메뉴 건너뛰기




Volumn 23, Issue 5, 2006, Pages 89-93

Shaking table test of coupled system of transmission lines and towers

Author keywords

Coupling system; Line; Seismic response; Shaking table test; Transmission tower

Indexed keywords

COUPLINGS; DYNAMIC RESPONSE; ELECTRIC LINES; ELECTRIC POWER TRANSMISSION; MATHEMATICAL MODELS; SEISMIC WAVES; VIBRATIONS (MECHANICAL);

EID: 33745759952     PISSN: 10004750     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (10)
  • 1
    • 0020126755 scopus 로고
    • Loadings for electrical transmission structures
    • American Society of Civil Engineers Committee on Electrical Transmission Structures
    • American Society of Civil Engineers Committee on Electrical Transmission Structures. Loadings for electrical transmission structures[J]. ASCE Journal of Structural Division, 1982, 108(5): 1088-1105.
    • (1982) ASCE Journal of Structural Division , vol.108 , Issue.5 , pp. 1088-1105
  • 2
    • 0004321269 scopus 로고
    • Guidelines for electrical transmission line structural loading
    • American Society of Civil Engineers, ASCE Manuals and Reports on Engineering Practice No.74, New York
    • American Society of Civil Engineers. Guidelines for Electrical Transmission Line Structural Loading[R]. ASCE Manuals and Reports on Engineering Practice No.74, New York, 1991.
    • (1991)
  • 3
    • 10044242216 scopus 로고    scopus 로고
    • Calculation and analysis for transmission tower with flexible web number
    • Chinese source
    • Yang Lixian. Calculation and analysis for transmission tower with flexible web number[J]. Engineering Mechanics, 1996, 13(Sup.): 46-51. (in Chinese)
    • (1996) Engineering Mechanics , vol.13 , Issue.SUPPL. , pp. 46-51
    • Yang, L.1
  • 4
    • 0017535049 scopus 로고
    • Longitudinal load analysis of transmission line systems
    • Mozer J D. Longitudinal load analysis of transmission line systems[J]. IEEE Transactions on Power Apparatus and Systems, 1977, PAS-96(5): 1657-1665.
    • (1977) IEEE Transactions on Power Apparatus and Systems , vol.PAS-96 , Issue.5 , pp. 1657-1665
    • Mozer, J.D.1
  • 5
    • 33745759017 scopus 로고    scopus 로고
    • Technical code for designing 110-500 KV overhead transmission lines
    • DL/T5092-1999, East China Electric Power Design Institute, Beijing: China Electronics Publishing House, Chinese source
    • East China Electric Power Design Institute. DL/T5092-1999, Technical code for designing 110-500 KV overhead transmission lines[S]. Beijing: China Electronics Publishing House, 1999. (in Chinese)
    • (1999)
  • 6
    • 10044299302 scopus 로고
    • Simplified aseismic calculation for large-span self-supporting transmission tower system
    • Chinese source
    • Li Hongnan, Lu Ming, Wang Qianxin. Simplified aseismic calculation for large-span self-supporting transmission tower system[J]. Earthquake Engineering and Engineering Vibration, 1990, 10(2): 81-89. (in Chinese)
    • (1990) Earthquake Engineering and Engineering Vibration , vol.10 , Issue.2 , pp. 81-89
    • Li, H.1    Lu, M.2    Wang, Q.3
  • 7
    • 33745761035 scopus 로고    scopus 로고
    • Simplified seismic calculation method for coupled system of transmission lines and their supporting towers
    • Chinese source
    • Li Hongnan, Shi Wenlong, Wang Suyan. Simplified seismic calculation method for coupled system of transmission lines and their supporting towers[J]. Special Structures, 2002, 19(3): 58-61. (in Chinese)
    • (2002) Special Structures , vol.19 , Issue.3 , pp. 58-61
    • Li, H.1    Shi, W.2    Wang, S.3
  • 8
    • 0010613118 scopus 로고    scopus 로고
    • Dynamic character of large-span transmission tower system
    • Chinese source
    • Li Hongnan, Wang Qianxin. Dynamic character of large-span transmission tower system[J]. China Civil Engineering Journal, 1997, 30(5): 28-36. (in Chinese)
    • (1997) China Civil Engineering Journal , vol.30 , Issue.5 , pp. 28-36
    • Li, H.1    Wang, Q.2
  • 9
    • 33745742597 scopus 로고    scopus 로고
    • Simplified aseicmic calculation method considering effects of lines on transmission towers
    • Chinese source
    • Li Hongnan, Shi Wenlong, Jia Lianguang. Simplified aseicmic calculation method considering effects of lines on transmission towers[J]. Journal of Vibration Engineering, 2003, 16(2): 234-237. (in Chinese)
    • (2003) Journal of Vibration Engineering , vol.16 , Issue.2 , pp. 234-237
    • Li, H.1    Shi, W.2    Jia, L.3
  • 10
    • 4344669062 scopus 로고    scopus 로고
    • The effect of lines on transmission tower system and simplified calculation method
    • Chinese source
    • Li Hongnan, Shi Wenlong, Jia Lianguang. The effect of lines on transmission tower system and simplified calculation method[J]. Journal of Vibration and Shock, 2004, 23(2): 1-7. (in Chinese)
    • (2004) Journal of Vibration and Shock , vol.23 , Issue.2 , pp. 1-7
    • Li, H.1    Shi, W.2    Jia, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.