메뉴 건너뛰기




Volumn 117, Issue 1, 2006, Pages 274-281

Development of a voltammetric sensor for catechol in nanomolar levels using a modified electrode with Cu(phen)2(TCNQ)2 and PLL

Author keywords

Catechol; Poly l lysine; Tetracyanoquinodimethane; Voltammetric sensor

Indexed keywords

DIFFUSION; ELECTRODES; ELECTRONS; NANOTECHNOLOGY; OXIDATION; RATE CONSTANTS;

EID: 33745699651     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2005.11.042     Document Type: Article
Times cited : (32)

References (44)
  • 2
    • 1242328693 scopus 로고    scopus 로고
    • Electrocatalytic oxidation and selective detection of dopamine at a 5,5-ditetradecyl-2-(2-trimethyl-ammonioethyl)-1,3-dioxane bromide self-assembled bilayer membrane modified glassy carbon electrode
    • Lin X., and Gong J. Electrocatalytic oxidation and selective detection of dopamine at a 5,5-ditetradecyl-2-(2-trimethyl-ammonioethyl)-1,3-dioxane bromide self-assembled bilayer membrane modified glassy carbon electrode. Anal. Chim. Acta 507 (2004) 259-265
    • (2004) Anal. Chim. Acta , vol.507 , pp. 259-265
    • Lin, X.1    Gong, J.2
  • 3
    • 2942587273 scopus 로고    scopus 로고
    • Determination of serotonin, noradrenaline, dopamine and their metabolites in rat brain extracts and microdialysis samples by column liquid chromatography with fluorescence detection following derivatization with benzylamine and 1,2-diphenylethylenediamine
    • Yoshitake T., Kehr J., Yoshitake S., Fujino K., Nohta H., and Yamaguchi M. Determination of serotonin, noradrenaline, dopamine and their metabolites in rat brain extracts and microdialysis samples by column liquid chromatography with fluorescence detection following derivatization with benzylamine and 1,2-diphenylethylenediamine. J. Chromatogr. B 807 (2004) 177-183
    • (2004) J. Chromatogr. B , vol.807 , pp. 177-183
    • Yoshitake, T.1    Kehr, J.2    Yoshitake, S.3    Fujino, K.4    Nohta, H.5    Yamaguchi, M.6
  • 4
    • 0032733672 scopus 로고    scopus 로고
    • Species comparison of hepatic and pulmonary metabolism of benzene
    • Powley M.W., and Carloson G.P. Species comparison of hepatic and pulmonary metabolism of benzene. Toxicology 139 (1999) 207-217
    • (1999) Toxicology , vol.139 , pp. 207-217
    • Powley, M.W.1    Carloson, G.P.2
  • 5
    • 5444233673 scopus 로고    scopus 로고
    • Polyphenolic content and sensory properties of normal and high oleic acid peanuts
    • Talcott S.T., Passeretti S., Duncan C.E., and Gorbet D.W. Polyphenolic content and sensory properties of normal and high oleic acid peanuts. Food Chem. 90 (2005) 379-388
    • (2005) Food Chem. , vol.90 , pp. 379-388
    • Talcott, S.T.1    Passeretti, S.2    Duncan, C.E.3    Gorbet, D.W.4
  • 6
    • 0032854903 scopus 로고    scopus 로고
    • Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection
    • Cui H., He C., and Zhao G. Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection. J. Chromatogr. A 855 (1999) 171-179
    • (1999) J. Chromatogr. A , vol.855 , pp. 171-179
    • Cui, H.1    He, C.2    Zhao, G.3
  • 7
    • 0034629412 scopus 로고    scopus 로고
    • Gas chromatographic-mass spectrometric procedures for determination of the catechol-O-methyltransferase (COMT) activity and for detection of unstable catecholic metabolites in human and rat liver preparations after (COMT) catalyzed in statu nascendi derivatization using S-adenosylmethionine
    • Maurer H.H., Bickeboeller-Friedrich J., and Kraemer T. Gas chromatographic-mass spectrometric procedures for determination of the catechol-O-methyltransferase (COMT) activity and for detection of unstable catecholic metabolites in human and rat liver preparations after (COMT) catalyzed in statu nascendi derivatization using S-adenosylmethionine. J. Chromatogr. B 739 (2000) 325-335
    • (2000) J. Chromatogr. B , vol.739 , pp. 325-335
