-
1
-
-
0033286354
-
Computer-assisted planning and simulation of hip operations using virtual three-dimensional models
-
H Handels, J Ehrhardt, W Plotz, S Poppl, "Computer-Assisted Planning and Simulation of Hip Operations Using Virtual Three-Dimensional Models", Studies in Health Technol Inform, Vol 68, pp 686-689, 1999
-
(1999)
Studies in Health Technol Inform
, vol.68
, pp. 686-689
-
-
Handels, H.1
Ehrhardt, J.2
Plotz, W.3
Poppl, S.4
-
2
-
-
0038120878
-
Comparison of the fit and fill between the anatomic hip femoral component and the verSys taper femoral component using virtual implantation
-
S Nishihara, N Sugano, T Nishii, H Tanaka, H Yoshikawa, and A Ochi, "Comparison of the Fit and Fill between the Anatomic Hip Femoral Component and the VerSys Taper Femoral Component using Virtual Implantation", J Orthop Sci, Vol 8(3), pp 352-360, 2003
-
(2003)
J Orthop Sci
, vol.8
, Issue.3
, pp. 352-360
-
-
Nishihara, S.1
Sugano, N.2
Nishii, T.3
Tanaka, H.4
Yoshikawa, H.5
Ochi, A.6
-
3
-
-
0031690023
-
Computer assisted measurement of cup placement in total hip replacement
-
B Jaramaz, A M DiGioia, M Blackwell, and C Nikou, "Computer Assisted Measurement of Cup Placement in Total Hip Replacement", Clin Orthop, Vol 354, pp 70-81, 1998
-
(1998)
Clin Orthop
, vol.354
, pp. 70-81
-
-
Jaramaz, B.1
DiGioia, A.M.2
Blackwell, M.3
Nikou, C.4
-
4
-
-
0036523483
-
Effect of the display modality on the spatial accuracy of orthopaedic surgery pre-operative planning applications
-
M Viceconti, R Lattanzi, C Zannoni, and A Cappello, "Effect of the display modality on the spatial accuracy of orthopaedic surgery pre-operative planning applications", Medical Informatics and the Internet in Medicine, Vol 27(1), pp 21-32, 2002
-
(2002)
Medical Informatics and the Internet in Medicine
, vol.27
, Issue.1
, pp. 21-32
-
-
Viceconti, M.1
Lattanzi, R.2
Zannoni, C.3
Cappello, A.4
-
5
-
-
0037410361
-
CT-based surgical planning software improves the accuracy of THR preoperative planning
-
M Viceconti, R Lattanzi, B Antonietti, S Paderni, R Olmi, A Sudanese, and A Toni, "CT-based Surgical Planning Software Improves the Accuracy of THR Preoperative Planning", Medical Engineering & Physics, Vol 25(5), pp 371-377, 2003
-
(2003)
Medical Engineering & Physics
, vol.25
, Issue.5
, pp. 371-377
-
-
Viceconti, M.1
Lattanzi, R.2
Antonietti, B.3
Paderni, S.4
Olmi, R.5
Sudanese, A.6
Toni, A.7
-
6
-
-
33746129944
-
-
http://sirio.cineca.it/B3C/multisense
-
-
-
-
7
-
-
33746165120
-
-
http://sirio.cineca.it/B3C/MAF
-
-
-
-
8
-
-
4644323850
-
The multimod application framework
-
IEEE Comp. Soc. Press
-
M Viceconti, A Leardini, C Zannoni, D Testi, F Taddei, L Astolfi, M Petrone, S Imboden and P Quadrani, "The Multimod Application Framework", Proc Information Visualisation 04, IEEE Comp. Soc. Press, pp 15-20, 2004
-
(2004)
Proc Information Visualisation 04
, pp. 15-20
-
-
Viceconti, M.1
Leardini, A.2
Zannoni, C.3
Testi, D.4
Taddei, F.5
