Health failure mode and effect analysis for clinical engineering: Application on cardiac defibrillators

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOMEDICAL ENGINEERING; BRAZIL; DEFIBRILLATION; DEFIBRILLATOR; HAZARD ASSESSMENT; HEALTH CARE QUALITY; MEDICAL INSTRUMENTATION; PUBLIC HOSPITAL; SAFETY;

EID: 33745905020     PISSN: 03638855     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004669-200604000-00028     Document Type: Article
Times cited : (7)

References (10)
  • 3
    • 0036597112 scopus 로고    scopus 로고
    • Emergency Care Research Institute (ECRI) An introduction to FMEA, using failure mode effects analysis to meet JCAHO's proactive risk assessment requirement
    • Emergency Care Research Institute (ECRI) An introduction to FMEA, using failure mode effects analysis to meet JCAHO's proactive risk assessment requirement. Health Devices. 2002;31:223-226.
    • (2002) Health Devices , vol.31 , pp. 223-226
  • 4
    • 33744459293 scopus 로고    scopus 로고
    • Emergency Care Research Institute (ECRI) Hospitals tackle new JCAHO requirement with failure mode and effects analysis
    • Emergency Care Research Institute (ECRI) Hospitals tackle new JCAHO requirement with failure mode and effects analysis. Risk Manag Report. 2002;21:1-7.
    • (2002) Risk Manag Report , vol.21 , pp. 1-7
  • 5
    • 17144458594 scopus 로고    scopus 로고
    • JCAHO: Meeting the standards for patient safety, a focus on medication safety is required under Joint Commission tandards, and tools are available to help pharmacists achieve the best possible outcomes
    • Grissinger M, Rich D. JCAHO: Meeting the standards for patient safety, a focus on medication safety is required under Joint Commission tandards, and tools are available to help pharmacists achieve the best possible outcomes. J Am Pharm Assoc. 2002;42(Suppl 1): S54-S55.
    • (2002) J Am Pharm Assoc , vol.42 , Issue.1 SUPPL.
    • Grissinger, M.1    Rich, D.2
  • 6
    • 33745912350 scopus 로고    scopus 로고
    • Aplicação da Técnica HFMEA na Determinaç ão de Risco de Equipamentos Eletromédicos
    • Florence G, Calil SJ. Aplicação da Técnica HFMEA na Determinação de Risco de Equipamentos Eletromédicos (Application of HFMEA Technique in the Determination of Medical Device Risk) [on CD-ROM]. III Latin-American Congress on Biomedical Engineering; 2004.
    • (2004) III Latin-American Congress on Biomedical Engineering
    • Florence, G.1    Calil, S.J.2
  • 7
    • 0036580468 scopus 로고    scopus 로고
    • Using Health Care Failure Mode and Effect Analysis™: The VA National Center for Patient Safety's Prospective Risk Analysis System, Joint Commission for Accreditation of Healthcare Organizations
    • DeRosier J, Stalhandske E, Bagian JP, Nuddel T. Using Health Care Failure Mode and Effect Analysis™: The VA National Center for Patient Safety's Prospective Risk Analysis System, Joint Commission for Accreditation of Healthcare Organizations. J Qual Improv. 2002;28:248-267.
    • (2002) J Qual Improv , vol.28 , pp. 248-267
    • DeRosier, J.1    Stalhandske, E.2    Bagian, J.P.3    Nuddel, T.4
  • 10
    • 85039330527 scopus 로고    scopus 로고
    • Suporte Avançado de Vida em Cardiologia
    • ISBN 0-87493-634-9
    • American Heart Association. Suporte Avançado de Vida em Cardiologia. American Heart Association. 1997:4.1-4.20. (ISBN 0-87493-634-9).
    • (1997) American Heart Association


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.