    • Maurer, H.H.1    Bickeboeller-Friedrich, J.2    Kraemer, T.3
  • 8
    • 0031006732 scopus 로고    scopus 로고
    • Analysis of phenolic compounds in industrial wastewater with high-performance liquid chromatography and post-column reaction detection
    • Fiehn O., and Jekel M. Analysis of phenolic compounds in industrial wastewater with high-performance liquid chromatography and post-column reaction detection. J. Chromatogr. A 769 (1997) 189-200
    • (1997) J. Chromatogr. A , vol.769 , pp. 189-200
    • Fiehn, O.1    Jekel, M.2
  • 9
    • 0037456078 scopus 로고    scopus 로고
    • Tris (2,2′-bipyridil) copper (II) chloride complex: a biomimetic tyrosinase catalyst in the amperometric sensor construction
    • Sotomayor M.D.P.T., Tanaka A.A., and Kubota L.T. Tris (2,2′-bipyridil) copper (II) chloride complex: a biomimetic tyrosinase catalyst in the amperometric sensor construction. Electrochim. Acta 48 (2003) 855-865
    • (2003) Electrochim. Acta , vol.48 , pp. 855-865
    • Sotomayor, M.D.P.T.1    Tanaka, A.A.2    Kubota, L.T.3
  • 10
    • 0034618840 scopus 로고    scopus 로고
    • Simultaneous determination of phenol isomers in binary mixtures by differential pulse voltammetry using carbon fibre electrode and neural network with pruning as a multivariate calibration tool
    • Carvalho R.M., Mello C., and Kubota L.T. Simultaneous determination of phenol isomers in binary mixtures by differential pulse voltammetry using carbon fibre electrode and neural network with pruning as a multivariate calibration tool. Anal. Chim. Acta 420 (2000) 109-121
    • (2000) Anal. Chim. Acta , vol.420 , pp. 109-121
    • Carvalho, R.M.1    Mello, C.2    Kubota, L.T.3
  • 11
    • 0344464873 scopus 로고    scopus 로고
    • HRP-based amperometric biosensor for the polyphenols determination in vegetables extract
    • Mello L.D., Stomayor M.D.P.T., and Kubota L.T. HRP-based amperometric biosensor for the polyphenols determination in vegetables extract. Sens. Actuators B: Chem. 96 (2003) 636-645
    • (2003) Sens. Actuators B: Chem. , vol.96 , pp. 636-645
    • Mello, L.D.1    Stomayor, M.D.P.T.2    Kubota, L.T.3
  • 13
    • 0023208226 scopus 로고
    • Chemically modified electrodes-a general overview
    • Redepenning J.G. Chemically modified electrodes-a general overview. Tracs-Trends Anal. Chem. 6 (1987) 18-22
    • (1987) Tracs-Trends Anal. Chem. , vol.6 , pp. 18-22
    • Redepenning, J.G.1
  • 14
    • 0037464513 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of dopamine at aluminum electrode modified with nickel pentacyanonitrosylferrate films, synthesized by electroless procedure
    • Razmi H., Agazadeh M., and Habibi-A B. Electrocatalytic oxidation of dopamine at aluminum electrode modified with nickel pentacyanonitrosylferrate films, synthesized by electroless procedure. J. Electroanal. Chem. 547 (2003) 25-33
    • (2003) J. Electroanal. Chem. , vol.547 , pp. 25-33
    • Razmi, H.1    Agazadeh, M.2    Habibi-A, B.3
  • 15
    • 0347295980 scopus 로고    scopus 로고
    • Iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin as a biomimetic catalyst of horseradish peroxidase on the electrode surface: an amperometric sensor for phenolic compound determinations
    • Damos F.S., Sotomayor M.D.T., Kubota L.T., Tanaka S.M.C.N., and Tanaka A.A. Iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin as a biomimetic catalyst of horseradish peroxidase on the electrode surface: an amperometric sensor for phenolic compound determinations. Analyst 128 (2003) 225-259
    • (2003) Analyst , vol.128 , pp. 225-259
    • Damos, F.S.1    Sotomayor, M.D.T.2    Kubota, L.T.3    Tanaka, S.M.C.N.4    Tanaka, A.A.5
  • 16
    • 33745734591 scopus 로고    scopus 로고
    • S. Mu, Catechol sensor using poly(aniline-co-o-aminophenol) as an electron transfer mediator, Biosens. Bioelectron., in press.
