메뉴 건너뛰기




Volumn 12, Issue 3, 2006, Pages 262-268

Confocal microscopy, computer modeling, and quantification of glomerular vascular corrosion casts

Author keywords

Computer modeling; Confocal microscopy; Corrosion casts; Glomerulus; Kidney; Skeletonization

Indexed keywords

ANIMAL; ARTICLE; CAPILLARY; COMPUTER SIMULATION; CONFOCAL MICROSCOPY; GLOMERULUS; IMAGE PROCESSING; KIDNEY CIRCULATION; MALE; METHODOLOGY; RABBIT; ULTRASTRUCTURE; VASCULARIZATION;

EID: 33745668158     PISSN: 14319276     EISSN: 14358115     Source Type: Journal    
DOI: 10.1017/S143192760606034X     Document Type: Article
Times cited : (14)

References (21)
  • 3
    • 0005927355 scopus 로고
    • The vascular pattern of the kidney glomerulus as revealed by plastic reconstruction from serial sections
    • BOYER, C. (1956). The vascular pattern of the kidney glomerulus as revealed by plastic reconstruction from serial sections. Anat Rec 125, 433-441.
    • (1956) Anat Rec , vol.125 , pp. 433-441
    • Boyer, C.1
  • 4
    • 0029555836 scopus 로고
    • Examination of injected specimens by confocal laser scanning microscopy and scanning electron microscopy
    • CASTENHOLZ, A. (1995). Examination of injected specimens by confocal laser scanning microscopy and scanning electron microscopy. Scanning Microsc 9, 1245-1254.
    • (1995) Scanning Microsc , vol.9 , pp. 1245-1254
    • Castenholz, A.1
  • 5
    • 33745651115 scopus 로고    scopus 로고
    • Imaging and volumetric quantitation of vascular corrosion casts with laser scanning confocal microscopy
    • CZYMMEK, K., WAGNER, R., HOSSLER, F.E. & KAO, R. (2001). Imaging and volumetric quantitation of vascular corrosion casts with laser scanning confocal microscopy. Microsc Microanal 6, 562.
    • (2001) Microsc Microanal , vol.6 , pp. 562
    • Czymmek, K.1    Wagner, R.2    Hossler, F.E.3    Kao, R.4
  • 6
    • 0040110526 scopus 로고
    • Some quantitative applications of vascular corrosion casting
    • HOSSLER, F. (1992). Some quantitative applications of vascular corrosion casting. Electron Microsc Soc Am Bull 22, 738-739.
    • (1992) Electron Microsc Soc Am Bull , vol.22 , pp. 738-739
    • Hossler, F.1
  • 7
    • 0040436844 scopus 로고    scopus 로고
    • Vascular corrosion casting: Review of advantages and limitations in the application of some simple quantitative methods
    • HOSSLER, F. & DOUGLAS, J.E. (2001). Vascular corrosion casting: Review of advantages and limitations in the application of some simple quantitative methods. Microsc Microanal 7, 253-264.
    • (2001) Microsc Microanal , vol.7 , pp. 253-264
    • Hossler, F.1    Douglas, J.E.2
  • 8
    • 0022928246 scopus 로고
    • Anatomy and morphometry of myocardial capillaries studied with vascular corrosion casting and scanning electron microscopy: A method for rat heart
    • HOSSLER, F., DOUGLAS, J. & DOUGLAS, L. (1986). Anatomy and morphometry of myocardial capillaries studied with vascular corrosion casting and scanning electron microscopy: A method for rat heart. Scanning Electron Microsc 4, 1469-1475.
    • (1986) Scanning Electron Microsc , vol.4 , pp. 1469-1475
    • Hossler, F.1    Douglas, J.2    Douglas, L.3
  • 9
    • 0026009732 scopus 로고
    • Microvascular architecture of the elastase emphysemic hamster lung
    • HOSSLER, F., DOUGLAS, J., VERGHESE, A. & NEAL, L. (1991). Microvascular architecture of the elastase emphysemic hamster lung. J Electron Microsc Tech 19, 406-418.
    • (1991) J Electron Microsc Tech , vol.19 , pp. 406-418
    • Hossler, F.1    Douglas, J.2    Verghese, A.3    Neal, L.4
  • 10
    • 0030960863 scopus 로고    scopus 로고
    • Three-dimensional modeling of renal glomerular capillary networks
    • KACZMAREK, E. & BECKER, R. (1997). Three-dimensional modeling of renal glomerular capillary networks. Anal Quant Cytol Histol 19, 93-101.
    • (1997) Anal Quant Cytol Histol , vol.19 , pp. 93-101
    • Kaczmarek, E.1    Becker, R.2
  • 11
    • 0024788930 scopus 로고
    • Quantitative measurement from vascular corrosion casts
    • KRATKY, R., ZEINDLER, C., LO, D. & ROACH, M. (1989). Quantitative measurement from vascular corrosion casts. Scanning Microsc 3, 937-943.
    • (1989) Scanning Microsc , vol.3 , pp. 937-943
    • Kratky, R.1    Zeindler, C.2    Lo, D.3    Roach, M.4
  • 12
    • 0034493901 scopus 로고    scopus 로고
    • Length measurements in microvascular corrosion casting: Two dimensional versus three dimensional morphometry
