Volumn 21, Issue 3, 2006, Pages 1148-1153

New fault-location method for a single multiterminal transmission line using synchronized phasor measurements

Author keywords

Bus impedance matrix; Electromagnetic Transients Program (EMTP); Fault analysis; Fault location; Synchronized phasor measurement

Indexed keywords

ALGORITHMIC LANGUAGES; COMPUTER SIMULATION; ELECTRIC CURRENT MEASUREMENT; ELECTRIC FAULT LOCATION; ITERATIVE METHODS; MATRIX ALGEBRA; TERMINALS (ELECTRIC); VOLTAGE MEASUREMENT;

EID: 33745698725     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2005.860273     Document Type: Article
Times cited : (66)

References (16)
  • 3
    • 0029185365 scopus 로고
    • "Development of a new fault location system for multi-terminal single transmission lines"
    • Jan
    • M. Abe, T. Emura, N. Otsuzuki, and M. Takeuchi, "Development of a new fault location system for multi-terminal single transmission lines," IEEE Trans. Power Del., vol. 10, no. 1, pp. 159-168, Jan. 1995.
    • (1995) IEEE Trans. Power Del. , vol.10 , Issue.1 , pp. 159-168
    • Abe, M.1    Emura, T.2    Otsuzuki, N.3    Takeuchi, M.4
  • 4
    • 0026896264 scopus 로고
    • "Development of a new fault location algorithm for multi-terminal two parallel transmission lines"
    • Jul
    • T. Nagasawa, M. Abe, N. Otsuzuki, T. Emura, Y. Jikihara, and M. Takeuchi, "Development of a new fault location algorithm for multi-terminal two parallel transmission lines," IEEE Trans. Power Del., vol. 7, no. 3, pp. 1516-1532, Jul. 1992.
    • (1992) IEEE Trans. Power Del. , vol.7 , Issue.3 , pp. 1516-1532
    • Nagasawa, T.1    Abe, M.2    Otsuzuki, N.3    Emura, T.4    Jikihara, Y.5    Takeuchi, M.6
  • 5
    • 0034171784 scopus 로고    scopus 로고
    • "Digital fault location for parallel double-circuit multi-terminal transmission lines"
    • Apr
    • T. Funabashi, H. Otoguro, Y. Mizuma, L. Dube, and A. Ametani, "Digital fault location for parallel double-circuit multi-terminal transmission lines," IEEE Trans. Power Del., vol. 15, no. 2, pp. 531-537, Apr. 2000.
    • (2000) IEEE Trans. Power Del. , vol.15 , Issue.2 , pp. 531-537
    • Funabashi, T.1    Otoguro, H.2    Mizuma, Y.3    Dube, L.4    Ametani, A.5
  • 9
    • 0028693830 scopus 로고
    • "Accuracy assessment of fault location algorithms on multi-phase EHV transmission lines"
    • L. Al-Dabbagh and A. Kalam, "Accuracy assessment of fault location algorithms on multi-phase EHV transmission lines," in Proc. Electrical Engineering Congr., vol. 1, 1994, pp. 177-184.
    • (1994) Proc. Electrical Engineering Congr. , vol.1 , pp. 177-184
    • Al-Dabbagh, L.1    Kalam, A.2
  • 10
    • 0035792227 scopus 로고    scopus 로고
    • "A fault location algorithm for transmission lines with tapped leg - PMU based approach"
    • C.-S. Yu, C.-W. Liu, and Y.-H. Lin, "A fault location algorithm for transmission lines with tapped leg - PMU based approach," in Proc. IEEE Power Eng. Soc. Summer Meeting, vol. 2, 2001, pp. 915-920.
    • (2001) Proc. IEEE Power Eng. Soc. Summer Meeting , vol.2 , pp. 915-920
    • Yu, C.-S.1    Liu, C.-W.2    Lin, Y.-H.3
  • 11
    • 0026623757 scopus 로고
    • "A new fault location technique for two- and three-terminal lines"
    • Jan
    • A. Girgis, D. Hart, and W. Peterson, "A new fault location technique for two- and three-terminal lines," IEEE Trans. Power Del., vol. 7, no. 1, pp. 98-107, Jan. 1992.
    • (1992) IEEE Trans. Power Del. , vol.7 , Issue.1 , pp. 98-107
    • Girgis, A.1    Hart, D.2    Peterson, W.3
  • 12
    • 0030150684 scopus 로고    scopus 로고
    • "New technique, based on voltages, for fault location on three-terminal transmission lines"
    • May
    • J. Minambres, I. Zamora, A. Mazon, M. Zorrozua, and R. Alvarez-Isasi, "New technique, based on voltages, for fault location on three-terminal transmission lines," Elect. Power Syst. Res., vol. 37-2, no. 2, pp. 143-151, May 1996.
    • (1996) Elect. Power Syst. Res. , vol.37-42 , Issue.2 , pp. 143-151
    • Minambres, J.1    Zamora, I.2    Mazon, A.3    Zorrozua, M.4    Alvarez-Isasi, R.5
  • 13
    • 17844364664 scopus 로고    scopus 로고
    • "Fault location scheme for a multi-terminal transmission line using synchronized voltage measurements"
    • Apr
    • S. Brahma, "Fault location scheme for a multi-terminal transmission line using synchronized voltage measurements," IEEE Trans. Power Del., vol. 20, no. 2, pp. 1325-1331, Apr. 2005.
    • (2005) IEEE Trans. Power Del. , vol.20 , Issue.2 , pp. 1325-1331
    • Brahma, S.1
  • 14
    • 34250222470 scopus 로고    scopus 로고
    • "A new fault location scheme for a two-terminal transmission line using synchronized phasor measurements"
    • Dallas, TX, May to be published
    • S. Brahma, "A new fault location scheme for a two-terminal transmission line using synchronized phasor measurements," in Proc. Transmission and Distribution Conf. Expo., Dallas, TX, May 2006, to be published.
    • (2006) Proc. Transmission and Distribution Conf. Expo.
    • Brahma, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.