Astolfi, L.6
Petrone, M.7
Imboden, S.8
Quadrani, P.9
-
9
-
-
33746163858
-
-
http://www.vtk.org
-
-
-
-
10
-
-
33746131586
-
A multimodal and multisensorial pre-operative planning environment for total hip replacement
-
D Testi, C Zannoni, M Petrone, G J Clapworthy, D Nieberg, N O Tsagarakis, D O Caldwell, M Viceconti, "A Multimodal and Multisensorial Pre-Operative Planning Environment for Total Hip Replacement", Proc MediViz 05, 2005
-
(2005)
Proc MediViz 05
-
-
Testi, D.1
Zannoni, C.2
Petrone, M.3
Clapworthy, G.J.4
Nieberg, D.5
Tsagarakis, N.O.6
Caldwell, D.O.7
Viceconti, M.8
-
11
-
-
0034108782
-
Complications of total hip arthroplasty: MR imaging - Initial experience
-
L White, J Kim, M Mehta, N Merchant, M Schweitzer, W Morrison, C Hutchinson and A Gross, "Complications of Total Hip Arthroplasty: MR Imaging - Initial Experience", Radiology, Vol 215(1), pp 254-262, 2000
-
(2000)
Radiology
, vol.215
, Issue.1
, pp. 254-262
-
-
White, L.1
Kim, J.2
Mehta, M.3
Merchant, N.4
Schweitzer, M.5
Morrison, W.6
Hutchinson, C.7
Gross, A.8
-
12
-
-
33746128389
-
-
http://www.bartsandthelondon.org.uk/docs/ARsection_4.pdf
-
-
-
-
13
-
-
0023381475
-
Marching cubes: A high resolution 3D surface construction algorithm
-
W Lorensen and H Cline, "Marching Cubes: a High Resolution 3D Surface Construction Algorithm", Computer Graphics, 21(4), pp 163-169, 1987
-
(1987)
Computer Graphics
, vol.21
, Issue.4
, pp. 163-169
-
-
Lorensen, W.1
Cline, H.2
-
14
-
-
33746150359
-
-
http://www.nlm.nih.gov/research/visible_human.html
-
-
-
-
15
-
-
0032298837
-
Globally constrained deformable models for 3D object reconstruction
-
J Montagnat and H Delingette, "Globally Constrained Deformable Models for 3D Object Reconstruction", Signal Processing, Vol 71(2), pp 173-186, 1998
-
(1998)
Signal Processing
, vol.71
, Issue.2
, pp. 173-186
-
-
Montagnat, J.1
Delingette, H.2
-
16
-
-
0034070906
-
The mesh-matching algorithm: An automatic 3D mesh generator for finite element structures
-
B Couteau, Y Payan and S Lavallee, "The Mesh-Matching Algorithm: An Automatic 3D Mesh Generator for Finite Element Structures", Journal of Biomechanics, Vol 33, pp 1005-1009, 2000
-
(2000)
Journal of Biomechanics
, vol.33
, pp. 1005-1009
-
-
Couteau, B.1
Payan, Y.2
Lavallee, S.3
-
17
-
-
84958165400
-
Constructing patient specific models for correcting intraoperative brain deformation
-
Lecture Notes in Comp. Sci.
-
A Castellano-Smith, T Hartkens, J Scnabel, D Hose, H Liu, W Hall, C Truwit, D Hawkes and D Hill, "Constructing Patient Specific Models for Correcting Intraoperative Brain Deformation", Proc Medical Image Computing and. Computer-Assisted Intervention, Vol 2208 (Lecture Notes in Comp. Sci.), pp 1091-1098, 2001
-
(2001)
Proc Medical Image Computing And. Computer-assisted Intervention
, vol.2208
, pp. 1091-1098
-
-
Castellano-Smith, A.1
Hartkens, T.2
Scnabel, J.3
Hose, D.4
Liu, H.5
Hall, W.6
Truwit, C.7
Hawkes, D.8
Hill, D.9
|