    • MINNICH, B. & LAMETSCHWANDTNER, A. (2000). Length measurements in microvascular corrosion casting: Two dimensional versus three dimensional morphometry. Scanning 22, 173-177.
    • (2000) Scanning , vol.22 , pp. 173-177
    • Minnich, B.1    Lametschwandtner, A.2
  • 13
    • 0032818037 scopus 로고    scopus 로고
    • Three-dimensional morphometry in scanning electron microscopy: A technique for accurate dimensional and angular measurements of microstructures using stereopair digitized images and digital analysis
    • MINNICH, B., LEEB, H., BERNROIDER, E. & LAMETSCHWANDTNER, A. (1999). Three-dimensional morphometry in scanning electron microscopy: A technique for accurate dimensional and angular measurements of microstructures using stereopair digitized images and digital analysis. J Microsc 195, 23-33.
    • (1999) J Microsc , vol.195 , pp. 23-33
    • Minnich, B.1    Leeb, H.2    Bernroider, E.3    Lametschwandtner, A.4
  • 14
    • 0015264310 scopus 로고
    • Vascular arrangement of the rat renal glomerulus: A scanning electron microscopic study of corrosion casts
    • MURAKAMI, T. (1972). Vascular arrangement of the rat renal glomerulus: A scanning electron microscopic study of corrosion casts. Arch Histol Jpn 34, 87-107.
    • (1972) Arch Histol Jpn , vol.34 , pp. 87-107
    • Murakami, T.1
  • 15
    • 0027313263 scopus 로고
    • The number of glomerular capillaries estimated by an unbiased and efficient stereological method
    • NYENGARD, J. & MARCUSSEN, N. (1993). The number of glomerular capillaries estimated by an unbiased and efficient stereological method. J Microsc 171, 27-37.
    • (1993) J Microsc , vol.171 , pp. 27-37
    • Nyengard, J.1    Marcussen, N.2
  • 16
    • 33745665564 scopus 로고    scopus 로고
    • 3D thinning and its applications to medical image processing
    • PALAGYI, K., SORANTIN, E., HALAMI, C. & KUBA, A. (1999). 3D thinning and its applications to medical image processing. TASK Q 3, 397-408.
    • (1999) TASK Q , vol.3 , pp. 397-408
    • Palagyi, K.1    Sorantin, E.2    Halami, C.3    Kuba, A.4
  • 17
    • 0031716153 scopus 로고    scopus 로고
    • Perivascular structures in corrosion casts of the central nervous system: A confocal laser and scanning electron microscope study
    • RODRIGUEZ-BAEZA, A., REINA-DE LA TORRE, F., ORTEGA-SANCHEZ, M. & SAHUQUILLO-BARRIS, J. (1998). Perivascular structures in corrosion casts of the central nervous system: A confocal laser and scanning electron microscope study. Anat Rec 252, 176-184.
    • (1998) Anat Rec , vol.252 , pp. 176-184
    • Rodriguez-Baeza, A.1    Reina-De La Torre, R.L.A.2    Ortega-Sanchez, M.3    Sahuquillo-Barris, J.4
  • 18
    • 0018726709 scopus 로고
    • Glomerular hemodynamics and vascular structure: The pattern and dimensions of a single rat glomerular capillary network reconstructed from ultrathin sections
    • SHEA, S. (1979). Glomerular hemodynamics and vascular structure: The pattern and dimensions of a single rat glomerular capillary network reconstructed from ultrathin sections. Microvase Res 36, 129-143.
    • (1979) Microvase Res , vol.36 , pp. 129-143
    • Shea, S.1
  • 19
    • 0022555290 scopus 로고
    • Technical parameters of plastics (Mercox CL-2B and various methacrylates) using scanning electron microscopy of vascular casts
    • WEIGER, T., LAMETSCHWANDTNER, A. & STOCKMAYER, P. (1986). Technical parameters of plastics (Mercox CL-2B and various methacrylates) using scanning electron microscopy of vascular casts. Scanning Electron Microsc 1, 243-252.
    • (1986) Scanning Electron Microsc , vol.1 , pp. 243-252
    • Weiger, T.1    Lametschwandtner, A.2    Stockmayer, P.3
  • 20
    • 33745677453 scopus 로고    scopus 로고
    • Confocal microscopy, modeling and quantitation of corroded and noncorroded casts of microvascular systems
    • WAGNER, R., CZYMMEK, K. & HOSSLER, F. (2005). Confocal microscopy, modeling and quantitation of corroded and noncorroded casts of microvascular systems. Microsc Microanal 11, 1208-1209.
    • (2005) Microsc Microanal , vol.11 , pp. 1208-1209
    • Wagner, R.1    Czymmek, K.2    Hossler, F.3
  • 21
    • 0034195221 scopus 로고    scopus 로고
    • Gray-scale skeletonization of small vessels in magnetic resonance angiograms
    • YIM, P., SUMMERS, R. & CHOYKE, P. (2000). Gray-scale skeletonization of small vessels in magnetic resonance angiograms. Trans Med Imag 19, 568-576.
    • (2000) Trans Med Imag , vol.19 , pp. 568-576
    • Yim, P.1    Summers, R.2    Choyke, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.