메뉴 건너뛰기




Volumn 117, Issue 1, 2006, Pages 230-235

Fabrication and application of a novel modified electrode based on β-cyclodextrin/ferrocenecarboxylic acid inclusion complex

Author keywords

Cyclodextrin; Ascorbic acid; Ferrocenecarboxylic acid; Fresh egg white; Inclusion complex

Indexed keywords

CROSSLINKING; CYCLIC VOLTAMMETRY; OLIGOMERS; ORGANIC ACIDS; OXIDATION; SIGNAL TO NOISE RATIO; SOLUTIONS;

EID: 33745727635     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1551-2916.2005.00666.x     Document Type: Article
Times cited : (13)

References (17)
  • 1
    • 0023510094 scopus 로고
    • Development of an on-line glucose sensor for fermentation monitoring
    • Brooks S.L., Ashby R.E., and Turner A.P.E. Development of an on-line glucose sensor for fermentation monitoring. Biosensors 3 (1987-1988) 45-46
    • (1987) Biosensors , vol.3 , pp. 45-46
    • Brooks, S.L.1    Ashby, R.E.2    Turner, A.P.E.3
  • 2
    • 0026122963 scopus 로고
    • Structure of an ordered self-assembled monolayer of docosyl mercaptan on gold (□) by surface X-ray diffraction
    • Samant M.G., Brown C.A., and Gordon J.G. Structure of an ordered self-assembled monolayer of docosyl mercaptan on gold (□) by surface X-ray diffraction. Langmuir 7 (1991) 437-439
    • (1991) Langmuir , vol.7 , pp. 437-439
    • Samant, M.G.1    Brown, C.A.2    Gordon, J.G.3
  • 3
    • 0025231699 scopus 로고
    • Mixed ferrocene-glucose oxidase-carbon paste electrode for amperometric determination of glucose
    • Wang J., Wu L.H., Lu Z., Li R., and Sanchez J. Mixed ferrocene-glucose oxidase-carbon paste electrode for amperometric determination of glucose. Anal. Chim. Acta 228 (1990) 251-257
    • (1990) Anal. Chim. Acta , vol.228 , pp. 251-257
    • Wang, J.1    Wu, L.H.2    Lu, Z.3    Li, R.4    Sanchez, J.5
  • 4
    • 33646411187 scopus 로고
    • Preparation and properties of cyclodextrin-ferrocene inclusion complexes
    • Harada A., and Takahashi S. Preparation and properties of cyclodextrin-ferrocene inclusion complexes. J. Chem. Soc. Chem. Commun. 10 (1984) 645-657
    • (1984) J. Chem. Soc. Chem. Commun. , vol.10 , pp. 645-657
    • Harada, A.1    Takahashi, S.2
  • 5
    • 0034724820 scopus 로고    scopus 로고
    • β-Cyclodextrin-ferrocene inclusion complex modified carbon paste electrode for amperometric determination of ascorbic acid
    • Zhang G.R., Wang X.L., Shi X.W., and Sun T.L. β-Cyclodextrin-ferrocene inclusion complex modified carbon paste electrode for amperometric determination of ascorbic acid. Talanta 51 (2000) 1019-1025
    • (2000) Talanta , vol.51 , pp. 1019-1025
    • Zhang, G.R.1    Wang, X.L.2    Shi, X.W.3    Sun, T.L.4
  • 6
    • 0036135551 scopus 로고    scopus 로고
    • A nano-molar sensitive disposable biosensor for determination of dopamine
    • Tu Y.F., and Chen H.Y. A nano-molar sensitive disposable biosensor for determination of dopamine. Biosens. Bioelectron. 17 (2002) 19-24
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 19-24
    • Tu, Y.F.1    Chen, H.Y.2
  • 7
    • 2342592547 scopus 로고    scopus 로고
    • Amperometric glucose sensor based on enzyme-modified boron-doped diamond electrode by cross-linking method
    • Su L., Qiu X.P., Guo L.H., Zhang F.S., and Tung C.H. Amperometric glucose sensor based on enzyme-modified boron-doped diamond electrode by cross-linking method. Sens. Actuators B Chem. 99 (2004) 499-504
    • (2004) Sens. Actuators B Chem. , vol.99 , pp. 499-504
    • Su, L.1    Qiu, X.P.2    Guo, L.H.3    Zhang, F.S.4    Tung, C.H.5
  • 8
    • 0033138389 scopus 로고    scopus 로고
    • Electrochemical characterization of an enzyme electrode based on a ferrocene-containing redox polymer
    • Koide S., and Yokoyama K. Electrochemical characterization of an enzyme electrode based on a ferrocene-containing redox polymer. J. Electroanal. Chem. 468 (1999) 193-201
    • (1999) J. Electroanal. Chem. , vol.468 , pp. 193-201
    • Koide, S.1    Yokoyama, K.2
