메뉴 건너뛰기




Volumn 43, Issue 2, 2006, Pages 273-285

Selection of an optimal muscle set for a 16-channel standing neuroprosthesis using a human musculoskeletal model

Author keywords

Bipedal balance; Functional electrical stimulation; Lower limb musculature; Muscle selection; Musculoskeletal model; Neuroprostheses; Posture shifting; Rehabilitation engineering; Spinal cord injury; Standing balance; Unassisted standing

Indexed keywords

GASTROENTEROLOGY; METABOLISM; NEUROLOGY; POLYNOMIALS; PROSTHETICS; THREE DIMENSIONAL;

EID: 33746191761     PISSN: 07487711     EISSN: 07487711     Source Type: Journal    
DOI: 10.1682/JRRD.2005.04.0072     Document Type: Article
Times cited : (15)

References (27)
  • 2
    • 0027359079 scopus 로고
    • Predictors of assistive technology abandonment
    • Phillips B, Zhao H. Predictors of assistive technology abandonment. Assist Technol. 1993;5(1):36-45.
    • (1993) Assist Technol , vol.5 , Issue.1 , pp. 36-45
    • Phillips, B.1    Zhao, H.2
  • 3
    • 0018360801 scopus 로고
    • Electrical splinting of the knee in paraplegia
    • Brindley GS, Polkey CE, Rushton DN. Electrical splinting of the knee in paraplegia. Paraplegia. 1979;16(4):428-37.
    • (1979) Paraplegia , vol.16 , Issue.4 , pp. 428-437
    • Brindley, G.S.1    Polkey, C.E.2    Rushton, D.N.3
  • 4
    • 0019436431 scopus 로고
    • Use of a two-channel functional electrical stimulator to stand paraplegic patients
    • Bajd T, Kralj A, Sega J, Turk R, Benko H, Strojnik P. Use of a two-channel functional electrical stimulator to stand paraplegic patients. Phys Ther. 1981;61(4):526-27.
    • (1981) Phys Ther , vol.61 , Issue.4 , pp. 526-527
    • Bajd, T.1    Kralj, A.2    Sega, J.3    Turk, R.4    Benko, H.5    Strojnik, P.6
  • 5
    • 0022912415 scopus 로고
    • Posture switching for prolonging functional electrical stimulation standing in paraplegic patients
    • Krajl A, Bajd T, Turk R, Benko H. Posture switching for prolonging functional electrical stimulation standing in paraplegic patients. Paraplegia. 1986;24(4):221-30.
    • (1986) Paraplegia , vol.24 , Issue.4 , pp. 221-230
    • Krajl, A.1    Bajd, T.2    Turk, R.3    Benko, H.4
  • 6
    • 0029911085 scopus 로고    scopus 로고
    • Implanted Functional Neuromuscular Stimulation systems for individuals with cervical spinal cord injuries: Clinical case reports
    • Triolo RJ, Bieri C, Uhlir JP, Kobetic R, Scheiner A, Marsolais EB. Implanted Functional Neuromuscular Stimulation systems for individuals with cervical spinal cord injuries: clinical case reports. Arch Phys Med Rehabil. 1996;77(11):1119-28.
    • (1996) Arch Phys Med Rehabil , vol.77 , Issue.11 , pp. 1119-1128
    • Triolo, R.J.1    Bieri, C.2    Uhlir, J.P.3    Kobetic, R.4    Scheiner, A.5    Marsolais, E.B.6
  • 8
    • 0035708730 scopus 로고    scopus 로고
    • Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers - Where do we stand?
    • Davis JA Jr, Triolo RJ, Uhlir JP, Bieri C, Rohde L, Lissy DA, Kukke S. Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers - where do we stand? J Rehabil Res Dev. 2001;38(6):609-17.
    • (2001) J Rehabil Res Dev , vol.38 , Issue.6 , pp. 609-617
    • Davis Jr., J.A.1    Triolo, R.J.2    Uhlir, J.P.3    Bieri, C.4    Rohde, L.5    Lissy, D.A.6    Kukke, S.7
  • 9
    • 28144447489 scopus 로고    scopus 로고
