메뉴 건너뛰기




Volumn 88, Issue 7, 2006, Pages 1642-1649

Contemporary posterior occipital fixation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICULAR CARTILAGE; BIOMECHANICS; CERVICAL SPINE; FRACTURE FIXATION; HUMAN; IMMOBILIZATION; INSTRUMENTATION; OCCIPITAL BONE; PRIORITY JOURNAL; REVIEW; SPINE STABILIZATION; SPINE SURGERY; SURGICAL TECHNIQUE; VERTEBRA BODY;

EID: 33745713034     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-200607000-00030     Document Type: Review
Times cited : (25)

References (30)
  • 4
    • 0014051192 scopus 로고
    • Occipito-cervical fusion. Indications, technique and results
    • Hamblen DL. Occipito-cervical fusion. Indications, technique and results. J Bone Joint Surg Br. 1967;49:33-45.
    • (1967) J Bone Joint Surg Br , vol.49 , pp. 33-45
    • Hamblen, D.L.1
  • 5
    • 21244448815 scopus 로고    scopus 로고
    • Indications for surgery and stabilization techniques of the occipitocervical junction
    • Vaccaro AR, Lim MR, Lee JY. Indications for surgery and stabilization techniques of the occipitocervical junction. Injury. 2005;36 Suppl 2:B44-53.
    • (2005) Injury , vol.36 , Issue.SUPPL. 2
    • Vaccaro, A.R.1    Lim, M.R.2    Lee, J.Y.3
  • 6
    • 0020316520 scopus 로고
    • The anatomic basis and development of segmental spinal instrumentation
    • Luque ER. The anatomic basis and development of segmental spinal instrumentation. Spine. 1982;7:256-9.
    • (1982) Spine , vol.7 , pp. 256-259
    • Luque, E.R.1
  • 7
    • 0024241191 scopus 로고
    • Occipito-cervical fusion reinforced by Luque's segmental spinal instrumentation for rheumatoid diseases
    • Itoh T, Tsuji H, Katoh Y, Yonezawa T, Kitagawa H. Occipito-cervical fusion reinforced by Luque's segmental spinal instrumentation for rheumatoid diseases. Spine. 1988;13:1234-8.
    • (1988) Spine , vol.13 , pp. 1234-1238
    • Itoh, T.1    Tsuji, H.2    Katoh, Y.3    Yonezawa, T.4    Kitagawa, H.5
  • 10
    • 0034014691 scopus 로고    scopus 로고
    • Occipitocervical stabilization for myelopathy in patients with rheumatoid arthritis. Implications of not bone-grafting
    • Moskovich R, Crockard HA, Shott S, Ransford AO. Occipitocervical stabilization for myelopathy in patients with rheumatoid arthritis. Implications of not bone-grafting. J Bone Joint Surg Am. 2000;82:349-65.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 349-365
    • Moskovich, R.1    Crockard, H.A.2    Shott, S.3    Ransford, A.O.4
  • 11
    • 0026036180 scopus 로고
    • Posterior occipitocervical fusion. A preliminary report of a new technique
    • Grob D, Dvorak J, Panjabi M, Froehlich M, Hayek J. Posterior occipitocervical fusion. A preliminary report of a new technique. Spine. 1991;16(3 Suppl):S17-24.
    • (1991) Spine , vol.16 , Issue.3 SUPPL.
    • Grob, D.1    Dvorak, J.2    Panjabi, M.3    Froehlich, M.4    Hayek, J.5
  • 12
    • 0031723499 scopus 로고    scopus 로고
    • Occipito-cervical fusion using posterior titanium plates
    • Lieberman IH, Webb JK. Occipito-cervical fusion using posterior titanium plates. Eur Spine J. 1998;7:308-12.
    • (1998) Eur Spine J , vol.7 , pp. 308-312
    • Lieberman, I.H.1    Webb, J.K.2
  • 13
    • 0027944270 scopus 로고
    • Occipitocervical fusion with posterior plate and screw instrumentation. A long-term follow-up study
    • Sasso RC, Jeanneret B, Fischer K, Magerl F. Occipitocervical fusion with posterior plate and screw instrumentation. A long-term follow-up study. Spine. 1994;19:2364-8.
    • (1994) Spine , vol.19 , pp. 2364-2368
    • Sasso, R.C.1    Jeanneret, B.2    Fischer, K.3    Magerl, F.4
  • 14
    • 0027515433 scopus 로고
    • Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique
    • Smith MD, Anderson P, Grady MS. Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique. Spine. 1993;18:1984-90.
    • (1993) Spine , vol.18 , pp. 1984-1990
    • Smith, M.D.1    Anderson, P.2    Grady, M.S.3
  • 15
    • 0032750036 scopus 로고    scopus 로고
    • Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques
    • Oda I, Abumi K, Sell LC, Haggerty CJ, Cunningham BW, McAfee PC. Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques. Spine. 1999;24:2377-82.
    • (1999) Spine , vol.24 , pp. 2377-2382
    • Oda, I.1    Abumi, K.2    Sell, L.C.3    Haggerty, C.J.4    Cunningham, B.W.5    McAfee, P.C.6
  • 16
    • 0033565624 scopus 로고    scopus 로고
    • Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems
    • Abumi K, Takada T, Shono Y, Kaneda K, Fujiya M. Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine. 1999;24:1425-34.
    • (1999) Spine , vol.24 , pp. 1425-1434
