Volumn 9, Issue 2, 2006, Pages 105-113

Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas

Author keywords

Closed loop insulin delivery system; Needle type glucose sensor; Subcutaneous tissue glucose concentration; Wearable artificial endocrine pancreas

Indexed keywords

2 METHACRYLOYLOXYETHYLPHOSPHORYLCHOLINE; 2 METHACRYLOYLOXYETHYLPHOSPHORYLCHOLINE CO N BUTYL METHACRYLATE; COPOLYMER; GLUCOSE; INSULIN; POLYIMIDE; POLYMETHACRYLIC ACID DERIVATIVE; POLYURETHAN; SODIUM CHLORIDE; UNCLASSIFIED DRUG;

EID: 33745655406     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-005-0326-8     Document Type: Article
Times cited : (20)

References (41)
  • 1
    • 0033431643 scopus 로고    scopus 로고
    • The MiniMed continuous glucose monitoring system (CGMS)
    • J Mastrototaro 1999 The MiniMed continuous glucose monitoring system (CGMS) J Pediatr Endocrinol Metab 12 Suppl l3 751 758
    • (1999) J Pediatr Endocrinol Metab , vol.123 , pp. 751-758
    • Mastrototaro, J.1
  • 4
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • K Rebrin GM Steil WP Van Antwerp JJ Mastrototaro 1999 Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring Am J Physiol Endocrinol Metab 277 E561 E571
    • (1999) Am J Physiol Endocrinol Metab , vol.277
    • Rebrin, K.1    Steil, G.M.2    Van Antwerp, W.P.3    Mastrototaro, J.J.4
  • 5
    • 0013011237 scopus 로고    scopus 로고
    • From external to implantable insulin pump: Can we close the loop?
    • E Renard G Costalat J Bringer 2002 From external to implantable insulin pump: can we close the loop? Diabetes Metab 28 2S19 2S25
    • (2002) Diabetes Metab , vol.28
    • Renard, E.1    Costalat, G.2    Bringer, J.3
  • 6
    • 1642452596 scopus 로고    scopus 로고
    • Closed-loop insulin delivery - The path to physiological glucose control
    • GM Steil AE Panteleon K Rebrin 2004 Closed-loop insulin delivery - the path to physiological glucose control Adv Drug Deliv Rev 56 125 144
    • (2004) Adv Drug Deliv Rev , vol.56 , pp. 125-144
    • Steil, G.M.1    Panteleon, A.E.2    Rebrin, K.3
  • 7
    • 0029294501 scopus 로고
    • Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate
    • K Nishida M Sakakida K Ichinose T Uemura M Uehara K Kajiwara T Miyata M Shichiri K Ishihara N Nakabayashi 1995 Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate Med Prog Technol 21 91 103
    • (1995) Med Prog Technol , vol.21 , pp. 91-103
    • Nishida, K.1    Sakakida, M.2    Ichinose, K.3    Uemura, T.4    Uehara, M.5    Kajiwara, K.6    Miyata, T.7    Shichiri, M.8    Ishihara, K.9    Nakabayashi, N.10
  • 9
    • 0028218970 scopus 로고
    • Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method
    • Y Hashiguchi M Sakakida K Nishida T Uemura K Kajiwara M Shichiri 1994 Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method Diabetes Care 17 387 396
    • (1994) Diabetes Care , vol.17 , pp. 387-396
    • Hashiguchi, Y.1    Sakakida, M.2    Nishida, K.3    Uemura, T.4    Kajiwara, K.5    Shichiri, M.6
  • 10
    • 0020402631 scopus 로고
    • Wearable artificial endocrine pancreas with needle-type glucose sensor
    • M Shichiri R Kawamori Y Yamasaki N Hakui H Abe 1982 Wearable artificial endocrine pancreas with needle-type glucose sensor Lancet 2 1129 1131
    • (1982) Lancet , vol.2 , pp. 1129-1131
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3    Hakui, N.4    Abe, H.5
  • 11
    • 0032882086 scopus 로고    scopus 로고
    • Correlation of fingerstick blood glucose measurements with GlucoWatch Biographer glucose results in young subjects with type 1 diabetes
    • SK Garg RO Potts NR Ackerman SJ Fermi JA Tamada HP Chase 1999 Correlation of fingerstick blood glucose measurements with GlucoWatch Biographer glucose results in young subjects with type 1 diabetes Diabetes Care 22 1708 1714
    • (1999) Diabetes Care , vol.22 , pp. 1708-1714
    • Garg, S.K.1    Potts, R.O.2    Ackerman, N.R.3    Fermi, S.J.4    Tamada, J.A.5    Chase, H.P.6
