메뉴 건너뛰기




Volumn 22, Issue 7, 2006, Pages 781-786

Hybrid Fixation Improves Structural Properties of a Free Tendon Anterior Cruciate Ligament Reconstruction

Author keywords

Anterior cruciate ligament reconstruction; Hybrid fixation; Structural properties

Indexed keywords

ANIMAL TISSUE; ANTERIOR CRUCIATE LIGAMENT; ARTICLE; BIODEGRADABILITY; BIOSORPTION; CONTROLLED STUDY; FEMUR; FLEXOR TENDON; HUMAN; HUMAN TISSUE; LIGAMENT SURGERY; NONHUMAN; STEADY STATE; TENSILE STRENGTH;

EID: 33745817445     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2006.03.018     Document Type: Article
Times cited : (14)

References (25)
  • 1
    • 1242343973 scopus 로고    scopus 로고
    • Hamstring anterior cruciate ligament reconstruction. A comparison of bioabsorbable interference screw and endobutton-post fixation
    • Ma C.B., Francis K., Towers J., Irrgang J., Fu F.H., and Harner C.H. Hamstring anterior cruciate ligament reconstruction. A comparison of bioabsorbable interference screw and endobutton-post fixation. Arthroscopy 20 (2004) 122-128
    • (2004) Arthroscopy , vol.20 , pp. 122-128
    • Ma, C.B.1    Francis, K.2    Towers, J.3    Irrgang, J.4    Fu, F.H.5    Harner, C.H.6
  • 2
    • 0036873168 scopus 로고    scopus 로고
    • The effect of soft-tissue graft fixation in anterior cruciate ligament reconstruction on graft-tunnel motion under anterior tibial loading
    • Tsuda E., Fukuda Y., Loh J.C., Debski R.E., Fu F.H., and Woo S.L. The effect of soft-tissue graft fixation in anterior cruciate ligament reconstruction on graft-tunnel motion under anterior tibial loading. Arthroscopy 18 (2002) 960-967
    • (2002) Arthroscopy , vol.18 , pp. 960-967
    • Tsuda, E.1    Fukuda, Y.2    Loh, J.C.3    Debski, R.E.4    Fu, F.H.5    Woo, S.L.6
  • 3
    • 0035121512 scopus 로고    scopus 로고
    • Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation
    • Nagarkatti D.G., McKeon B.P., Donahue B.S., and Fulkerson J.P. Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29 (2001) 67-71
    • (2001) Am J Sports Med , vol.29 , pp. 67-71
    • Nagarkatti, D.G.1    McKeon, B.P.2    Donahue, B.S.3    Fulkerson, J.P.4
  • 4
    • 0032950678 scopus 로고    scopus 로고
    • Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts
    • Magen H.E., Howell S.M., and Hull M.L. Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27 (1999) 35-43
    • (1999) Am J Sports Med , vol.27 , pp. 35-43
    • Magen, H.E.1    Howell, S.M.2    Hull, M.L.3
  • 5
    • 0036524466 scopus 로고    scopus 로고
    • Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques. The impact of fixation level and fixation method under cyclic loading
    • Scheffler S.U., Sudkamp N.P., Gockenjan A., Hoffmann R.F., and Weiler A. Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques. The impact of fixation level and fixation method under cyclic loading. Arthroscopy 18 (2002) 304-315
    • (2002) Arthroscopy , vol.18 , pp. 304-315
    • Scheffler, S.U.1    Sudkamp, N.P.2    Gockenjan, A.3    Hoffmann, R.F.4    Weiler, A.5
  • 6
    • 0036821542 scopus 로고    scopus 로고
    • Correlation of bone tunnel diameter with quadrupled hamstring graft fixation strength using a biodegradable interference screw
    • Steenlage E., Brand Jr. J.C., Johnson D.L., and Caborn D.N. Correlation of bone tunnel diameter with quadrupled hamstring graft fixation strength using a biodegradable interference screw. Arthroscopy 18 (2002) 901-907
    • (2002) Arthroscopy , vol.18 , pp. 901-907
    • Steenlage, E.1    Brand Jr., J.C.2    Johnson, D.L.3    Caborn, D.N.4
  • 7
    • 0034820029 scopus 로고    scopus 로고
    • Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel
    • Selby J.B., Johnson D.L., Hester P., and Caborn D.N. Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel. Am J Sports Med 29 (2001) 614-619
    • (2001) Am J Sports Med , vol.29 , pp. 614-619
