메뉴 건너뛰기




Volumn , Issue , 2005, Pages 168-179

Stem design philosophies

Author keywords

[No Author keywords available]

Indexed keywords


EID: 33745689390     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1007/3-540-28924-0_22     Document Type: Chapter
Times cited : (3)

References (38)
  • 2
    • 0034914933 scopus 로고    scopus 로고
    • Is titanium so bad? Medium-term outcome of cemented titanium stems
    • Bowditch M, Villar R. Is titanium so bad? Medium-term outcome of cemented titanium stems.J Bone Joint Surg Br 2001; 83(5):680-5
    • (2001) J Bone Joint Surg Br , vol.83 , Issue.5 , pp. 680-685
    • Bowditch, M.1    Villar, R.2
  • 3
    • 0032767428 scopus 로고    scopus 로고
    • Barker TM Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces
    • Chen CQ, Scott W, Barker TM Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces. J Biomed Mater Res 1999; 48(4):440-6
    • (1999) J Biomed Mater Res , vol.48 , Issue.4 , pp. 440-446
    • Chen, C.Q.1    Scott, W.2
  • 4
    • 0036528664 scopus 로고    scopus 로고
    • Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry
    • Collis DK, Mohler CG. Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry. J Bone Joint Surg Am 2002; 84-A(4):586-92
    • (2002) J Bone Joint Surg Am , vol.84 A , Issue.4 , pp. 586-592
    • Collis, D.K.1    Mohler, C.G.2
  • 6
    • 0027407849 scopus 로고
    • Strength of cement-metal interfaces in fatigue: Comparison of smooth, porous and precoated specimens
    • Davies JP, Harris WH.Strength of cement-metal interfaces in fatigue: comparison of smooth, porous and precoated specimens. Clin Mater 1993; 12(2):121-6
    • (1993) Clin Mater , vol.12 , Issue.2 , pp. 121-126
    • Davies, J.P.1    Harris, W.H.2
  • 8
    • 0036901462 scopus 로고    scopus 로고
    • The effect of anteversion on femoral component stability assessed by radiostereometric analysis
    • Gill HS, Alfaro-Adrian J, Alfaro-Adrian C, McLardy-Smith P, Murray DW. The effect of anteversion on femoral component stability assessed by radiostereometric analysis. J Arthroplasty 2002; 17(8):997-1005
    • (2002) J Arthroplasty , vol.17 , Issue.8 , pp. 997-1005
    • Gill, H.S.1    Alfaro-Adrian, J.2    Alfaro-Adrian, C.3    McLardy-Smith, P.4    Murray, D.W.5
  • 9
    • 1642463522 scopus 로고    scopus 로고
    • Pain in the well-fixed, aseptic titanium hip replacement. The role of corrosion
    • Hallam P, Haddad F, Cobb J. Pain in the well-fixed, aseptic titanium hip replacement. The role of corrosion. J Bone Joint Surg Br. 2004; 86(1):27-30
    • (2004) J Bone Joint Surg Br. , vol.86 , Issue.1 , pp. 27-30
    • Hallam, P.1    Haddad, F.2    Cobb, J.3
  • 12
    • 0024947002 scopus 로고
    • Mathematical shape optimization of hip prosthesis design
    • Huiskes R, Boeklagen R. Mathematical shape optimization of hip prosthesis design. J Biomech. 1989; 22(8-9):793-804
    • (1989) J Biomech. , vol.22 , Issue.8-9 , pp. 793-804
    • Huiskes, R.1    Boeklagen, R.2
  • 13
    • 0027715365 scopus 로고    scopus 로고
    • Failed innovation in total hip replacement. Diagnosis and proposals for a cure
    • Huiskes R: Failed innovation in total hip replacement. Diagnosis and proposals for a cure. Acta Orthop Scand 64(6):699-716, 1996
    • (1996) Acta Orthop Scand , vol.64 , Issue.6 , pp. 699-716
    • Huiskes, R.1
  • 14
    • 0031733691 scopus 로고    scopus 로고
    • Migration, stem shape, and surface finish in cemented total hip arthroplasty
    • Huiskes R, Verdonschot N, Nivbrant B. Migration, stem shape, and surface finish in cemented total hip arthroplasty. Clin Orthop 1998; (355):103-12
    • (1998) Clin Orthop , Issue.355 , pp. 103-112
    • Huiskes, R.1    Verdonschot, N.2    Nivbrant, B.3
  • 15
    • 33645416562 scopus 로고    scopus 로고
    • Inferior design characteristics of the Captital Hip can be detected by numerical analysis
    • Janssen DW, Aquarius R, Stolk J, Verdonschot N. Inferior design characteristics of the Captital Hip can be detected by numerical analysis. ORS, 2005
    • (2005) ORS
    • Janssen, D.W.1    Aquarius, R.2    Stolk, J.3    Verdonschot, N.4
  • 16
    • 0027249705 scopus 로고
    • Ivarsson I.A prospective comparison of Butel and PCA hip arthroplasty
    • Jacobsson SA, Djerf K, Gillquist J, Hammerby S, Ivarsson I.A prospective comparison of Butel and PCA hip arthroplasty. J Bone Joint Surg Br 1993; 75(4):624-9
    • (1993) J Bone Joint Surg Br , vol.75 , Issue.4 , pp. 624-629
    • Jacobsson, S.A.1    Djerf, K.2    Gillquist, J.3    Hammerby, S.4
  • 17
    • 0036023508 scopus 로고    scopus 로고
    • Clinical outcome in total hip arthroplasty using a cemented titanium femoral prosthesis
    • Jergesen HE, Karlen JW. Clinical outcome in total hip arthroplasty using a cemented titanium femoral prosthesis. J Arthroplasty. 2002; 17(5):592-9
