메뉴 건너뛰기




Volumn 32, Issue 3, 2006, Pages 153-156

Location and removal of non-palpable Implanon® implants with the aid of ultrasound guidance

Author keywords

[No Author keywords available]

Indexed keywords

ETONOGESTREL;

EID: 33746278144     PISSN: 14711893     EISSN: None     Source Type: Journal    
DOI: 10.1783/147118906777888549     Document Type: Article
Times cited : (31)

References (12)
  • 1
    • 0032611008 scopus 로고    scopus 로고
    • Implanon. A review of clinical studies
    • Edwards JE, Moore A. Implanon. A review of clinical studies. Br J Fam Plann 1999; 24(4 Suppl.): 3-16.
    • (1999) Br J Fam Plann , vol.24 , Issue.4 SUPPL. , pp. 3-16
    • Edwards, J.E.1    Moore, A.2
  • 2
    • 0029149229 scopus 로고
    • Removal of levonorgestrel capsules from the biceps muscle
    • Creinin MD, Klaisle CM. Removal of levonorgestrel capsules from the biceps muscle. Int J Gynaecol Obstet 1995; 50: 189-191.
    • (1995) Int J Gynaecol Obstet , vol.50 , pp. 189-191
    • Creinin, M.D.1    Klaisle, C.M.2
  • 3
    • 0028951188 scopus 로고
    • Localization of "lost" Norplant capsules using compression film screen mammography
    • Letterie GS, Garnaas M. Localization of "lost" Norplant capsules using compression film screen mammography. Obstet Gynecol 1995; 85: 886-887.
    • (1995) Obstet Gynecol , vol.85 , pp. 886-887
    • Letterie, G.S.1    Garnaas, M.2
  • 4
    • 0031799856 scopus 로고    scopus 로고
    • Real-time ultrasonographically guided removal of nonpalpable and intramuscular Norplant capsules
    • Nelson AL, Sinow RM. Real-time ultrasonographically guided removal of nonpalpable and intramuscular Norplant capsules. Am J Obstet Gynecol 1998; 178: 1185-1193.
    • (1998) Am J Obstet Gynecol , vol.178 , pp. 1185-1193
    • Nelson, A.L.1    Sinow, R.M.2
  • 6
    • 0034796854 scopus 로고    scopus 로고
    • Non-palpable ultrasonographically not detectable Implanon rods can be localized by magnetic resonance imaging
    • Merki-Feld GS, Brekenfeld C, Migge B, Keller PJ. Non-palpable ultrasonographically not detectable Implanon rods can be localized by magnetic resonance imaging. Contraception 2001; 63: 325-328.
    • (2001) Contraception , vol.63 , pp. 325-328
    • Merki-Feld, G.S.1    Brekenfeld, C.2    Migge, B.3    Keller, P.J.4
  • 7
    • 0142155543 scopus 로고    scopus 로고
    • Implanon implant detection with ultrasound and magnetic resonance imaging
    • Westerway SC, Picker R, Christie J. Implanon implant detection with ultrasound and magnetic resonance imaging. Aust N Z J Obstet Gynecol 2003; 43: 346-350.
    • (2003) Aust N Z J Obstet Gynecol , vol.43 , pp. 346-350
    • Westerway, S.C.1    Picker, R.2    Christie, J.3
  • 8
    • 0031438020 scopus 로고    scopus 로고
    • Ultrasound characteristics of subdermally implanted Implanon contraceptive rods
    • Lantz A. Nosher JL, Pasquale S, Siegel RL. Ultrasound characteristics of subdermally implanted Implanon contraceptive rods. Contraception 1997; 56: 323-327.
    • (1997) Contraception , vol.56 , pp. 323-327
    • Lantz, A.1    Nosher, J.L.2    Pasquale, S.3    Siegel, R.L.4
  • 9
    • 15744396784 scopus 로고    scopus 로고
    • Unintended pregnancies with etonogestrel implant (Implanon): A case series from postmarketing experience in Australia
    • Harrison-Woolrych M, Hill R. Unintended pregnancies with etonogestrel implant (Implanon): a case series from postmarketing experience in Australia. Contraception 2005; 71: 306-308.
    • (2005) Contraception , vol.71 , pp. 306-308
    • Harrison-Woolrych, M.1    Hill, R.2
  • 11
    • 0030222151 scopus 로고    scopus 로고
    • Modified needle elevation technique for misplaced Norplant implants removal
    • Taneepanichskul S, Intaraprasert S, Chaturachinda K. Modified needle elevation technique for misplaced Norplant implants removal. Contraception 1996; 54: 87-89.
    • (1996) Contraception , vol.54 , pp. 87-89
    • Taneepanichskul, S.1    Intaraprasert, S.2    Chaturachinda, K.3
  • 12
    • 33746318874 scopus 로고    scopus 로고
    • Removal techniques for deep sub-dermal, sub-facial and intramuscular Implanon contraceptive implants: Experience of a Fertility Control Unit
    • Gbolade BA, Weston MJ. Removal techniques for deep sub-dermal, sub-facial and intramuscular Implanon contraceptive implants: experience of a Fertility Control Unit. Eur J Contracept Reprod Health Care 2004; 9(Suppl. 1): 30.
    • (2004) Eur J Contracept Reprod Health Care , vol.9 , Issue.SUPPL. 1 , pp. 30
    • Gbolade, B.A.1    Weston, M.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.