    • Selby, J.B.1    Johnson, D.L.2    Hester, P.3    Caborn, D.N.4
  • 8
    • 0034267003 scopus 로고    scopus 로고
    • [Current aspects of anchoring hamstring tendon transplants in cruciate ligament surgery]
    • Weiler A., Scheffler S.U., and Sudkamp N.P. [Current aspects of anchoring hamstring tendon transplants in cruciate ligament surgery]. Chirurg 71 (2000) 1034-1044
    • (2000) Chirurg , vol.71 , pp. 1034-1044
    • Weiler, A.1    Scheffler, S.U.2    Sudkamp, N.P.3
  • 9
    • 0035324096 scopus 로고    scopus 로고
    • The EndoPearl device increases fixation strength and eliminates construct slippage of hamstring tendon grafts with interference screw fixation
    • Weiler A., Richter M., Schmidmaier G., Kandziora F., and Sudkamp N.P. The EndoPearl device increases fixation strength and eliminates construct slippage of hamstring tendon grafts with interference screw fixation. Arthroscopy 17 (2001) 353-359
    • (2001) Arthroscopy , vol.17 , pp. 353-359
    • Weiler, A.1    Richter, M.2    Schmidmaier, G.3    Kandziora, F.4    Sudkamp, N.P.5
  • 10
    • 0030912837 scopus 로고    scopus 로고
    • The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability. Evaluation using a robotic testing system
    • Ishibashi Y., Rudy T.W., Livesay G.A., Stone J.D., Fu F.H., and Woo S.L. The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability. Evaluation using a robotic testing system. Arthroscopy 13 (1997) 177-182
    • (1997) Arthroscopy , vol.13 , pp. 177-182
    • Ishibashi, Y.1    Rudy, T.W.2    Livesay, G.A.3    Stone, J.D.4    Fu, F.H.5    Woo, S.L.6
  • 11
    • 0942268959 scopus 로고    scopus 로고
    • Augmentation of femoral fixation in hamstring anterior cruciate ligament reconstruction with a bioabsorbable bead. A prospective single-blind randomized clinical trial
    • Arneja S., Froese W., and MacDonald P. Augmentation of femoral fixation in hamstring anterior cruciate ligament reconstruction with a bioabsorbable bead. A prospective single-blind randomized clinical trial. Am J Sports Med 32 (2004) 159-163
    • (2004) Am J Sports Med , vol.32 , pp. 159-163
    • Arneja, S.1    Froese, W.2    MacDonald, P.3
  • 12
    • 14644401133 scopus 로고    scopus 로고
    • Investigation of a hybrid method of soft tissue graft fixation for anterior cruciate ligament reconstruction
    • Au A.G., Otto D.D., Raso V.J., and Amirfazli A. Investigation of a hybrid method of soft tissue graft fixation for anterior cruciate ligament reconstruction. Knee 12 (2005) 149-153
    • (2005) Knee , vol.12 , pp. 149-153
    • Au, A.G.1    Otto, D.D.2    Raso, V.J.3    Amirfazli, A.4
  • 13
    • 0034536261 scopus 로고    scopus 로고
    • Biomechanical comparisons of anterior cruciate ligament. Reconstruction procedures with flexor tendon graft
    • Miyata K., Yasuda K., Kondo E., Nakano H., Kimura S., and Hara N. Biomechanical comparisons of anterior cruciate ligament. Reconstruction procedures with flexor tendon graft. J Orthop Sci 5 (2000) 585-592
    • (2000) J Orthop Sci , vol.5 , pp. 585-592
    • Miyata, K.1    Yasuda, K.2    Kondo, E.3    Nakano, H.4    Kimura, S.5    Hara, N.6
  • 14
    • 0029704294 scopus 로고    scopus 로고
    • Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees. Influence of insertion torque, tunnel-bone block gap, and interference
    • Brown G.A., Pena F., Grontvedt T., Labadie D., and Engebretsen L. Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees. Influence of insertion torque, tunnel-bone block gap, and interference. Knee Surg Sports Traumatol Arthrosc 3 (1996) 238-244
    • (1996) Knee Surg Sports Traumatol Arthrosc , vol.3 , pp. 238-244
    • Brown, G.A.1    Pena, F.2    Grontvedt, T.3    Labadie, D.4    Engebretsen, L.5
  • 15
    • 0022140070 scopus 로고
    • The mechanical properties of human flexor tendons in relation to artificial tendons