  • 17
    • 4043134375 scopus 로고    scopus 로고
    • Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped within a poly(thionine) film
    • Dempsey E., Diamond D., and Collier A. Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped within a poly(thionine) film. Biosens. Bioelectron. 20 (2004) 367-377
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 367-377
    • Dempsey, E.1    Diamond, D.2    Collier, A.3
  • 18
    • 2342522077 scopus 로고    scopus 로고
    • Amperometric tyrosinase based biosensor using an electropolymerized PTS-doped polypyrrole film as an entrapment support
    • Rajesh W., and Kaneto K. Amperometric tyrosinase based biosensor using an electropolymerized PTS-doped polypyrrole film as an entrapment support. React. Funct. Polym. 59 (2004) 163-169
    • (2004) React. Funct. Polym. , vol.59 , pp. 163-169
    • Rajesh, W.1    Kaneto, K.2
  • 19
    • 0141761156 scopus 로고    scopus 로고
    • Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors
    • Campuzano S., Serra B., Pedrero M., Villena F.J.M., and Pingarrón J.M. Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors. Anal. Chim. Acta 494 (2003) 187-197
    • (2003) Anal. Chim. Acta , vol.494 , pp. 187-197
    • Campuzano, S.1    Serra, B.2    Pedrero, M.3    Villena, F.J.M.4    Pingarrón, J.M.5
  • 21
    • 0032546973 scopus 로고    scopus 로고
    • Flow-injection determination of catechol with a new tyrosinase/DNA biosensor
    • Dantoni P., Serrano S.H.P., Brett A.M.O., and Gutz J.G.R. Flow-injection determination of catechol with a new tyrosinase/DNA biosensor. Anal. Chim. Acta 366 (1998) 137-145
    • (1998) Anal. Chim. Acta , vol.366 , pp. 137-145
    • Dantoni, P.1    Serrano, S.H.P.2    Brett, A.M.O.3    Gutz, J.G.R.4
  • 22
    • 0037669001 scopus 로고    scopus 로고
    • Characterization of graphite electrodes modified with laccase from Trametes versicolor and their use for bioelectrochemical monitoring of phenolic compounds in flow injection analysis
    • Haghighi B., Gordon L., Ruzgas T., and Josson L.J. Characterization of graphite electrodes modified with laccase from Trametes versicolor and their use for bioelectrochemical monitoring of phenolic compounds in flow injection analysis. Anal. Chim. Acta 487 (2003) 3-14
    • (2003) Anal. Chim. Acta , vol.487 , pp. 3-14
    • Haghighi, B.1    Gordon, L.2    Ruzgas, T.3    Josson, L.J.4
  • 23
    • 15944405638 scopus 로고    scopus 로고
    • Electrosynthesis and analytical performances of functionalized poly (pyrrole/β-cyclodextrin) films
    • Izacumen N., Bouchta D., Zejli H., Kaoutit M.E., Stalcup A.M., and Temsamani K.R. Electrosynthesis and analytical performances of functionalized poly (pyrrole/β-cyclodextrin) films. Talanta 66 (2005) 111-117
    • (2005) Talanta , vol.66 , pp. 111-117
    • Izacumen, N.1    Bouchta, D.2    Zejli, H.3    Kaoutit, M.E.4    Stalcup, A.M.5    Temsamani, K.R.6
  • 24
    • 0037170685 scopus 로고    scopus 로고
    • Development of an enzymeless biosensor for the determination of phenolic compounds
    • Sotomayor M.D.P.T., Tanaka A.A., and Kubota L.T. Development of an enzymeless biosensor for the determination of phenolic compounds. Anal. Chim. Acta 455 (2002) 215-223
    • (2002) Anal. Chim. Acta , vol.455 , pp. 215-223
    • Sotomayor, M.D.P.T.1    Tanaka, A.A.2    Kubota, L.T.3
  • 25
    • 5144232595 scopus 로고    scopus 로고
    • Voltammetric determination of 4-nitrophenol at a lithium tetracyanoethylenide (LiTCNE) modified glassy carbon electrode
    • Luz R.C.S., Damos F.S., Oliveira A.B., Beck J., and Kubota L.T. Voltammetric determination of 4-nitrophenol at a lithium tetracyanoethylenide (LiTCNE) modified glassy carbon electrode. Talanta 64 (2004) 935-942
    • (2004) Talanta , vol.64 , pp. 935-942
    • Luz, R.C.S.1    Damos, F.S.2    Oliveira, A.B.3    Beck, J.4    Kubota, L.T.5
  • 26
    • 16344378453 scopus 로고    scopus 로고
    • Development of a sensor based on tetracyanoethylenide (LiTCNE)/poly-l-lysine (PLL) for dopamine determination