    • (2002) J Arthroplasty. , vol.17 , Issue.5 , pp. 592-599
    • Jergesen, H.E.1    Karlen, J.W.2
  • 19
    • 0033730521 scopus 로고    scopus 로고
    • Early loosening of a cemented hip endoprosthesis stem of titanium
    • Lichtinger TK, Schurmann N, Muller RT. Early loosening of a cemented hip endoprosthesis stem of titanium. Unfallchirurg 2000; 103(11):956-60
    • (2000) Unfallchirurg , vol.103 , Issue.11 , pp. 956-960
    • Lichtinger, T.K.1    Schurmann, N.2    Muller, R.T.3
  • 22
    • 1642532353 scopus 로고    scopus 로고
    • Oldenburg M the mechanism of loosening in cemented hip prostheses determined from long-term results
    • Muller RT, Heger I, Oldenburg M The mechanism of loosening in cemented hip prostheses determined from long-term results. Arch Orthop Trauma Surg. 1997; 116(1-2):41-5
    • (1997) Arch Orthop Trauma Surg. , vol.116 , Issue.1-2 , pp. 41-45
    • Muller, R.T.1    Heger, I.2
  • 23
    • 0028213581 scopus 로고
    • Total hip arthroplasty using isoelastic femoral stems. A seven-to nine-year follow-up in 108 patients
    • Niinimaki T, Puranen J, Jalovaara P. Total hip arthroplasty using isoelastic femoral stems. A seven-to nine-year follow-up in 108 patients. J Bone Joint Surg Br. 1994; 76(3):413-8
    • (1994) J Bone Joint Surg Br. , vol.76 , Issue.3 , pp. 413-418
    • Niinimaki, T.1    Puranen, J.2    Jalovaara, P.3
  • 24
    • 0033372584 scopus 로고    scopus 로고
    • Increased migration of the SHP prosthesis: Radiostereometric comparison with the Lubinus SP2 design in 40 cases
    • Nivbrant B, Karrholm J, Soderlund P. Increased migration of the SHP prosthesis: radiostereometric comparison with the Lubinus SP2 design in 40 cases. Acta Orthop Scand 1999; 70(6):569-77
    • (1999) Acta Orthop Scand , vol.70 , Issue.6 , pp. 569-577
    • Nivbrant, B.1    Karrholm, J.2    Soderlund, P.3
  • 25
    • 0035117516 scopus 로고    scopus 로고
    • The effect of femoral prosthesis design on cement strain in cemented total hip arthroplasty
    • Peters CL, Bachus KN, Craig MA, Higginbotham TO. The effect of femoral prosthesis design on cement strain in cemented total hip arthroplasty. J Arthroplasty. 2001; 16(2):216-24
    • (2001) J Arthroplasty. , vol.16 , Issue.2 , pp. 216-224
    • Peters, C.L.1    Bachus, K.N.2    Craig, M.A.3    Higginbotham, T.O.4
  • 32
    • 0035116592 scopus 로고    scopus 로고
    • Early failure of a roughened surface, precoated femoral component in total hip arthro-plasty
    • Sylvain GM, Kassab S, Coutts R, Santore R. Early failure of a roughened surface, precoated femoral component in total hip arthro-plasty. J Arthroplasty. 2001; 16(2):141-8
    • (2001) J Arthroplasty. , vol.16 , Issue.2 , pp. 141-148
    • Sylvain, G.M.1    Kassab, S.2    Coutts, R.3    Santore, R.4
  • 34
    • 0032534531 scopus 로고    scopus 로고
    • Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem-cement debonding
    • Verdonschot N, Tanck E, Huiskes R. Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem-cement debonding. J Biomed Mater Res 1998 15; 42(4):554-9
    • (1998) J Biomed Mater Res , vol.15-42 , Issue.4 , pp. 554-559
    • Verdonschot, N.1    Tanck, E.2    Huiskes, R.3
  • 35
    • 0032192224 scopus 로고    scopus 로고
    • Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage
    • Verdonschot N, Huiskes R. Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage. Biomaterials. 1998; 19(19):1773-9
    • (1998) Biomaterials. , vol.19 , Issue.19 , pp. 1773-1779
    • Verdonschot, N.1    Huiskes, R.2
  • 36
    • 0036791369 scopus 로고    scopus 로고
    • Do unloading periods affect migration characteristics of cemented femoral components? An in vitro evaluation with the Exeter stem
    • Verdonschot N, Barink M, Stolk J, Gardeniers JW, Schreurs BW. Do unloading periods affect migration characteristics of cemented femoral components? An in vitro evaluation with the Exeter stem. Acta Orthop Belg. 2002; 68(4):348-55
    • (2002) Acta Orthop Belg. , vol.68 , Issue.4 , pp. 348-355
    • Verdonschot, N.1    Barink, M.2    Stolk, J.3    Gardeniers, J.W.4    Schreurs, B.W.5
  • 37
    • 0038266838 scopus 로고    scopus 로고
    • Absence of surface roughness changes after insertion of one type of matte cemented femoral component during 2 to 15 years
    • Jun
    • von Knoch M, Bluhm A, Morlock M, von Foerster G.Absence of surface roughness changes after insertion of one type of matte cemented femoral component during 2 to 15 years. J Arthro-plasty. 2003 Jun;18(4):471-7.
    • (2003) J Arthro-plasty. , vol.18 , Issue.4 , pp. 471-477
    • Von Knoch, M.1    Bluhm, A.2    Morlock, M.3    Von Foerster, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.