메뉴 건너뛰기




Volumn 39, Issue 7, 2006, Pages 767-769

Comparative study between the Light Cycler® and the PCR-restriction fragment length polymorphism in detecting factor V Leiden and factor II 20210G>A mutations

Author keywords

Factor II 20210G>A (FII 20210G>A); Factor V Leiden (FVL); Polymerase Chain Reaction (PCR); Restriction Fragment Length Polymorphism (RFLP); Roche Light Cycler (LC )

Indexed keywords

BLOOD CLOTTING FACTOR 5 LEIDEN; PROTHROMBIN;

EID: 33745868005     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2006.01.019     Document Type: Article
Times cited : (5)

References (10)
  • 1
    • 0028314865 scopus 로고
    • Mutation in blood coagulation factor V associated with resistance to activated protein C
    • Bertina R., Koeleman B., Koster T., et al. Mutation in blood coagulation factor V associated with resistance to activated protein C. Nature 369 (1994) 64-67
    • (1994) Nature , vol.369 , pp. 64-67
    • Bertina, R.1    Koeleman, B.2    Koster, T.3
  • 2
    • 0029850530 scopus 로고    scopus 로고
    • A common genetic variation in the 3′-untranslated region of the prothrombin gene is associated with elevated plasma prothrombin levels and an increase in venous thrombosis
    • Poort S., Rosendaal F., Reitsma P., and Bertina R. A common genetic variation in the 3′-untranslated region of the prothrombin gene is associated with elevated plasma prothrombin levels and an increase in venous thrombosis. Blood 88 (1996) 3698-3703
    • (1996) Blood , vol.88 , pp. 3698-3703
    • Poort, S.1    Rosendaal, F.2    Reitsma, P.3    Bertina, R.4
  • 3
    • 33745834510 scopus 로고    scopus 로고
    • TM-The smartest innovation for more efficient PCR
    • TM-The smartest innovation for more efficient PCR. Biochemica 2 (1998)
    • (1998) Biochemica , vol.2
  • 4
    • 0037253458 scopus 로고    scopus 로고
    • Evaluation of the Idaho Technology Light Cycler™ PCR for the direct detection of Mycobacterium tuberculosis in respiratory specimens
    • Heginbothom M., Magee J., and Flanagan P. Evaluation of the Idaho Technology Light Cycler™ PCR for the direct detection of Mycobacterium tuberculosis in respiratory specimens. Int. J. Tuberc. Lung Dis. 7 (2003) 78-83
    • (2003) Int. J. Tuberc. Lung Dis. , vol.7 , pp. 78-83
    • Heginbothom, M.1    Magee, J.2    Flanagan, P.3
  • 5
    • 0036707748 scopus 로고    scopus 로고
    • Detection of a novel point mutation of the prothrombin gene at position 20209
    • Warshawsky I., Hren C., Sercia L., et al. Detection of a novel point mutation of the prothrombin gene at position 20209. Diagn. Mol. Pathol. 11 (2002) 152-156
    • (2002) Diagn. Mol. Pathol. , vol.11 , pp. 152-156
    • Warshawsky, I.1    Hren, C.2    Sercia, L.3
  • 6
    • 0035002341 scopus 로고    scopus 로고
    • A novel point mutation in the 3′ region of the prothrombin gene at position 20221 in a Lebanese/Syrian family
    • Wylenzek M., Geisen C., Stapenhorst L., Wielckens K., and Klingler K. A novel point mutation in the 3′ region of the prothrombin gene at position 20221 in a Lebanese/Syrian family. Thromb. Haemost. 85 (2001) 943
    • (2001) Thromb. Haemost. , vol.85 , pp. 943
    • Wylenzek, M.1    Geisen, C.2    Stapenhorst, L.3    Wielckens, K.4    Klingler, K.5
  • 7
    • 0242691713 scopus 로고    scopus 로고
    • Prothrombin gene variants in non-Caucasians with fetal loss and intrauterine growth retardation
    • Schrijver I., Lenzi T., Jones C., Lay M., Druzin M., and Zehnder J. Prothrombin gene variants in non-Caucasians with fetal loss and intrauterine growth retardation. J. Med. Diagn. 5 (2003) 250-253
    • (2003) J. Med. Diagn. , vol.5 , pp. 250-253
    • Schrijver, I.1    Lenzi, T.2    Jones, C.3    Lay, M.4    Druzin, M.5    Zehnder, J.6
  • 8
    • 0043127232 scopus 로고    scopus 로고
    • Evaluation of the Roche Light Cycler; a simple and rapid method for direct detection of factor V Leiden and prothrombin G20210A genotypes from blood samples without the need for DNA extraction
    • Cooper P., Cooper S., Smith J., Kitchen S., and Makris M. Evaluation of the Roche Light Cycler; a simple and rapid method for direct detection of factor V Leiden and prothrombin G20210A genotypes from blood samples without the need for DNA extraction. Blood Coagul. Fibrinolysis 14 (2003) 499-503
    • (2003) Blood Coagul. Fibrinolysis , vol.14 , pp. 499-503
    • Cooper, P.1    Cooper, S.2    Smith, J.3    Kitchen, S.4    Makris, M.5
  • 9
    • 33745846571 scopus 로고    scopus 로고
    • Medicine and Healthcare Products Regulatory Agency, Roche Lightcycler (PCR) System. Evaluation Report Number MHRA 03093, 2003.
  • 10
    • 33745835229 scopus 로고    scopus 로고
    • Saour T, Sheereen A, Saour B, Saour J, Mammo L. Is The Light Cycler-real time PCR as reliable as the conventional PCR? Our experience. Proceedings of the 18th International Congress on Thrombosis in Pathophysiology of Haemostasis and Thrombosis; June 2004; 33 (Suppl. 2): P0139, p113.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.