    • Abumi, K.1    Takada, T.2    Shono, Y.3    Kaneda, K.4    Fujiya, M.5
  • 18
    • 0026389684 scopus 로고
    • Complications of surgery at the craniovertebral junction-avoidance and management
    • Menezes AH. Complications of surgery at the craniovertebral junction-avoidance and management. Pediatr Neurosurg. 1991;17:254-66.
    • (1991) Pediatr Neurosurg , vol.17 , pp. 254-266
    • Menezes, A.H.1
  • 19
    • 0344211464 scopus 로고    scopus 로고
    • Occipitocervical reconstruction with the Ohio Medical Instruments Loop: Results of a multicenter evaluation in 30 cases
    • Singh SK, Rickards L, Apfelbaum RI, Huribert RJ, Maiman D, Fehlings MG. Occipitocervical reconstruction with the Ohio Medical Instruments Loop: results of a multicenter evaluation in 30 cases. J Neurosurg. 2003;98(3 Suppl):239-46.
    • (2003) J Neurosurg , vol.98 , Issue.3 SUPPL. , pp. 239-246
    • Singh, S.K.1    Rickards, L.2    Apfelbaum, R.I.3    Huribert, R.J.4    Maiman, D.5    Fehlings, M.G.6
  • 20
    • 18144435832 scopus 로고    scopus 로고
    • Anterior occiput-to-axis screw fixation: Part I: A case report, description of a new technique, and anatomical feasibility analysis
    • Dvorak MF, Fisher C, Boyd M, Johnson M, Greenhow R, Oxland TR. Anterior occiput-to-axis screw fixation: part I: a case report, description of a new technique, and anatomical feasibility analysis. Spine. 2003;28:E54-60.
    • (2003) Spine , vol.28
    • Dvorak, M.F.1    Fisher, C.2    Boyd, M.3    Johnson, M.4    Greenhow, R.5    Oxland, T.R.6
  • 21
    • 0037318214 scopus 로고    scopus 로고
    • Anterior occiput to axis screw fixation: Part II: A biomechanical comparison with posterior fixation techniques
    • Dvorak MF, Sekeramayi F, Zhu Q, Hoekema J, Fisher C, Boyd M, Goertzen DJ, Oxland TR. Anterior occiput to axis screw fixation: part II: a biomechanical comparison with posterior fixation techniques. Spine. 2003;28:239-45.
    • (2003) Spine , vol.28 , pp. 239-245
    • Dvorak, M.F.1    Sekeramayi, F.2    Zhu, Q.3    Hoekema, J.4    Fisher, C.5    Boyd, M.6    Goertzen, D.J.7    Oxland, T.R.8
  • 22
    • 0032524653 scopus 로고    scopus 로고
    • Quantitative anatomy of the occiput and the biomechanics of occipital screw fixation
    • Roberts DA, Doherty BJ, Heggeness MH. Quantitative anatomy of the occiput and the biomechanics of occipital screw fixation. Spine. 1998;23:1100-8.
    • (1998) Spine , vol.23 , pp. 1100-1108
    • Roberts, D.A.1    Doherty, B.J.2    Heggeness, M.H.3
  • 23
    • 0029765461 scopus 로고    scopus 로고
    • An anatomic study of the thickness of the occipital bone. Implications for occipitocervical instrumentation
    • Ebraheim NA, Lu J, Biyani A, Brown JA, Yeasting RA. An anatomic study of the thickness of the occipital bone. Implications for occipitocervical instrumentation. Spine. 1996;21:1725-30.
    • (1996) Spine , vol.21 , pp. 1725-1730
    • Ebraheim, N.A.1    Lu, J.2    Biyani, A.3    Brown, J.A.4    Yeasting, R.A.5
  • 27
    • 0032950211 scopus 로고    scopus 로고
    • Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: Preliminary results
    • Pait TG, Al-Mefty O, Boop FA, Arnautovic KI, Rahman S, Ceola W. Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results. J Neurosurg. 1999;90(1 Suppl):1-7.
    • (1999) J Neurosurg , vol.90 , Issue.1 SUPPL. , pp. 1-7
    • Pait, T.G.1    Al-Mefty, O.2    Boop, F.A.3    Arnautovic, K.I.4    Rahman, S.5    Ceola, W.6
  • 28
    • 0037442332 scopus 로고    scopus 로고
    • Occipitocervical fusion for rheumatoid arthritis using the inside-outside stabilization technique
    • Sandhu FA, Pait TG, Benzel E, Henderson FC. Occipitocervical fusion for rheumatoid arthritis using the inside-outside stabilization technique. Spine. 2003;28:414-9.
    • (2003) Spine , vol.28 , pp. 414-419
    • Sandhu, F.A.1    Pait, T.G.2    Benzel, E.3    Henderson, F.C.4
  • 29
    • 0029869526 scopus 로고    scopus 로고
    • Anatomic consideration of C2 pedicle screw placement
    • Ebraheim N, Rollins JR Jr, Xu R, Jackson WT. Anatomic consideration of C2 pedicle screw placement. Spine. 1996;21:691-5.
    • (1996) Spine , vol.21 , pp. 691-695
    • Ebraheim, N.1    Rollins Jr., J.R.2    Xu, R.3    Jackson, W.T.4
  • 30
    • 0031010622 scopus 로고    scopus 로고
    • Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison
    • Jones EL, Heller JG, Silcox DH, Hutton WC. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine. 1997;22:977-82.
    • (1997) Spine , vol.22 , pp. 977-982
    • Jones, E.L.1    Heller, J.G.2    Silcox, D.H.3    Hutton, W.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.