메뉴 건너뛰기




Volumn 55, Issue 2, 2006, Pages 167-171

Safety and usefulness of a novel eMotion® electric mesh nebulizer in children with asthma

Author keywords

Asthma; Beta2 agonist; Children; eMotion ; Mesh nebulizer

Indexed keywords

PROCATEROL;

EID: 33745648340     PISSN: 13238930     EISSN: 14401592     Source Type: Journal    
DOI: 10.2332/allergolint.55.167     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 13544253826 scopus 로고    scopus 로고
    • Device selection and outcomes of aerosol therapy: Evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and Immunology
    • Dolovich MB, Ahrens RC, Hess DR et al. Device selection and outcomes of aerosol therapy: Evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and Immunology. Chest 2005;127:335-371.
    • (2005) Chest , vol.127 , pp. 335-371
    • Dolovich, M.B.1    Ahrens, R.C.2    Hess, D.R.3
  • 2
    • 0036046546 scopus 로고    scopus 로고
    • Holding chambers versus nebulisers for beta-agonist treatment of acute asthma
    • CD000052
    • Cates CJ, Rowe BH, Bara A. Holding chambers versus nebulisers for beta-agonist treatment of acute asthma. Cochrane Database Syst. Rev. 2002:CD000052.
    • (2002) Cochrane Database Syst. Rev.
    • Cates, C.J.1    Rowe, B.H.2    Bara, A.3
  • 4
    • 0036885621 scopus 로고    scopus 로고
    • Nebulizers that use a vibrating mesh or plate with multiple apertures to generate aerosol
    • Dhand R. Nebulizers that use a vibrating mesh or plate with multiple apertures to generate aerosol. Respir. Care 2002;47:1406-1416.
    • (2002) Respir. Care , vol.47 , pp. 1406-1416
    • Dhand, R.1
  • 5
    • 11144290017 scopus 로고    scopus 로고
    • Dose-response to salbutamol via a novel palm sized nebuliser (Aerodose Inhaler), conventional nebuliser (Pari LC Plus) and metered dose inhaler (Ventolin Evohaler) in moderate to severe asthmatics
    • Lipworth BJ, Sims EJ, Taylor K, Cockburn W, Fishman R Dose-response to salbutamol via a novel palm sized nebuliser (Aerodose Inhaler), conventional nebuliser (Pari LC Plus) and metered dose inhaler (Ventolin Evohaler) in moderate to severe asthmatics. Br. J. Clin. Pharmacol. 2005;59:5-13.
    • (2005) Br. J. Clin. Pharmacol. , vol.59 , pp. 5-13
    • Lipworth, B.J.1    Sims, E.J.2    Taylor, K.3    Cockburn, W.4    Fishman, R.5
  • 6
    • 0025360861 scopus 로고
    • Measurement of bronchial hyperreactivity in infants and preschool children using a new method
    • Murakami G, Igarashi T, Adachi Y et al. Measurement of bronchial hyperreactivity in infants and preschool children using a new method. Ann. Allergy 1990;64:383-387.
    • (1990) Ann. Allergy , vol.64 , pp. 383-387
    • Murakami, G.1    Igarashi, T.2    Adachi, Y.3
  • 7
    • 0028851093 scopus 로고
    • Metered-dose inhalers with spacers vs nebulizers for pediatric asthma
    • Chou KJ, Cunningham SJ, Crain EF. Metered-dose inhalers with spacers vs nebulizers for pediatric asthma. Arch. Pediatr. Adolesc. Med. 1995;149:201-205.
    • (1995) Arch. Pediatr. Adolesc. Med. , vol.149 , pp. 201-205
    • Chou, K.J.1    Cunningham, S.J.2    Crain, E.F.3
  • 8
    • 0027214272 scopus 로고
    • Efficacy of albuterol administered by nebulizer versus spacer device in children with acute asthma
    • Kerem E, Levison H, Schuh S et al. Efficacy of albuterol administered by nebulizer versus spacer device in children with acute asthma. J. Pediatr. 1993;123:313-317.
    • (1993) J. Pediatr. , vol.123 , pp. 313-317
    • Kerem, E.1    Levison, H.2    Schuh, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.