메뉴 건너뛰기




Volumn 12, Issue 1, 2006, Pages 31-35

Cerebral aneurysm perforations during treatment with detachable coils. Use of remodelling balloon inflation to achieve hemostasis

Author keywords

Brain aneurysm; Complications; Embolization

Indexed keywords

ABCIXIMAB; CLOPIDOGREL; PLATINUM; PROPOFOL; PROTAMINE;

EID: 33745750235     PISSN: 11239344     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (12)
  • 1
    • 0036847314 scopus 로고    scopus 로고
    • Cerebral Aneurysm Perforations Complicating Therapy with Guglielmi Detachable Coils: A Meta-Analysis
    • Cloft HJ, Kallmes DF: Cerebral Aneurysm Perforations Complicating Therapy with Guglielmi Detachable Coils: A Meta-Analysis. Am J Neuroradiol 23: 1706-1709, 2002.
    • (2002) Am J Neuroradiol , vol.23 , pp. 1706-1709
    • Cloft, H.J.1    Kallmes, D.F.2
  • 2
    • 0034816927 scopus 로고    scopus 로고
    • Rupture of intracranial aneurysms during endovascular coiling: Management and outcomes
    • Levy E, Koebbe CJ et al: Rupture of intracranial aneurysms during endovascular coiling: Management and outcomes. Neurosurgery 49: 807-811, 2001.
    • (2001) Neurosurgery , vol.49 , pp. 807-811
    • Levy, E.1    Koebbe, C.J.2
  • 3
    • 0031831282 scopus 로고    scopus 로고
    • Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coils
    • McDougall CG, Halbach VV et al: Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coils. J Neurosurg 89: 87-92, 1998.
    • (1998) J Neurosurg , vol.89 , pp. 87-92
    • McDougall, C.G.1    Halbach, V.V.2
  • 4
    • 0032471962 scopus 로고    scopus 로고
    • Rupture during treatment of recently ruptured aneurysms with Guglielmi electrodetachable coils
    • Ricolfi F, Le Guerinel C et al: Rupture during treatment of recently ruptured aneurysms with Guglielmi electrodetachable coils. Am J Neuroradiol 19: 1653-1658, 1998.
    • (1998) Am J Neuroradiol , vol.19 , pp. 1653-1658
    • Ricolfi, F.1    Le Guerinel, C.2
  • 5
    • 0002900381 scopus 로고    scopus 로고
    • Aneurysm rupture during GDC treatment: Incidence, management and outcome
    • Valavanis A, Machado E, Chen JJ: Aneurysm rupture during GDC treatment: incidence, management and outcome. Neuroradiology 38 (Suppl 2): 45, 1996.
    • (1996) Neuroradiology , vol.38 , Issue.SUPPL. 2 , pp. 45
    • Valavanis, A.1    Machado, E.2    Chen, J.J.3
  • 6
    • 1842296356 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of acute intracranial aneurysm: Perioperative anatomical and clinical outcome in 403 patients J
    • Viñuela F, Duckwiler G, Mawad M: Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86: 475-482, 1997.
    • (1997) Neurosurg , vol.86 , pp. 475-482
    • Viñuela, F.1    Duckwiler, G.2    Mawad, M.3
  • 7
    • 0011308679 scopus 로고    scopus 로고
    • Rupture of cerebral aneurysms during endovascular treatment with electrolytically detachable coils: Incidence, management, and outcome
    • Coumans JV, McGrail KM, Watson V: Rupture of cerebral aneurysms during endovascular treatment with electrolytically detachable coils: incidence, management, and outcome. J Neurosurg 90: 204A, 1999.
    • (1999) J Neurosurg , vol.204 A , pp. 90
    • Coumans, J.V.1    McGrail, K.M.2    Watson, V.3
  • 8
    • 0035189016 scopus 로고    scopus 로고
    • Aneurysmal rupture during embolization with Guglielmi detachable coils: Causes, management, and outcome
    • Doerfler A, Wanke I et al: Aneurysmal rupture during embolization with Guglielmi detachable coils: causes, management, and outcome. Am J Neuroradiol 22: 1825-1832, 2001.
    • (2001) Am J Neuroradiol , vol.22 , pp. 1825-1832
    • Doerfler, A.1    Wanke, I.2
  • 9
    • 0026078619 scopus 로고
    • Management of vascular perforations that occur during neurointerventional procedures
    • Halbach VV, Higashida RT et al: Management of vascular perforations that occur during neurointerventional procedures. Am J Neuroradiol 12: 319-327, 1991.
    • (1991) Am J Neuroradiol , vol.12 , pp. 319-327
    • Halbach, V.V.1    Higashida, R.T.2
  • 10
    • 0036120089 scopus 로고    scopus 로고
    • Surgical salvage of microcatheter-induced aneurysm perforation during coil embolization
    • Short JG, Marx WF et al: Surgical salvage of microcatheter-induced aneurysm perforation during coil embolization. Am J Neuroradiol 23: 682-685, 2002.
    • (2002) Am J Neuroradiol , vol.23 , pp. 682-685
    • Short, J.G.1    Marx, W.F.2
  • 11
    • 0034859836 scopus 로고    scopus 로고
    • Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: Incidence, outcome and risk factors
    • Sluzewski M, Bosch JA et al: Rupture of intracranial aneurysms during treatment with Guglielmi detachable coils: incidence, outcome and risk factors. J Neurosurg 94: 238-240, 2001.
    • (2001) J Neurosurg , vol.94 , pp. 238-240
    • Sluzewski, M.1    Bosch, J.A.2
  • 12
    • 0033831795 scopus 로고    scopus 로고
    • Use of a second microcatheter in the management of a perforation during endovascular treatment of a cerebral aneurysm
    • Willinsky R, terBrugge K: Use of a second microcatheter in the management of a perforation during endovascular treatment of a cerebral aneurysm. Am J Neuroradiol 21: 1537-1539, 2000.
    • (2000) Am J Neuroradiol , vol.21 , pp. 1537-1539
    • Willinsky, R.1    terBrugge, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.