메뉴 건너뛰기




Volumn 25, Issue 4, 2006, Pages 671-680

Measurements of gastric emptying during continuous nasogastric infusion of liquid feed: Electric impedance tomography versus gamma scintigraphy

Author keywords

Continuous nasogastric infusion; Electric impedance tomography (EIT); Enteral feed; Gamma scintigraphy; Gastric residual volume (GRV)

Indexed keywords

IBUPROFEN; MOMETASONE FUROATE;

EID: 33746089550     PISSN: 02615614     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clnu.2005.11.015     Document Type: Article
Times cited : (40)

References (14)
  • 1
    • 0026573994 scopus 로고
    • Use of residual volume as a marker for enteral feeding intolerance: prospective blinded comparison with physical examination and radiographic findings
    • McClave S.A., et al. Use of residual volume as a marker for enteral feeding intolerance: prospective blinded comparison with physical examination and radiographic findings. J Parenter Enteral Nutr 16 2 (1992) 99-105
    • (1992) J Parenter Enteral Nutr , vol.16 , Issue.2 , pp. 99-105
    • McClave, S.A.1
  • 2
    • 17544397679 scopus 로고    scopus 로고
    • Clinical use of gastric residual volumes as a monitor for patients on enteral tube feeding
    • McClave S.A., and Snider H.L. Clinical use of gastric residual volumes as a monitor for patients on enteral tube feeding. J Parenter Enteral Nutr 26 6 Suppl (2002) S43-S48
    • (2002) J Parenter Enteral Nutr , vol.26 , Issue.6 SUPPL
    • McClave, S.A.1    Snider, H.L.2
  • 3
    • 0345093281 scopus 로고    scopus 로고
    • The limitations of using gastric residual volumes to monitor enteral feedings: a mathematical model
    • Burd R.S., and Lentz C.W. The limitations of using gastric residual volumes to monitor enteral feedings: a mathematical model. Nutr Clin Practice 16 6 (2001) 349-356
    • (2001) Nutr Clin Practice , vol.16 , Issue.6 , pp. 349-356
    • Burd, R.S.1    Lentz, C.W.2
  • 4
    • 0030967440 scopus 로고    scopus 로고
    • Stopping enteral feeding for arbitrary gastric residual volume may not be physiologically sound: results of a computer simulation model
    • Lin H.C., and Van Citters G.W. Stopping enteral feeding for arbitrary gastric residual volume may not be physiologically sound: results of a computer simulation model. J Parenter Enteral Nutr 21 5 (1997) 286-289
    • (1997) J Parenter Enteral Nutr , vol.21 , Issue.5 , pp. 286-289
    • Lin, H.C.1    Van Citters, G.W.2
  • 5
    • 0023139618 scopus 로고
    • Applied potential tomography. A new noninvasive technique for measuring gastric emptying
    • Avill R., et al. Applied potential tomography. A new noninvasive technique for measuring gastric emptying. Gastroenterology 92 4 (1987) 1019-1026
    • (1987) Gastroenterology , vol.92 , Issue.4 , pp. 1019-1026
    • Avill, R.1
  • 6
    • 0025718859 scopus 로고
    • Applied potential tomography. Noninvasive method for measuring gastric emptying of a solid test meal
    • Mangnall Y.F., et al. Applied potential tomography. Noninvasive method for measuring gastric emptying of a solid test meal. Dig Dis Sci 36 12 (1991) 1680-1684
    • (1991) Dig Dis Sci , vol.36 , Issue.12 , pp. 1680-1684
    • Mangnall, Y.F.1
  • 8
    • 0028596990 scopus 로고
    • Gastric motility and emptying studies with radionuclides in research and clinical settings
    • Akkermans L.M., and van Isselt J.W. Gastric motility and emptying studies with radionuclides in research and clinical settings. Dig Dis Sci 39 12 Suppl (1994) 95S-96S
    • (1994) Dig Dis Sci , vol.39 , Issue.12 SUPPL
    • Akkermans, L.M.1    van Isselt, J.W.2
  • 9
    • 0028605874 scopus 로고
    • Methods to study gastric emptying
    • Vantrappen G. Methods to study gastric emptying. Dig Dis Sci 39 12 Suppl (1994) 91S-94S
    • (1994) Dig Dis Sci , vol.39 , Issue.12 SUPPL
    • Vantrappen, G.1
  • 10
    • 33746093393 scopus 로고    scopus 로고
    • Gabriel C, Gabriel S. Compilation of the dielectric properties of body tissues at RF and microwave frequencies. 〈www.brooks.af.mil/AFRL/HED/hedr/reports/dielectric/home.html〉.
  • 11
    • 33746083339 scopus 로고    scopus 로고
    • Stata Corporation, Stata PC, Texas
    • Stata Corporation. Stata 8 (2003), Stata PC, Texas
    • (2003) Stata 8
  • 12
    • 0037350724 scopus 로고    scopus 로고
    • Labeled acetate to assess intestinal absorption in critically ill patients
    • Chiolero R.L., et al. Labeled acetate to assess intestinal absorption in critically ill patients. Crit Care Med 31 3 (2003) 853-857
    • (2003) Crit Care Med , vol.31 , Issue.3 , pp. 853-857
    • Chiolero, R.L.1
  • 13
    • 33746072031 scopus 로고    scopus 로고
    • Soulsby C, Yazaki E, Evans DF, Powell-Tuck J. Can electrical impedance tomographic spectroscopy (EITS) be used to measure enteral feed tolerance? Clin Nutr 2002;21:48.
  • 14
    • 0028847501 scopus 로고
    • Applied potential tomography in the measurement of gastric emptying in infants
    • Nour S., et al. Applied potential tomography in the measurement of gastric emptying in infants. J Paediatr Gastroenterol Nutr 20 1 (1995) 65-72
    • (1995) J Paediatr Gastroenterol Nutr , vol.20 , Issue.1 , pp. 65-72
    • Nour, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.