메뉴 건너뛰기




Volumn 153, Issue 4, 2006, Pages 493-498

Increasing wind farm capacity

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC FAULT CURRENTS; ELECTRIC NETWORK ANALYSIS; ELECTRIC POTENTIAL; ELECTRIC RESISTANCE; WIND TURBINES;

EID: 33746210078     PISSN: 13502360     EISSN: None     Source Type: Journal    
DOI: 10.1049/ip-gtd:20050279     Document Type: Article
Times cited : (18)

References (17)
  • 1
    • 0036494483 scopus 로고    scopus 로고
    • Flicker emission of wind turbines during continuous operation
    • 10.1109/60.986447 0885-8969
    • Larsson, A.: ' Flicker emission of wind turbines during continuous operation ', IEEE Trans. Energy Convers., 2002, 17, p. 114-118 10.1109/60.986447 0885-8969
    • (2002) IEEE Trans. Energy Convers. , vol.17 , pp. 114-118
    • Larsson, A.1
  • 2
    • 0036494323 scopus 로고    scopus 로고
    • Flicker emission of wind turbines caused by switching operations
    • 10.1109/60.986448 0885-8969
    • Larsson, A.: ' Flicker emission of wind turbines caused by switching operations ', IEEE Trans. Energy Convers., 2002, 17, p. 119-123 10.1109/60.986448 0885-8969
    • (2002) IEEE Trans. Energy Convers. , vol.17 , pp. 119-123
    • Larsson, A.1
  • 4
    • 0034108775 scopus 로고    scopus 로고
    • Exploitation of wind-energy resources in proximity to weak electric grids
    • 10.1016/S0306-2619(99)00098-7 0306-2619
    • Tande, J.O.V.: ' Exploitation of wind-energy resources in proximity to weak electric grids ', Appl. Energy., 2000, 65, p. 395-401 10.1016/S0306- 2619(99)00098-7 0306-2619
    • (2000) Appl. Energy. , vol.65 , pp. 395-401
    • Tande, J.O.V.1
  • 5
    • 0038306709 scopus 로고    scopus 로고
    • Direct control of residential water heater loads to reduce power system distribution losses
    • Columbus, OH
    • Salehfar, H., and Wehte, A.: ' Direct control of residential water heater loads to reduce power system distribution losses ', Presented at the IEEE PES 2001 Winter Power Meeting, Columbus, OH, 2001
    • (2001) Presented at the IEEE PES 2001 Winter Power Meeting
    • Salehfar, H.1    Wehte, A.2
  • 6
    • 14344257208 scopus 로고    scopus 로고
    • Applying power quality characteristics of wind turbines for assessing impact on voltage quality
    • Tande, J.O.V.: ' Applying power quality characteristics of wind turbines for assessing impact on voltage quality ', Wind Energy, 2002, 5, p. 37-52
    • (2002) Wind Energy , vol.5 , pp. 37-52
    • Tande, J.O.V.1
  • 8
    • 4544388007 scopus 로고    scopus 로고
    • Co-ordinated voltage control strategy for a doubly-fed induction generator based wind farm
    • 10.1049/ip-gtd:20040581 1350-2360
    • Cartwright, P., Holdsworth, L., Ekanayake, J. B., and Jenkins, N.: ' Co-ordinated voltage control strategy for a doubly-fed induction generator based wind farm ', IEE Proc., Gener. Transm. Distrib., 2004, 151, (4), p. 495-502 10.1049/ip-gtd:20040581 1350-2360
    • (2004) IEE Proc., Gener. Transm. Distrib. , vol.151 , Issue.4 , pp. 495-502
    • Cartwright, P.1    Holdsworth, L.2    Ekanayake, J.B.3    Jenkins, N.4
  • 9
    • 0035555017 scopus 로고    scopus 로고
    • Voltage control methods with grid connected wind turbines
    • 10.1260/030952401760217157 0309-524X
    • Slootweg, J.G., de Haan, S.W.H., Polinder, H., and Kling, W.L.: ' Voltage control methods with grid connected wind turbines ', Wind Eng., 2001, 25, p. 353-366 10.1260/030952401760217157 0309-524X
    • (2001) Wind Eng. , vol.25 , pp. 353-366
    • Slootweg, J.G.1    De Haan, S.W.H.2    Polinder, H.3    Kling, W.L.4
  • 11
    • 0036465326 scopus 로고    scopus 로고
    • Voltage rise: The big issue when connecting embedded generation to long 11 kV overhead lines
    • Masters, C.: ' Voltage rise: the big issue when connecting embedded generation to long 11 kV overhead lines ', IEE Power Eng. J., 2002, 16, (1), p. 5-12
    • (2002) IEE Power Eng. J. , vol.16 , Issue.1 , pp. 5-12
    • Masters, C.1
  • 15
    • 0032690957 scopus 로고    scopus 로고
    • Impact of embedded generation on emergency reserve
    • 10.1049/ip-gtd:19990070 1350-2360
    • O'Kane, P.J., Fox, B., and Morrow, D.J.: ' Impact of embedded generation on emergency reserve ', IEE Proc., Gener. Transm. Distrib., 1999, 146, (2), p. 159-163 10.1049/ip-gtd:19990070 1350-2360
    • (1999) IEE Proc., Gener. Transm. Distrib. , vol.146 , Issue.2 , pp. 159-163
    • O'Kane, P.J.1    Fox, B.2    Morrow, D.J.3
  • 16
    • 0030146394 scopus 로고    scopus 로고
    • Doubly-fed induction generator using back-to-back PWM converters and its application to variable speed wind-energy generation
    • 10.1049/ip-epa:19960288 1350-2352
    • Pena, R., Clare, J.C., and Asher, G.: ' Doubly-fed induction generator using back-to-back PWM converters and its application to variable speed wind-energy generation ', IEE Proc., Electr. Power Appl., 1996, 143, (3), p. 231-241 10.1049/ip-epa:19960288 1350-2352
    • (1996) IEE Proc., Electr. Power Appl. , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.3
  • 17
    • 0036575603 scopus 로고    scopus 로고
    • Doubly-fed induction generator systems for wind turbines
    • 1077-2618
    • Muller, S., Deicke, M., and De Doncker, R.W.: ' Doubly-fed induction generator systems for wind turbines ', IEEE Ind. Appl. Mag., 2002, p. 26-33 1077-2618
    • (2002) IEEE Ind. Appl. Mag. , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.