메뉴 건너뛰기




Volumn 56, Issue 1, 2006, Pages 138-145

Quantitative CBV measurement from static T1 changes in tissue and correction for intravascular water exchange

Author keywords

Cerebral perfusion; Pulse sequence; Quantitative cerebral blood volume; Water exchange correction; Water exchange rate

Indexed keywords

FINANCE; HEMODYNAMICS;

EID: 33745685608     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20937     Document Type: Article
Times cited : (42)

References (38)
  • 2
    • 0030049425 scopus 로고    scopus 로고
    • Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: A preliminary analysis
    • Warach S, Dashe JF, Edelman RR. Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: a preliminary analysis. J Cereb Blood Flow Metab 1996;16:53-59.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 53-59
    • Warach, S.1    Dashe, J.F.2    Edelman, R.R.3
  • 4
    • 0032471609 scopus 로고    scopus 로고
    • Dynamic susceptibility contrast MR imaging of regional cerebral blood volume in Alzheimer disease: A promising alternative to nuclear medicine
    • Harris GJ, Lewis RF, Satlin A, English CD, Scott TM, Yurgelun-Todd DA, Renshaw PF. Dynamic susceptibility contrast MR imaging of regional cerebral blood volume in Alzheimer disease: a promising alternative to nuclear medicine. AJNR Am J Neuroradiol 1998;19:1727-1732.
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 1727-1732
    • Harris, G.J.1    Lewis, R.F.2    Satlin, A.3    English, C.D.4    Scott, T.M.5    Yurgelun-Todd, D.A.6    Renshaw, P.F.7
  • 7
    • 0029833429 scopus 로고    scopus 로고
    • In vivo regional cerebral blood volume: Quantitative assessment with 3D T1-weighted pre- and postcontrast MR imaging
    • Kuppusamy K, Lin W, Cizek GR, Haacke EM. In vivo regional cerebral blood volume: quantitative assessment with 3D T1-weighted pre- and postcontrast MR imaging. Radiology 1996;201:106-112.
    • (1996) Radiology , vol.201 , pp. 106-112
    • Kuppusamy, K.1    Lin, W.2    Cizek, G.R.3    Haacke, E.M.4
  • 8
    • 0027256155 scopus 로고
    • Quantification of regional blood volumes by rapid T1 mapping
    • Schwarzbauer C, Syha J, Haase A. Quantification of regional blood volumes by rapid T1 mapping. Magn Reson Med 1993;29:709-712.
    • (1993) Magn Reson Med , vol.29 , pp. 709-712
    • Schwarzbauer, C.1    Syha, J.2    Haase, A.3
  • 9
    • 0016254173 scopus 로고
    • Nuclear magnetic resonance transverse relaxation times of water protons in skeletal muscle
    • Hazlewood CF, Chang DC, Nichols BL, Woessner DE. Nuclear magnetic resonance transverse relaxation times of water protons in skeletal muscle. Biophys J 1974;14:583-606.
    • (1974) Biophys J , vol.14 , pp. 583-606
    • Hazlewood, C.F.1    Chang, D.C.2    Nichols, B.L.3    Woessner, D.E.4
  • 11
    • 0030056052 scopus 로고    scopus 로고
    • Cerebral blood volume maps with dynamic contrast-enhanced T1-weighted FLASH imaging: Normal values and preliminary clinical results
    • Hacklander T, Hofer M, Reichenbach JR, Rascher K, Furst G, Modder U. Cerebral blood volume maps with dynamic contrast-enhanced T1-weighted FLASH imaging: normal values and preliminary clinical results. J Comput Assist Tomogr 1996;20:532-539.
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 532-539
    • Hacklander, T.1    Hofer, M.2    Reichenbach, J.R.3    Rascher, K.4    Furst, G.5    Modder, U.6
  • 12
    • 12844284000 scopus 로고    scopus 로고
    • Effect of intravascular-to-extravascular water exchange on the determination-of blood-to-tissue transfer constant by magnetic resonance imaging
    • Cao Y, Brown SL, Knight RA, Fenstermacher JD, Ewing JR. Effect of intravascular-to-extravascular water exchange on the determination-of blood-to-tissue transfer constant by magnetic resonance imaging. Magn Reson Med 2005;53:282-293.
    • (2005) Magn Reson Med , vol.53 , pp. 282-293
    • Cao, Y.1    Brown, S.L.2    Knight, R.A.3    Fenstermacher, J.D.4    Ewing, J.R.5
  • 13
    • 0030951602 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging of capillary water permeability and regional blood volume with an intravascular MR contrast agent