    • Effects of functional electrical stimulation on the joints of adolescents with spinal cord injury
    • Betz R, Boden B, Triolo RJ, Mesgarzadeh M, Gardner E, Fife R. Effects of functional electrical stimulation on the joints of adolescents with spinal cord injury. Paraplegia. 1996;34(3):127-36.
    • (1996) Paraplegia , vol.34 , Issue.3 , pp. 127-136
    • Betz, R.1    Boden, B.2    Triolo, R.J.3    Mesgarzadeh, M.4    Gardner, E.5    Fife, R.6
  • 10
    • 0346880311 scopus 로고    scopus 로고
    • Effects of regular use of neuromuscular electrical stimulation on tissue health
    • Bogie KM, Triolo RJ. Effects of regular use of neuromuscular electrical stimulation on tissue health. J Rehabil Res Dev. 2003;40(6):469-75.
    • (2003) J Rehabil Res Dev , vol.40 , Issue.6 , pp. 469-475
    • Bogie, K.M.1    Triolo, R.J.2
  • 11
    • 0035184197 scopus 로고    scopus 로고
    • Control of paraplegic ankle joint stiffness using FES while standing
    • Hunt KJ, Gollee H, Jaime RP. Control of paraplegic ankle joint stiffness using FES while standing. Med Eng Phys. 2001;23(8):541-55.
    • (2001) Med Eng Phys , vol.23 , Issue.8 , pp. 541-555
    • Hunt, K.J.1    Gollee, H.2    Jaime, R.P.3
  • 12
    • 0242664835 scopus 로고    scopus 로고
    • A computational technique for determining the ground reaction forces in human bipedal stance
    • Audu ML, Kirsch RF, Triolo RJ. A computational technique for determining the ground reaction forces in human bipedal stance. J Appl Biomech. 2003;19(4):361-71.
    • (2003) J Appl Biomech , vol.19 , Issue.4 , pp. 361-371
    • Audu, M.L.1    Kirsch, R.F.2    Triolo, R.J.3
  • 13
    • 0022749698 scopus 로고
    • Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities
    • Marsolais EB, Kobetic R. Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities. J Rehabil Res Dev. 1986;23(3):1-8.
    • (1986) J Rehabil Res Dev , vol.23 , Issue.3 , pp. 1-8
    • Marsolais, E.B.1    Kobetic, R.2
  • 14
    • 0024326709 scopus 로고
    • Muscle and tendon: Properties, models, scaling, and application to biomechanics and motor control
    • Zajac FE. Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. Crit Rev Biomed Eng. 1989;17(4):359-411.
    • (1989) Crit Rev Biomed Eng , vol.17 , Issue.4 , pp. 359-411
    • Zajac, F.E.1
  • 15
    • 0022487364 scopus 로고
    • The sensitivity of muscle force predictions to changes in physiologic cross-sectional area
    • Brand RA, Pedersen DR, Friederich JA. The sensitivity of muscle force predictions to changes in physiologic cross-sectional area. J Biomech. 1986;19(8):589-96.
    • (1986) J Biomech , vol.19 , Issue.8 , pp. 589-596
    • Brand, R.A.1    Pedersen, D.R.2    Friederich, J.A.3
  • 17
    • 0025238930 scopus 로고
    • Muscle fiber architecture in the human lower limb
    • Friederich JA, Brand RA. Muscle fiber architecture in the human lower limb. J Biomech. 1990;23(1):91-95.
    • (1990) J Biomech , vol.23 , Issue.1 , pp. 91-95
    • Friederich, J.A.1    Brand, R.A.2
  • 18
    • 0035708669 scopus 로고    scopus 로고
    • Selectivity of intramuscular stimulating electrodes in the lower limbs
    • Triolo RJ, Liu MQ, Kobetic R, Uhlir JP. Selectivity of intramuscular stimulating electrodes in the lower limbs. J Rehabil Res Dev. 2001;38(5):533-44.
    • (2001) J Rehabil Res Dev , vol.38 , Issue.5 , pp. 533-544
    • Triolo, R.J.1    Liu, M.Q.2    Kobetic, R.3    Uhlir, J.P.4