  • 9
    • 7444264608 scopus 로고    scopus 로고
    • Biocompatible glucose sensor prepared by modifying protein and vinyferrocene monomer composite membrane
    • Kurita R., Tabei H., and Iwasaki Y. Biocompatible glucose sensor prepared by modifying protein and vinyferrocene monomer composite membrane. Biosens. Bioelectron. 20 (2004) 518-523
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 518-523
    • Kurita, R.1    Tabei, H.2    Iwasaki, Y.3
  • 11
    • 0035976257 scopus 로고    scopus 로고
    • Carbon paste electrode spiked with ferrocene carboxylic acid and its application to the electroanalytic determination of ascorbic acid
    • Raoof J.B., Ojani R., and Kiani A. Carbon paste electrode spiked with ferrocene carboxylic acid and its application to the electroanalytic determination of ascorbic acid. J. Electroanal. Chem. 515 (2001) 45-51
    • (2001) J. Electroanal. Chem. , vol.515 , pp. 45-51
    • Raoof, J.B.1    Ojani, R.2    Kiani, A.3
  • 12
    • 4243322277 scopus 로고    scopus 로고
    • Ferrocene modified green pepper seed carbon paste bioelectrodes for the determination of ascorbic acid
    • Deng Z.F., Zhu Z.L., Yang Z.W., and Li T.H. Ferrocene modified green pepper seed carbon paste bioelectrodes for the determination of ascorbic acid. Chin. J. Anal. Chem. 27 (1999) 323-325
    • (1999) Chin. J. Anal. Chem. , vol.27 , pp. 323-325
    • Deng, Z.F.1    Zhu, Z.L.2    Yang, Z.W.3    Li, T.H.4
  • 13
    • 18544384217 scopus 로고    scopus 로고
    • Layer-by-layer assembled multiplayer films of redox polymers for electrocatalytic oxidation of ascorbic acid
    • Qian L., Gao Q., Song Y.H., Li Z., and Yang X.R. Layer-by-layer assembled multiplayer films of redox polymers for electrocatalytic oxidation of ascorbic acid. Sens. Actuators B Chem. 107 (2005) 303-310
    • (2005) Sens. Actuators B Chem. , vol.107 , pp. 303-310
    • Qian, L.1    Gao, Q.2    Song, Y.H.3    Li, Z.4    Yang, X.R.5
  • 14
    • 0034004797 scopus 로고    scopus 로고
    • Flow electrochemical determination of ascorbic acid in real samples using a glassy carbon electrode modified with a cellulose acetate film bearing 2,6-dichlorophenolindophenol
    • Florou A.B., Prodromidis M.I., Karayannis M.I., and Tzouwari-Karayani S.M. Flow electrochemical determination of ascorbic acid in real samples using a glassy carbon electrode modified with a cellulose acetate film bearing 2,6-dichlorophenolindophenol. Anal. Chim. Acta 409 (2000) 113-121
    • (2000) Anal. Chim. Acta , vol.409 , pp. 113-121
    • Florou, A.B.1    Prodromidis, M.I.2    Karayannis, M.I.3    Tzouwari-Karayani, S.M.4
  • 15
    • 0035974969 scopus 로고    scopus 로고
    • Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode
    • Castro S.S..L., Balbo V.R., Barbeira P.J.S., and Stradiotto N.R. Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode. Talanta 55 (2001) 249-254
    • (2001) Talanta , vol.55 , pp. 249-254
    • Castro, S.S..L.1    Balbo, V.R.2    Barbeira, P.J.S.3    Stradiotto, N.R.4
  • 16
    • 0345327818 scopus 로고    scopus 로고
    • Preparation of polypyrroleferrcyanide filmd modified carbon past electrode and its application on the elctrocatalytic determination of ascorbic acid
    • Raoof J.B., Ojani R., and Rashid-Nadimi S. Preparation of polypyrroleferrcyanide filmd modified carbon past electrode and its application on the elctrocatalytic determination of ascorbic acid. Electrochim. Acta 49 (2004) 271-280
    • (2004) Electrochim. Acta , vol.49 , pp. 271-280
    • Raoof, J.B.1    Ojani, R.2    Rashid-Nadimi, S.3
  • 17
    • 0028277744 scopus 로고
    • Microvoltammetric techniques and sensors for monitoring neurochemical dynamics in vivo-a review
    • O'Neill R.D. Microvoltammetric techniques and sensors for monitoring neurochemical dynamics in vivo-a review. Analyst 119 (1994) 767-779
    • (1994) Analyst , vol.119 , pp. 767-779
    • O'Neill, R.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.