    • Pring D.J., Amis A.A., and Coombs R.R. The mechanical properties of human flexor tendons in relation to artificial tendons. J Hand Surg [Br] 10 (1985) 331-336
    • (1985) J Hand Surg [Br] , vol.10 , pp. 331-336
    • Pring, D.J.1    Amis, A.A.2    Coombs, R.R.3
  • 16
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions
    • Noyes F.R., Butler D.L., Grood E.S., Zernicke R.F., and Hefzy M.S. Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg Am 66 (1984) 344-352
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 344-352
    • Noyes, F.R.1    Butler, D.L.2    Grood, E.S.3    Zernicke, R.F.4    Hefzy, M.S.5
  • 17
    • 0001453963 scopus 로고
    • Cross-sectional area measurement for tendon specimens. A comparison of several methods
    • Ellis D.G. Cross-sectional area measurement for tendon specimens. A comparison of several methods. J Biomech 2 (1969) 175-186
    • (1969) J Biomech , vol.2 , pp. 175-186
    • Ellis, D.G.1
  • 18
    • 0032727741 scopus 로고    scopus 로고
    • The effect of cyclic displacement on the biomechanical characteristics of anterior cruciate ligament reconstructions
    • Yamanaka M., Yasuda K., Tohyama H., Nakano H., and Wada T. The effect of cyclic displacement on the biomechanical characteristics of anterior cruciate ligament reconstructions. Am J Sports Med 27 (1999) 772-777
    • (1999) Am J Sports Med , vol.27 , pp. 772-777
    • Yamanaka, M.1    Yasuda, K.2    Tohyama, H.3    Nakano, H.4    Wada, T.5
  • 19
    • 0027380876 scopus 로고
    • The strength of the central third patellar tendon graft. A biomechanical study
    • discussion, 823-824
    • Cooper D.E., Deng X.H., Burstein A.L., and Warren R.F. The strength of the central third patellar tendon graft. A biomechanical study. Am J Sports Med 21 (1993) 818-823 discussion, 823-824
    • (1993) Am J Sports Med , vol.21 , pp. 818-823
    • Cooper, D.E.1    Deng, X.H.2    Burstein, A.L.3    Warren, R.F.4
  • 20
  • 21
    • 0025782419 scopus 로고
    • Tensile properties of the human femur-anterior cruciate ligament-tibia complex. The effects of specimen age and orientation
    • Woo S.L., Hollis J.M., Adams D.J., Lyon R.M., and Takai S. Tensile properties of the human femur-anterior cruciate ligament-tibia complex. The effects of specimen age and orientation. Am J Sports Med 19 (1991) 217-225
    • (1991) Am J Sports Med , vol.19 , pp. 217-225
    • Woo, S.L.1    Hollis, J.M.2    Adams, D.J.3    Lyon, R.M.4    Takai, S.5
  • 23
    • 0028233969 scopus 로고
    • The measurement of elongation of anterior cruciate-ligament grafts in vivo
    • Beynnon B.D., Johnson R.J., Fleming B.C., et al. The measurement of elongation of anterior cruciate-ligament grafts in vivo. J Bone Joint Surg Am 76 (1994) 520-531
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 520-531
    • Beynnon, B.D.1    Johnson, R.J.2    Fleming, B.C.3
  • 24
    • 0034945610 scopus 로고    scopus 로고
    • The influence of tendon length and fit on the strength of a tendon-bone tunnel complex. A biomechanical and histologic study in the dog
    • Greis P.E., Burks R.T., Bachus K., and Luker M.G. The influence of tendon length and fit on the strength of a tendon-bone tunnel complex. A biomechanical and histologic study in the dog. Am J Sports Med 29 (2001) 493-497
    • (2001) Am J Sports Med , vol.29 , pp. 493-497
    • Greis, P.E.1    Burks, R.T.2    Bachus, K.3    Luker, M.G.4
  • 25
    • 0030800917 scopus 로고    scopus 로고
    • Integration of hamstring tendon graft with bone in reconstruction of the anterior cruciate ligament
    • Pinczewski L.A., Clingeleffer A.J., Otto D.D., Bonar S.F., and Corry I.S. Integration of hamstring tendon graft with bone in reconstruction of the anterior cruciate ligament. Arthroscopy 13 (1997) 641-643
    • (1997) Arthroscopy , vol.13 , pp. 641-643
    • Pinczewski, L.A.1    Clingeleffer, A.J.2    Otto, D.D.3    Bonar, S.F.4    Corry, I.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.