  • 19
    • 0034470609 scopus 로고    scopus 로고
    • The use of selective electrical stimulation of the quadriceps to improve standing function in paraplegia
    • Uhlir JP, Triolo RJ, Kobetic R. The use of selective electrical stimulation of the quadriceps to improve standing function in paraplegia. IEEE Trans Rehabil Eng. 2000;8(4):514-22.
    • (2000) IEEE Trans Rehabil Eng , vol.8 , Issue.4 , pp. 514-522
    • Uhlir, J.P.1    Triolo, R.J.2    Kobetic, R.3
  • 20
    • 0023223730 scopus 로고
    • Functional electrical stimulation for walking in paraplegia
    • Marsolais EB, Kobetic R. Functional electrical stimulation for walking in paraplegia. J Bone Joint Surg Am. 1987;69(5):728-33.
    • (1987) J Bone Joint Surg Am , vol.69 , Issue.5 , pp. 728-733
    • Marsolais, E.B.1    Kobetic, R.2
  • 21
    • 0022361685 scopus 로고
    • Quantification of lumbar function. Part 1: Isometric and multispeed isokinetic trunk strength measures in sagittal and axial planes in normal subjects
    • Smith SS, Mayer TG, Gatchel RJ, Becker TJ. Quantification of lumbar function. Part 1: Isometric and multispeed isokinetic trunk strength measures in sagittal and axial planes in normal subjects. Spine. 1985;10(8):757-64.
    • (1985) Spine , vol.10 , Issue.8 , pp. 757-764
    • Smith, S.S.1    Mayer, T.G.2    Gatchel, R.J.3    Becker, T.J.4
  • 22
    • 1542314276 scopus 로고    scopus 로고
    • Effects of spinal cord injury on lower-limb passive joint moments revealed through a nonlinear viscoelastic model
    • Amankwah K, Triolo RJ, Kirsch RF. Effects of spinal cord injury on lower-limb passive joint moments revealed through a nonlinear viscoelastic model. J Rehabil Res Dev. 2004;41(1):15-32.
    • (2004) J Rehabil Res Dev , vol.41 , Issue.1 , pp. 15-32
    • Amankwah, K.1    Triolo, R.J.2    Kirsch, R.F.3
  • 23
    • 0019784508 scopus 로고
    • A physiologically based criterion of muscle force prediction in locomotion
    • Crowninshield RD, Brand RA. A physiologically based criterion of muscle force prediction in locomotion. J Biomech. 1981;14(11):793-801.
    • (1981) J Biomech , vol.14 , Issue.11 , pp. 793-801
    • Crowninshield, R.D.1    Brand, R.A.2
  • 24
    • 0031149651 scopus 로고    scopus 로고
    • Functional stability limits while holding loads in various positions
    • Holbein MA, Redfern MS. Functional stability limits while holding loads in various positions. Int J Ind Ergon. 1997;19(5):387-95.
    • (1997) Int J Ind Ergon , vol.19 , Issue.5 , pp. 387-395
    • Holbein, M.A.1    Redfern, M.S.2
  • 26
    • 0031105362 scopus 로고    scopus 로고
    • Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia
    • Kobetic R, Triolo RJ, Marsolais EB. Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia. IEEE Trans Rehabil Eng. 1997;5(1):23-29.
    • (1997) IEEE Trans Rehabil Eng , vol.5 , Issue.1 , pp. 23-29
    • Kobetic, R.1    Triolo, R.J.2    Marsolais, E.B.3
  • 27
    • 0022548774 scopus 로고
    • Central programming of postural movements: Adaptation to altered support-surface configurations
    • Horak FB, Nashner LM. Central programming of postural movements: adaptation to altered support-surface configurations. J Neurophysiol. 1986;55(6):1369-81.
    • (1986) J Neurophysiol , vol.55 , Issue.6 , pp. 1369-1381
    • Horak, F.B.1    Nashner, L.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.