.1    Granstrom, L.2    Backman, L.3
  • 23
    • 0031908492 scopus 로고    scopus 로고
    • Lymphadenopathy after Gore-Tex anterior cruciate ligament reconstruction
    • Wilson A.G., Plessas S.J., Gray T., et al. Lymphadenopathy after Gore-Tex anterior cruciate ligament reconstruction. Am J Sports Med 26 (1998) 133
    • (1998) Am J Sports Med , vol.26 , pp. 133
    • Wilson, A.G.1    Plessas, S.J.2    Gray, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.