메뉴 건너뛰기




Volumn 2005, Issue , 2005, Pages 448-451

Foot and ground measurement using portable sensors

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; IMAGE SENSORS; OBJECT RECOGNITION; ORTHOPEDICS; PORTABLE EQUIPMENT; PROSTHETICS; SENSORY FEEDBACK;

EID: 33745790480     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICORR.2005.1501139     Document Type: Conference Paper
Times cited : (17)

References (13)
  • 1
    • 1542723639 scopus 로고    scopus 로고
    • Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
    • J. Blaya and H. Herr, "Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait," IEEE Transactions on neural systems and rehabilitation engineering, vol. 12, no. 12, pp. 24-31, 2004.
    • (2004) IEEE Transactions on Neural Systems and Rehabilitation Engineering , vol.12 , Issue.12 , pp. 24-31
    • Blaya, J.1    Herr, H.2
  • 2
    • 33745779863 scopus 로고    scopus 로고
    • Roll-over characteristics of human walking applications for artificial limbs
    • PhD Thesis, Evanston, North Western University, USA
    • A. Hansen, "Roll-over characteristics of human walking applications for artificial limbs," PhD Thesis, Evanston, North Western University, USA, Tech. Rep., 2002.
    • (2002) Tech. Rep.
    • Hansen, A.1
  • 3
    • 0036208446 scopus 로고    scopus 로고
    • Accelerometer and rate gyroscope measurement of kinematics: And inexpensive alternative to optical motion analysis systems
    • R. Mayagoita, A. Nene, and P. Veltink, "Accelerometer and rate gyroscope measurement of kinematics: and inexpensive alternative to optical motion analysis systems," Journal of Biomechanics, vol. 35, pp. 537-542, 2002.
    • (2002) Journal of Biomechanics , vol.35 , pp. 537-542
    • Mayagoita, R.1    Nene, A.2    Veltink, P.3
  • 4
    • 0023764557 scopus 로고
    • An integrated biomechnical analysis of normal stair ascent and descent
    • B. J. McFayden and D. A. Winter, "An integrated biomechnical analysis of normal stair ascent and descent," Journal of Biomechanics, vol. 21, no. 9, pp. 733-744, 1988.
    • (1988) Journal of Biomechanics , vol.21 , Issue.9 , pp. 733-744
    • McFayden, B.J.1    Winter, D.A.2
  • 7
    • 17444404200 scopus 로고    scopus 로고
    • Locomotor adaptations for changes in the slope of the walking surface
    • S. Prentice, E. Hasler, J. Groves, and J. Frank, "Locomotor adaptations for changes in the slope of the walking surface," Gait Posture, vol. 20, no. 3, pp. 255-265, 2004.
    • (2004) Gait Posture , vol.20 , Issue.3 , pp. 255-265
    • Prentice, S.1    Hasler, E.2    Groves, J.3    Frank, J.4
  • 8
    • 1242309931 scopus 로고    scopus 로고
    • Drift-free attitude estimation for accelerated rigid bodies
    • H. Rehbinder and X. Hu, "Drift-free attitude estimation for accelerated rigid bodies," Automatica, vol. 40, pp. 653-659, 2004.
    • (2004) Automatica , vol.40 , pp. 653-659
    • Rehbinder, H.1    Hu, X.2
  • 10
    • 0032998285 scopus 로고    scopus 로고
    • A practical gait analysis system using gyroscopes
    • K. Tong and M. Granat, "A practical gait analysis system using gyroscopes," Medical and Engineering Physics, no. 21, pp. 87-94, 1999.
    • (1999) Medical and Engineering Physics , Issue.21 , pp. 87-94
    • Tong, K.1    Granat, M.2
  • 12
    • 0037213330 scopus 로고    scopus 로고
    • Three dimensional inertial sensing of foot movement for automatic tuning of a two-channel implantable drop foot simulator
    • P. Veltink, P. Slycke, J. Hemsens, R. Buschman, G. Bulstra, and H. Hermens, "Three dimensional inertial sensing of foot movement for automatic tuning of a two-channel implantable drop foot simulator." Medical Engineering and Physics, vol. 25, pp. 21-28, 2003.
    • (2003) Medical Engineering and Physics , vol.25 , pp. 21-28
    • Veltink, P.1    Slycke, P.2    Hemsens, J.3    Buschman, R.4    Bulstra, G.5    Hermens, H.6
  • 13
    • 0026327984 scopus 로고
    • Lower extremity angle measurement with accelerometers - Error and sensitivity analysis
    • A. Willemsen, C. Frigo, and H. Boom, "Lower extremity angle measurement with accelerometers - error and sensitivity analysis," IEEE Transactions on Biomedical Engineering, vol. 38, no. 12, pp. 1186-1193, 1991.
    • (1991) IEEE Transactions on Biomedical Engineering , vol.38 , Issue.12 , pp. 1186-1193
    • Willemsen, A.1    Frigo, C.2    Boom, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.