    • Schwarzbauer C, Morrissey SP, Deichmann R, Hillenbrand C, Syha J, Adolf H, Noth U, Haase A. Quantitative magnetic resonance imaging of capillary water permeability and regional blood volume with an intravascular MR contrast agent. Magn Reson Med 1997;37:769-777.
    • (1997) Magn Reson Med , vol.37 , pp. 769-777
    • Schwarzbauer, C.1    Morrissey, S.P.2    Deichmann, R.3    Hillenbrand, C.4    Syha, J.5    Adolf, H.6    Noth, U.7    Haase, A.8
  • 14
    • 0014732355 scopus 로고
    • Time saving in measurement of NMR and EPR relaxation times
    • Look DC, Locker DR. Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum 1970;41:250-251.
    • (1970) Rev Sci Instrum , vol.41 , pp. 250-251
    • Look, D.C.1    Locker, D.R.2
  • 15
    • 0001480742 scopus 로고
    • Quantification of T1 valeus by snapshot FLASH NMR imaging
    • Deichmann R, Haase A. Quantification of T1 valeus by snapshot FLASH NMR imaging. J Magn Reson 1992;96:608-612.
    • (1992) J Magn Reson , vol.96 , pp. 608-612
    • Deichmann, R.1    Haase, A.2
  • 16
    • 20044384204 scopus 로고    scopus 로고
    • Dynamic susceptibility contrast perfusion imaging of radiation effects in normal-appearing brain tissue: Changes in the first-pass and recirculation phases
    • Lee MC, Cha S, Chang SM, Nelson SJ. Dynamic susceptibility contrast perfusion imaging of radiation effects in normal-appearing brain tissue: changes in the first-pass and recirculation phases. J Magn Reson Imaging 2005;21:683-693.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 683-693
    • Lee, M.C.1    Cha, S.2    Chang, S.M.3    Nelson, S.J.4
  • 17
    • 0345254996 scopus 로고    scopus 로고
    • Glioma grading: Sensitivity, specificity, and predictive values of perfusion MR imaging and proton MR spectroscopic imaging compared with conventional MR imaging
    • Law M, Yang S, Wang H, Babb JS, Johnson G, Cha S, Knopp EA, Zagzag D. Glioma grading: sensitivity, specificity, and predictive values of perfusion MR imaging and proton MR spectroscopic imaging compared with conventional MR imaging. AJNR Am J Neuroradiol 2003;24:1989-1998.
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 1989-1998
    • Law, M.1    Yang, S.2    Wang, H.3    Babb, J.S.4    Johnson, G.5    Cha, S.6    Knopp, E.A.7    Zagzag, D.8
  • 18
    • 21644453422 scopus 로고    scopus 로고
    • Perfusion MR imaging of brain tumors
    • Cha S. Perfusion MR imaging of brain tumors. Top Magn Reson Imaging 2004;15:279-289.
    • (2004) Top Magn Reson Imaging , vol.15 , pp. 279-289
    • Cha, S.1
  • 21
    • 0036191571 scopus 로고    scopus 로고
    • Variability of cerebral blood volume and oxygen extraction: Stages of cerebral haemodynamic impairment revisited
    • Derdeyn CP, Videen TO, Yundt KD, Fritsch SM, Carpenter DA, Grubb RL, Powers WJ. Variability of cerebral blood volume and oxygen extraction: stages of cerebral haemodynamic impairment revisited. Brain 2002;125(Pt 3):595-607.
    • (2002) Brain , vol.125 , Issue.PART 3 , pp. 595-607
    • Derdeyn, C.P.1    Videen, T.O.2    Yundt, K.D.3    Fritsch, S.M.4    Carpenter, D.A.5    Grubb, R.L.6    Powers, W.J.7
  • 22
    • 0033023491 scopus 로고    scopus 로고
    • Comparison of static and dynamic MRI techniques for the measurement of regional cerebral blood volume
    • Speck O, Chang L, Itti L, Itti E, Ernst T. Comparison of static and dynamic MRI techniques for the measurement of regional cerebral blood volume. Magn Reson Med 1999;41:1264-1268.
    • (1999) Magn Reson Med , vol.41 , pp. 1264-1268
    • Speck, O.1    Chang, L.2    Itti, L.3    Itti, E.4    Ernst, T.5
  • 23
    • 0035108686 scopus 로고    scopus 로고
    • Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRI
    • van Osch MJ, Vonken EJ, Bakker CJ, Viergever MA. Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRI. Magn Reson Med 2001;45:477-485.
    • (2001) Magn Reson Med , vol.45 , pp. 477-485
    • Van Osch, M.J.1    Vonken, E.J.2    Bakker, C.J.3    Viergever, M.A.4
  • 25
