메뉴 건너뛰기




Volumn 15, Issue 4, 2006, Pages 509-514

A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARM; ARTICLE; BICEPS BRACHII MUSCLE; BIOMECHANICS; CONTROLLED STUDY; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE; SURGICAL TECHNIQUE; SUTURE; TENDON INJURY; TENDON RUPTURE;

EID: 33745764296     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2005.09.020     Document Type: Article
Times cited : (96)

References (26)
  • 4
    • 0021999510 scopus 로고
    • Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment
    • Baker B.E., and Bierwagen D. Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment. J Bone Joint Surg Am 67 (1985) 414-417
    • (1985) J Bone Joint Surg Am , vol.67 , pp. 414-417
    • Baker, B.E.1    Bierwagen, D.2
  • 5
    • 0027438072 scopus 로고
    • Repair of avulsed insertion of biceps. A new technique in four cases
    • Barnes S.J., Coleman S.G., and Gilpin D. Repair of avulsed insertion of biceps. A new technique in four cases. J Bone Joint Surg Br 75 (1993) 938-939
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 938-939
    • Barnes, S.J.1    Coleman, S.G.2    Gilpin, D.3
  • 6
    • 0031811227 scopus 로고    scopus 로고
    • Distal biceps brachii tendon repair. An in vitro biomechanical study of tendon reattachment
    • Berlet G.C., Johnson J.A., Milne A.D., Patterson S.D., and King G.J. Distal biceps brachii tendon repair. An in vitro biomechanical study of tendon reattachment. Am J Sports Med 26 (1998) 428-432
    • (1998) Am J Sports Med , vol.26 , pp. 428-432
    • Berlet, G.C.1    Johnson, J.A.2    Milne, A.D.3    Patterson, S.D.4    King, G.J.5
  • 7
    • 0000959743 scopus 로고
    • A simplified method for reinsertion of the distal biceps brachii tendon
    • Boyd H.B., and Anderson L.D. A simplified method for reinsertion of the distal biceps brachii tendon. J Bone Joint Surg Am 43 (1961) 1041-1043
    • (1961) J Bone Joint Surg Am , vol.43 , pp. 1041-1043
    • Boyd, H.B.1    Anderson, L.D.2
  • 8
    • 0000981828 scopus 로고
    • Rupture of biceps brachii-a conservative method of treatment
    • Carroll R.E., and Hamilton L.R. Rupture of biceps brachii-a conservative method of treatment. J Bone Joint Surg Am 49 (1967) 1016
    • (1967) J Bone Joint Surg Am , vol.49 , pp. 1016
    • Carroll, R.E.1    Hamilton, L.R.2
  • 10
    • 84924496495 scopus 로고
    • An etiologic factor in tear of the distal tendon of the biceps brachii. a report of two cases
    • Davis W.M., and Yassine Z. An etiologic factor in tear of the distal tendon of the biceps brachii. a report of two cases. J Bone Joint Surg Am 38 (1956) 1365-1368
    • (1956) J Bone Joint Surg Am , vol.38 , pp. 1365-1368
    • Davis, W.M.1    Yassine, Z.2
  • 12
    • 0025354980 scopus 로고
    • Proximal radioulnar synostosis after repair of distal biceps brachii rupture by the two-incision technique. Report of four cases
    • Failla J.M., Amadio P.C., Morrey B.F., and Beckenbaugh R.D. Proximal radioulnar synostosis after repair of distal biceps brachii rupture by the two-incision technique. Report of four cases. Clin Orthop Relat Res (1990) 133-136
    • (1990) Clin Orthop Relat Res , pp. 133-136
    • Failla, J.M.1    Amadio, P.C.2    Morrey, B.F.3    Beckenbaugh, R.D.4
  • 14
    • 0033730019 scopus 로고    scopus 로고
    • Complications of repair of the distal biceps tendon with the modified two-incision technique
    • Kelly E.W., Morrey B.F., and O'Driscoll S.W. Complications of repair of the distal biceps tendon with the modified two-incision technique. J Bone Joint Surg Am 82 (2000) 1575-1581
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1575-1581
    • Kelly, E.W.1    Morrey, B.F.2    O'Driscoll, S.W.3
  • 15
    • 0037347246 scopus 로고    scopus 로고
    • The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site