    • Luz R.C.S., Damos F.S., Oliveira A.B., Beck J., and Kubota L.T. Development of a sensor based on tetracyanoethylenide (LiTCNE)/poly-l-lysine (PLL) for dopamine determination. Electrochim. Acta 50 (2005) 2675-2683
    • (2005) Electrochim. Acta , vol.50 , pp. 2675-2683
    • Luz, R.C.S.1    Damos, F.S.2    Oliveira, A.B.3    Beck, J.4    Kubota, L.T.5
  • 27
    • 25644453669 scopus 로고
    • Electrolyte effects on the cyclic voltammetry of TCNQ and TCNE
    • Khoo S.B., John K.F., and Stanley Pons. Electrolyte effects on the cyclic voltammetry of TCNQ and TCNE. J. Electroanal. Chem. 215 (1986) 273-285
    • (1986) J. Electroanal. Chem. , vol.215 , pp. 273-285
    • Khoo, S.B.1    John, K.F.2    Stanley Pons3
  • 28
    • 0008357662 scopus 로고
    • Bioelectrocatalysis at organic conducting salt electrodes. Use of hexamethylenetetratellurafulvalene tetracyanoquinodimethane (HMTTeF-TCNQ) as a versatile electrode material
    • Zhao S., and Lennox R. Bioelectrocatalysis at organic conducting salt electrodes. Use of hexamethylenetetratellurafulvalene tetracyanoquinodimethane (HMTTeF-TCNQ) as a versatile electrode material. J. Electroanal. Chem. 346 (1993) 161-173
    • (1993) J. Electroanal. Chem. , vol.346 , pp. 161-173
    • Zhao, S.1    Lennox, R.2
  • 29
    • 33947473326 scopus 로고
    • Substituted quinodimethans. 2. Anion-radical derivatives and complexes of 7,7,8,8-tetracyanoquinodimethane
    • Melby L.R., Harder R.J., Hertler W.R., Mahler W., Benson R.E., and Mochel W.E. Substituted quinodimethans. 2. Anion-radical derivatives and complexes of 7,7,8,8-tetracyanoquinodimethane. J. Am. Chem. Soc. 84 (1962) 3374-3387
    • (1962) J. Am. Chem. Soc. , vol.84 , pp. 3374-3387
    • Melby, L.R.1    Harder, R.J.2    Hertler, W.R.3    Mahler, W.4    Benson, R.E.5    Mochel, W.E.6
  • 30
    • 4243331343 scopus 로고
    • Spectroscopic and magnetic studies of 2 electrically conducting charge-transfer compounds of 7,7,8,8-tetracyanoquinodimethanide with cationic copper-chelates
    • Schwartz M., and Hatfield W.E. Spectroscopic and magnetic studies of 2 electrically conducting charge-transfer compounds of 7,7,8,8-tetracyanoquinodimethanide with cationic copper-chelates. Inorg. Chem. 26 (1987) 2823-2825
    • (1987) Inorg. Chem. , vol.26 , pp. 2823-2825
    • Schwartz, M.1    Hatfield, W.E.2
  • 31
    • 0007542451 scopus 로고    scopus 로고
    • 9,10-Anthraquinone modified glassy carbon electrode and its application for hemoglobin determination
    • Zhu Z., and Na-Qiang L. 9,10-Anthraquinone modified glassy carbon electrode and its application for hemoglobin determination. Electroanalysis 10 (1998) 643-646
    • (1998) Electroanalysis , vol.10 , pp. 643-646
    • Zhu, Z.1    Na-Qiang, L.2
  • 32
    • 0038755117 scopus 로고    scopus 로고
    • Comparative study of two spectrophotometric reagents for catechol analysis in guaraná seeds powder
    • Magna A., Salomão A.A., Vila M.M.D.C., and Tubino M. Comparative study of two spectrophotometric reagents for catechol analysis in guaraná seeds powder. J. Braz. Chem. Soc. 14 (2003) 129
    • (2003) J. Braz. Chem. Soc. , vol.14 , pp. 129
    • Magna, A.1    Salomão, A.A.2    Vila, M.M.D.C.3    Tubino, M.4
  • 33
    • 0031729623 scopus 로고    scopus 로고
    • Sensitivity, selectivity and reproducibility of some mediated electrochemical biosensors/sensors
    • Pandey P.C., Upadhyay S., Pathak H.C., and Pandey C.M.D. Sensitivity, selectivity and reproducibility of some mediated electrochemical biosensors/sensors. Anal. Lett. 31 (1998) 2327-2348
    • (1998) Anal. Lett. , vol.31 , pp. 2327-2348
    • Pandey, P.C.1    Upadhyay, S.2    Pathak, H.C.3    Pandey, C.M.D.4
  • 34
    • 0008862607 scopus 로고
    • Heterogeneous (chemically modified electrodes, polymer electrodes) vs. homogeneous catalysis of electrochemical reactions