  • 13
    • 0031257640 scopus 로고    scopus 로고
    • Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
    • J Bantle W Thomas 1997 Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid J Lab Clin Med 130 436 441
    • (1997) J Lab Clin Med , vol.130 , pp. 436-441
    • Bantle, J.1    Thomas, W.2
  • 16
    • 0033970025 scopus 로고    scopus 로고
    • Subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration
    • SJ Updike MC Shults BJ Gilligan RK Rhodes 2000 Subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration Diabetes Care 23 208 214
    • (2000) Diabetes Care , vol.23 , pp. 208-214
    • Updike, S.J.1    Shults, M.C.2    Gilligan, B.J.3    Rhodes, R.K.4
  • 18
    • 0034061329 scopus 로고    scopus 로고
    • Transdermal monitoring of glucose and other analytes using ultrasound
    • J Kost S Mitragotri RA Gabbay M Pishko R Langer 2000 Transdermal monitoring of glucose and other analytes using ultrasound Nature Med 6 347 350
    • (2000) Nature Med , vol.6 , pp. 347-350
    • Kost, J.1    Mitragotri, S.2    Gabbay, R.A.3    Pishko, M.4    Langer, R.5
  • 19
    • 0031864724 scopus 로고    scopus 로고
    • Non-invasive continuous glucose monitoring in type 1 diabetic patients with optical glucose sensors
    • L Heinemann G Schmelzeisen-Redeker 1998 Non-invasive continuous glucose monitoring in type 1 diabetic patients with optical glucose sensors Diabetologia 41 848 854
    • (1998) Diabetologia , vol.41 , pp. 848-854
    • Heinemann, L.1    Schmelzeisen-Redeker, G.2
  • 20
    • 0033552348 scopus 로고    scopus 로고
    • In vivo glucose sensing for diabetes management: Progress toward non-invasive monitoring
    • J Pickup L [tmp] McCartney O Rolinski D Birch 1999 In vivo glucose sensing for diabetes management: progress toward non-invasive monitoring Br Med J 319 1289 1293
    • (1999) Br Med J , vol.319 , pp. 1289-1293
    • Pickup, J.1    McCartney, L.2    Rolinski, O.3    Birch, D.4
  • 21
    • 0025689061 scopus 로고
    • Application of chronic intravascular blood glucose sensor in dogs
    • JC Armour JY Luciasno BD [tmp] McKean DA Gough 1990 Application of chronic intravascular blood glucose sensor in dogs Diabetes 39 1519 1526
    • (1990) Diabetes , vol.39 , pp. 1519-1526
    • Armour, J.C.1    Luciasno, J.Y.2    McKean, B.D.3    Gough, D.A.4
  • 22
    • 0023676677 scopus 로고
    • Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum
    • LC Clark Jr LK Noyes RB Spokane R Sudan ML Miller 1988 Long-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum Meth Enzymol 137 68 89
    • (1988) Meth Enzymol , vol.137 , pp. 68-89
    • Clark Jr., L.C.1    Noyes, L.K.2    Spokane, R.B.3    Sudan, R.4    Miller, M.L.5
  • 25
    • 0023580011 scopus 로고
    • Assessment of subcutaneous glucose concentration: Validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs
    • U Fischer R Ertle P Abel K Rebrin E Brunstein H Hahn von Dorsche EJ Freyse 1987 Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs Diabetologia 30 940 945
    • (1987) Diabetologia , vol.30 , pp. 940-945
    • Fischer, U.1    Ertle, R.2    Abel, P.3    Rebrin, K.4    Brunstein, E.5    Hahn Von Dorsche, H.6    Freyse, E.J.7
  • 26
    • 0018068244 scopus 로고
    • Suction blister fluid as a model for interstitial fluid in rats
    • MJ Herfst H Van Rees 1978 Suction blister fluid as a model for interstitial fluid in rats Arch Dermatol Res 263 325 334
    • (1978) Arch Dermatol Res , vol.263 , pp. 325-334
    • Herfst, M.J.1    Van Rees, H.2
  • 28
    • 0026740343 scopus 로고
    • Dynamics of the cellular and humoral components of the inflammatory response elicited in skin blisters in humans
    • DB Kuhns E DeCarlo DM Hawk JI Gallin 1992 Dynamics of the cellular and humoral components of the inflammatory response elicited in skin blisters in humans J Clin Invest 89 1734 1740
    • (1992) J Clin Invest , vol.89 , pp. 1734-1740
    • Kuhns, D.B.1    Decarlo, E.2    Hawk, D.M.3    Gallin, J.I.4