    • Kousa P., Jarvinen T.L., Vihavainen M., Kannus P., and Jarvinen M. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: femoral site. Am J Sports Med 31 (2003) 174-181
    • (2003) Am J Sports Med , vol.31 , pp. 174-181
    • Kousa, P.1    Jarvinen, T.L.2    Vihavainen, M.3    Kannus, P.4    Jarvinen, M.5
  • 16
    • 1242338852 scopus 로고    scopus 로고
    • A new technique. in vitro suture anchor fixation has superior yield strength to bone tunnel fixation for distal biceps tendon repair
    • Lemos S.E., Ebramzedeh E., and Kvitne R.S. A new technique. in vitro suture anchor fixation has superior yield strength to bone tunnel fixation for distal biceps tendon repair. Am J Sports Med 32 (2004) 406-410
    • (2004) Am J Sports Med , vol.32 , pp. 406-410
    • Lemos, S.E.1    Ebramzedeh, E.2    Kvitne, R.S.3
  • 17
    • 0030038531 scopus 로고    scopus 로고
    • Repair of the distal biceps tendon using suture anchors and an anterior approach
    • Lintner S., and Fischer T. Repair of the distal biceps tendon using suture anchors and an anterior approach. Clin Orthop Relat Res (1996) 116-119
    • (1996) Clin Orthop Relat Res , pp. 116-119
    • Lintner, S.1    Fischer, T.2
  • 18
    • 0023910189 scopus 로고
    • Rupture of the tendon of the long head of the biceps brachii. Surgical versus nonsurgical treatment
    • Mariani E.M., Cofield R.H., Askew L.J., Li G.P., and Chao E.Y. Rupture of the tendon of the long head of the biceps brachii. Surgical versus nonsurgical treatment. Clin Orthop Relat Res (1988) 233-239
    • (1988) Clin Orthop Relat Res , pp. 233-239
    • Mariani, E.M.1    Cofield, R.H.2    Askew, L.J.3    Li, G.P.4    Chao, E.Y.5
  • 19
    • 0000527795 scopus 로고
    • The treatment of ruptures of the distal biceps brachii tendon
    • Meherin J.M., and Kilgore E.S. The treatment of ruptures of the distal biceps brachii tendon. Am J Surg 99 (1960) 636-640
    • (1960) Am J Surg , vol.99 , pp. 636-640
    • Meherin, J.M.1    Kilgore, E.S.2
  • 22
    • 0021945724 scopus 로고
    • Rupture of the distal tendon of the biceps brachii. A biomechanical study
    • Morrey B.F., Askew L.J., An K.N., and Dobyns J.H. Rupture of the distal tendon of the biceps brachii. A biomechanical study. J Bone Joint Surg Am 67 (1985) 418-421
    • (1985) J Bone Joint Surg Am , vol.67 , pp. 418-421
    • Morrey, B.F.1    Askew, L.J.2    An, K.N.3    Dobyns, J.H.4
  • 23
    • 0036099683 scopus 로고    scopus 로고
    • Surgical repair of distal biceps tendon ruptures. a biomechanical comparison of two techniques
    • Pereira D.S., Kvitne R.S., Liang M., Giacobetti F.B., and Ebramzadeh E. Surgical repair of distal biceps tendon ruptures. a biomechanical comparison of two techniques. Am J Sports Med 30 (2002) 432-436
    • (2002) Am J Sports Med , vol.30 , pp. 432-436
    • Pereira, D.S.1    Kvitne, R.S.2    Liang, M.3    Giacobetti, F.B.4    Ebramzadeh, E.5
  • 24
    • 0036849727 scopus 로고    scopus 로고
    • Distal biceps tendon ruptures. incidence, demographics, and the effect of smoking
    • Safran M.R., and Graham S.M. Distal biceps tendon ruptures. incidence, demographics, and the effect of smoking. Clin Orthop Relat Res (2002) 275-283
    • (2002) Clin Orthop Relat Res , pp. 275-283
    • Safran, M.R.1    Graham, S.M.2
  • 25
    • 0029301439 scopus 로고
    • The distal biceps tendon. Two potential mechanisms involved in its rupture: arterial supply and mechanical impingement
    • Seiler III J.G., Parker L.M., Chamberland P.D., Sherbourne G.M., and Carpenter W.A. The distal biceps tendon. Two potential mechanisms involved in its rupture: arterial supply and mechanical impingement. J Shoulder Elbow Surg 4 (1995) 149-156
    • (1995) J Shoulder Elbow Surg , vol.4 , pp. 149-156
    • Seiler III, J.G.1    Parker, L.M.2    Chamberland, P.D.3    Sherbourne, G.M.4    Carpenter, W.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.