Volumn 3, Issue , 2005, Pages 1919-1923

Arc flash hazards and electrical safety program implementation

Author keywords

Arc flash; Electrical hazards; Electrical safety; Hazard reduction; Protective clothing

Indexed keywords

ARC FLASH; ELECTRICAL HAZARDS; ELECTRICAL SAFETY; HAZARD REDUCTION;

EID: 33745879806     PISSN: 01972618     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IAS.2005.1518709     Document Type: Conference Paper
Times cited : (7)

References (19)
  • 2
    • 3242878353 scopus 로고    scopus 로고
    • Comparison of methods for selecting personal protective equipment for arc flash hazards
    • July/Aug
    • D.R. Doan, H.L. Floyd, and I.E. Neal, "Comparison of methods for selecting personal protective equipment for arc flash hazards", IEEE Transactions on Industry Applications, Vol 40, Issue 4, July/Aug 2004, pp 963-969.
    • (2004) IEEE Transactions on Industry Applications , vol.40 , Issue.4 , pp. 963-969
    • Doan, D.R.1    Floyd, H.L.2    Neal, I.E.3
  • 3
    • 0020125421 scopus 로고
    • The other electrical hazard: Electric arc blast burns
    • May/June
    • R.H. Lee, "The Other Electrical Hazard: Electric Arc Blast Burns", IEEE Transactions on Industrial Applications, Vol. 1A-18, No. 3, May/June 1982, p246.
    • (1982) IEEE Transactions on Industrial Applications , vol.1 A-18 , Issue.3 , pp. 246
    • Lee, R.H.1
  • 5
    • 0032805914 scopus 로고    scopus 로고
    • Testing update on protective clothing and equipment for electric arc exposure
    • Jan/Feb
    • R.L. Doughty, T.E. Neal, T.A. Dear, and A.M. Bingham, "Testing Update on Protective Clothing and Equipment for Electric Arc Exposure", IEEE Industry Applications Magazine, Vol 5 Issue 1, Jan/Feb 1999, pp. 37-49.
    • (1999) IEEE Industry Applications Magazine , vol.5 , Issue.1 , pp. 37-49
    • Doughty, R.L.1    Neal, T.E.2    Dear, T.A.3    Bingham, A.M.4
  • 6
    • 0033875952 scopus 로고    scopus 로고
    • Predicting incident energy to better manage the electric arc hazard on 600-V power distribution systems
    • Jan/Feb
    • R.L. Doughty, T.E. Neal and H.L. Floyd II, "Predicting Incident Energy to Better Manage the Electric Arc Hazard on 600-V Power Distribution Systems", IEEE Transactions on Industry Applications, Vol 36, Issue 1, Jan/Feb 2000, pp 257-269.
    • (2000) IEEE Transactions on Industry Applications , vol.36 , Issue.1 , pp. 257-269
    • Doughty, R.L.1    Neal, T.E.2    Floyd II, H.L.3
  • 8
    • 19144371688 scopus 로고    scopus 로고
    • Development of the guide for performing arc-flash hazard calculations
    • May-June
    • D.R. Doan, et. al., "Development of the Guide for Performing Arc-Flash Hazard Calculations", IEEE Industry Applications Magazine, Volume 11, Issue 3, May-June 2005, Page(s):30-39
    • (2005) IEEE Industry Applications Magazine , vol.11 , Issue.3 , pp. 30-39
    • Doan, D.R.1
  • 9
    • 12444287020 scopus 로고    scopus 로고
    • NFPA 70E, National Fire Protection Association, Boston, MA 02210
    • NFPA 70E, Standard for Electrical Safety in the Workplace, National Fire Protection Association, Boston, MA 02210.
    • Standard for Electrical Safety in the Workplace
  • 12
    • 19144368186 scopus 로고    scopus 로고
    • Specialized PPE testing for electric arc hazards beyond heat exposure - Shrapnel, pressure, and noise
    • May-June
    • T.E. Neal and R.F. Parry, "Specialized PPE testing for electric arc hazards beyond heat exposure - shrapnel, pressure, and noise", IEEE Industry Applications Magazine, Volume 11, Issue 3, May-June 2005, Page(s):49-53.
    • (2005) IEEE Industry Applications Magazine , vol.11 , Issue.3 , pp. 49-53
    • Neal, T.E.1    Parry, R.F.2
  • 13
    • 0032787651 scopus 로고    scopus 로고
    • Health implications of global electrification
    • Annals of the New York Academy of Sciences, October 30
    • EPRI (R.E.Wyzga and W. Lindroos), "Health Implications of Global Electrification", Occupational Electrical Injury: An International Symposium, Annals of the New York Academy of Sciences, Vol 888, October 30, 1999, pp 1-7.
    • (1999) Occupational Electrical Injury: An International Symposium , vol.888 , pp. 1-7
    • Wyzga, R.E.1    Lindroos, W.2
  • 15
    • 0141532099 scopus 로고    scopus 로고
    • A summary of arc flash hazard calculations
    • July-Aug.
    • D.R. Doan and R.A. Sweigart, "A Summary of Arc Flash Hazard Calculations", IEEE Transactions on Industry Applications, Volume 39, Issue 4, July-Aug. 2003, Page(s):1200-1204.
    • (2003) IEEE Transactions on Industry Applications , vol.39 , Issue.4 , pp. 1200-1204
    • Doan, D.R.1    Sweigart, R.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.