  • 29
    • 0028097682 scopus 로고
    • Dynamics of glucose production and uptake are more closely related to insulin in hindlimb lymph than in thoracic duct lymph
    • RA Poulin GM Steil DM Moore M Ader RN Bergman 1994 Dynamics of glucose production and uptake are more closely related to insulin in hindlimb lymph than in thoracic duct lymph Diabetes 43 180 190
    • (1994) Diabetes , vol.43 , pp. 180-190
    • Poulin, R.A.1    Steil, G.M.2    Moore, D.M.3    Ader, M.4    Bergman, R.N.5
  • 31
    • 0027230940 scopus 로고
    • Glucose concentration in subcutaneous extracellular space
    • F Schmidt WJ Sluiter AJM Schoonen 1993 Glucose concentration in subcutaneous extracellular space Diabetes Care 16 695 700
    • (1993) Diabetes Care , vol.16 , pp. 695-700
    • Schmidt, F.1    Sluiter, W.J.2    Schoonen, A.J.M.3
  • 32
    • 0031278033 scopus 로고    scopus 로고
    • Methodological aspects of glucose monitoring with a slow continuous subcutaneous and intravenous ultrafiltration system in rats
    • WA Kaptein RHA Kemper MHJ Ruiters K Venema RG Tiessen J Korf 1997 Methodological aspects of glucose monitoring with a slow continuous subcutaneous and intravenous ultrafiltration system in rats Biosensors Bioelectronics 12 967 976
    • (1997) Biosensors Bioelectronics , vol.12 , pp. 967-976
    • Kaptein, W.A.1    Kemper, R.H.A.2    Ruiters, M.H.J.3    Venema, K.4    Tiessen, R.G.5    Korf, J.6
  • 33
    • 0035715516 scopus 로고    scopus 로고
    • Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers
    • KJ Wientjes AJ Schoonen 2001 Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers Int J Artif Organs 24 884 889
    • (2001) Int J Artif Organs , vol.24 , pp. 884-889
    • Wientjes, K.J.1    Schoonen, A.J.2
  • 35
    • 0024446904 scopus 로고
    • Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man
    • J Bolinder E Hagstrom U Ungerstedt P Arner 1989 Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man Scand J Clin Lab Invest 49 465 474
    • (1989) Scand J Clin Lab Invest , vol.49 , pp. 465-474
    • Bolinder, J.1    Hagstrom, E.2    Ungerstedt, U.3    Arner, P.4
  • 36
    • 0025214042 scopus 로고
    • In vivo subcutaneous adipose tissue glucose kinetics after glucose ingestion in obesity and fasting
    • E Hagstrom P Arner P Engfeldt S Rossner J Bolinder 1990 In vivo subcutaneous adipose tissue glucose kinetics after glucose ingestion in obesity and fasting Scand J Clin Lab Invest 50 129 136
    • (1990) Scand J Clin Lab Invest , vol.50 , pp. 129-136
    • Hagstrom, E.1    Arner, P.2    Engfeldt, P.3    Rossner, S.4    Bolinder, J.5
  • 38
    • 0033759474 scopus 로고    scopus 로고
    • Can interstitial glucose assessment replace blood glucose measurements?
    • K Rebrin GM Steil 2000 Can interstitial glucose assessment replace blood glucose measurements? Diabetes Tech Ther 2 461 472
    • (2000) Diabetes Tech Ther , vol.2 , pp. 461-472
    • Rebrin, K.1    Steil, G.M.2
  • 39
    • 0021704147 scopus 로고
    • A mathematical insulin-secretion model and its validation in isolated rat pancreatic islets perifusion
    • M Nomura M Shichiri R Kawamori Y Yamasaki N Iwama H Abe 1984 A mathematical insulin-secretion model and its validation in isolated rat pancreatic islets perifusion Comput Biomed Res 17 570 579
    • (1984) Comput Biomed Res , vol.17 , pp. 570-579
    • Nomura, M.1    Shichiri, M.2    Kawamori, R.3    Yamasaki, Y.4    Iwama, N.5    Abe, H.6
  • 40
    • 0347624612 scopus 로고    scopus 로고
    • Modeling beta-cell insulin secretion - Implications for closed-loop glucose homeostasis
    • GM Steil K Rebrin R Janowski C Darwin MF Saad 2003 Modeling beta-cell insulin secretion - implications for closed-loop glucose homeostasis Diabetes Technol Ther 5 953 964
    • (2003) Diabetes Technol Ther , vol.5 , pp. 953-964
    • Steil, G.M.1    Rebrin, K.2    Janowski, R.3    Darwin, C.4    Saad, M.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.