    • Andrieux C.P., and Savéant J.M. Heterogeneous (chemically modified electrodes, polymer electrodes) vs. homogeneous catalysis of electrochemical reactions. J. Electroanal. Chem. 93 (1978) 163-168
    • (1978) J. Electroanal. Chem. , vol.93 , pp. 163-168
    • Andrieux, C.P.1    Savéant, J.M.2
  • 36
    • 0032489457 scopus 로고    scopus 로고
    • Capillary electrophoresis and electrochemical detection with a conventional detector cell
    • Durgbanshi A., and Kok W.T. Capillary electrophoresis and electrochemical detection with a conventional detector cell. J. Chromatogr. A 798 (1998) 289-296
    • (1998) J. Chromatogr. A , vol.798 , pp. 289-296
    • Durgbanshi, A.1    Kok, W.T.2
  • 37
    • 0037464513 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of dopamine at aluminum electrode modified with nickel pentacyanonitrosylferrate films, synthetized by electroless procedure
    • Razmi H., Agazadeh M., and Habibi-A B. Electrocatalytic oxidation of dopamine at aluminum electrode modified with nickel pentacyanonitrosylferrate films, synthetized by electroless procedure. J. Electroanal. Chem. 547 (2003) 25-33
    • (2003) J. Electroanal. Chem. , vol.547 , pp. 25-33
    • Razmi, H.1    Agazadeh, M.2    Habibi-A, B.3
  • 38
    • 14644408129 scopus 로고    scopus 로고
    • Electrochemical characteristic of dopamine oxidation at palladium hexacyanoferrate film, electroless plated on aluminum electrode
    • Razmi H., and Azadbakkht A. Electrochemical characteristic of dopamine oxidation at palladium hexacyanoferrate film, electroless plated on aluminum electrode. Electrochim. Acta 50 (2005) 2193-2201
    • (2005) Electrochim. Acta , vol.50 , pp. 2193-2201
    • Razmi, H.1    Azadbakkht, A.2
  • 39
    • 0002451602 scopus 로고
    • + reaction (four-member square scheme) for a heterogeneous reaction
    • + reaction (four-member square scheme) for a heterogeneous reaction. J. Electroanal. Chem. 124 (1981) 1-7
    • (1981) J. Electroanal. Chem. , vol.124 , pp. 1-7
    • Laviron, E.1
  • 40
    • 0000080659 scopus 로고
    • Electrochemical oxidation of 2,4,6-tri-tert-butylphenol
    • Richard J.A., Whitson P.E., and Evans D.H. Electrochemical oxidation of 2,4,6-tri-tert-butylphenol. J. Electroanal. Chem. 63 (1975) 311-327
    • (1975) J. Electroanal. Chem. , vol.63 , pp. 311-327
    • Richard, J.A.1    Whitson, P.E.2    Evans, D.H.3
  • 41
    • 0000713622 scopus 로고
    • Anodic oxidation pathways of phenolic compounds part 2. Stepwise electron transfers and coupled hydroxylations
    • Papouchado L., Sandford R.W., Petrie G., and Adams R.N. Anodic oxidation pathways of phenolic compounds part 2. Stepwise electron transfers and coupled hydroxylations. J. Electroanal. Chem. 65 (1975) 275-284
    • (1975) J. Electroanal. Chem. , vol.65 , pp. 275-284
    • Papouchado, L.1    Sandford, R.W.2    Petrie, G.3    Adams, R.N.4
  • 42
    • 0037430157 scopus 로고    scopus 로고
    • Amperometric phenol biosensor based on sol-gel silicate/Nafion composite film
    • Kim M.A., and Lee W.Y. Amperometric phenol biosensor based on sol-gel silicate/Nafion composite film. Anal. Chim. Acta 479 (2003) 143-150
    • (2003) Anal. Chim. Acta , vol.479 , pp. 143-150
    • Kim, M.A.1    Lee, W.Y.2
  • 43
    • 37049088122 scopus 로고
    • Recommendations for the definition, estimationand use of the detection limit
    • Analytical Methods Commitee. Recommendations for the definition, estimationand use of the detection limit. Analyst 112 (1987) 199-204
    • (1987) Analyst , vol.112 , pp. 199-204
    • Analytical Methods Commitee1
  • 44
    • 0020333986 scopus 로고
    • Guarana (paullinia-cupana var sorbilis)-ecological and social perspectives on an economic plant of the central amazon basin
    • Henman A.R. Guarana (paullinia-cupana var sorbilis)-ecological and social perspectives on an economic plant of the central amazon basin. J. Pharm. Pharmacol. 6 (1982) 311-338
    • (1982) J. Pharm. Pharmacol. , vol.6 , pp. 311-338
    • Henman, A.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.