    • 0025213880 scopus 로고
    • Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging
    • Haase A. Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging. Magn Reson Med 1990;13:77-89.
    • (1990) Magn Reson Med , vol.13 , pp. 77-89
    • Haase, A.1
  • 27
    • 0032587954 scopus 로고    scopus 로고
    • Fast T1 mapping on a whole-body scanner
    • Deichmann R, Hahn D, Haase A. Fast T1 mapping on a whole-body scanner. Magn Reson Med 1999;42:206-209.
    • (1999) Magn Reson Med , vol.42 , pp. 206-209
    • Deichmann, R.1    Hahn, D.2    Haase, A.3
  • 28
    • 0023895482 scopus 로고
    • A comparison of one-shot and recovery methods in Tl imaging
    • Crawley AP, Henkelman RM. A comparison of one-shot and recovery methods in Tl imaging. Magn Reson Med 1988;7:23-34.
    • (1988) Magn Reson Med , vol.7 , pp. 23-34
    • Crawley, A.P.1    Henkelman, R.M.2
  • 29
    • 0032736504 scopus 로고    scopus 로고
    • Phantom and in vivo study of the Look-Locher T1 mapping method
    • Karlsson M, Nordell B. Phantom and in vivo study of the Look-Locher T1 mapping method. Magn Reson Imaging 1999;17:1481-1488.
    • (1999) Magn Reson Imaging , vol.17 , pp. 1481-1488
    • Karlsson, M.1    Nordell, B.2
  • 31
    • 0034839640 scopus 로고    scopus 로고
    • Usefulness of magnetic resonance-derived quantitative measurements of cerebral blood flow and volume in prediction of infarct growth in hyperacute stroke
    • Grandin CB, Duprez TP, Smith AM, Mataigne F, Peelers A, Oppenheim C, Cosnard G. Usefulness of magnetic resonance-derived quantitative measurements of cerebral blood flow and volume in prediction of infarct growth in hyperacute stroke. Stroke 2001;32:1147-1153.
    • (2001) Stroke , vol.32 , pp. 1147-1153
    • Grandin, C.B.1    Duprez, T.P.2    Smith, A.M.3    Mataigne, F.4    Peelers, A.5    Oppenheim, C.6    Cosnard, G.7
  • 32
    • 0038119637 scopus 로고    scopus 로고
    • Changes in human cerebral blood flow and cerebral blood volume during hypercapnia and hypocapnia measured by positron emission tomography
    • Ito H, Kanno I, Ibaraki M, Hatazawa J, Miura S. Changes in human cerebral blood flow and cerebral blood volume during hypercapnia and hypocapnia measured by positron emission tomography. J Cereb Blood Flow Metab 2003;23:665-670.
    • (2003) J Cereb Blood Flow Metab , vol.23 , pp. 665-670
    • Ito, H.1    Kanno, I.2    Ibaraki, M.3    Hatazawa, J.4    Miura, S.5
  • 33
    • 8444235982 scopus 로고    scopus 로고
    • Validation of quantitative accuracy of the post-injection transmission-based and transmissionless attenuation correction techniques in neurological FDG-PET
    • Kaneko K, Kuwabara Y, Sasaki M, Koga H, Abe K, Baba S, Hayashi K, Honda H. Validation of quantitative accuracy of the post-injection transmission-based and transmissionless attenuation correction techniques in neurological FDG-PET. Nucl Med Commun 2004;25:1095-1102.
    • (2004) Nucl Med Commun , vol.25 , pp. 1095-1102
    • Kaneko, K.1    Kuwabara, Y.2    Sasaki, M.3    Koga, H.4    Abe, K.5    Baba, S.6    Hayashi, K.7    Honda, H.8
  • 35
    • 0018080066 scopus 로고
    • Local cerebral blood volume response to carbon dioxide in man
    • Greenberg JH, Alavi A, Reivich M, Kuhl D, Uzzell B. Local cerebral blood volume response to carbon dioxide in man. Circ Res 1978;43:324-331.
    • (1978) Circ Res , vol.43 , pp. 324-331
    • Greenberg, J.H.1    Alavi, A.2    Reivich, M.3    Kuhl, D.4    Uzzell, B.5
  • 36
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • Rempp KA, Brix G, Wenz F, Becker CR, Guckel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 1994;193:637-641.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Guckel, F.5    Lorenz, W.J.6
  • 38
    • 24144469169 scopus 로고    scopus 로고
    • Improved data reconstruction method for GRAPPA
    • Wang Z, Wang J, Detre JA. Improved data reconstruction method for GRAPPA. Magn Reson Med 2005;54:738-742.
    • (2005) Magn Reson Med , vol.54 , pp. 738-742
    • Wang, Z.1    Wang, J.2    Detre, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.