메뉴 건너뛰기




Volumn 53, Issue 9, 2006, Pages 111-121

Application of a membrane bioreactor for the treatment of low loaded domestic wastewater for water re-use

Author keywords

Alternate cycles; Low C N ratio; Low loaded wastewater; Membrane bioreactor; Micropollutants; Water re use

Indexed keywords

ACTIVATED SLUDGE PROCESS; BIOCHEMICAL OXYGEN DEMAND; BIOLOGICAL MEMBRANES; BIOLOGICAL WATER TREATMENT; CHEMICAL OXYGEN DEMAND; EFFLUENTS; NITROGEN; PHOSPHORUS; WASTEWATER TREATMENT;

EID: 33745637669     PISSN: 02731223     EISSN: None     Source Type: Book Series    
DOI: 10.2166/wst.2006.280     Document Type: Article
Times cited : (17)

References (13)
  • 1
    • 24544437351 scopus 로고    scopus 로고
    • Metodo e dispositivo di controllo di un processo di trattamento biologico, a cicli alternati, di acque reflue
    • Italian Patent N° NR99A00
    • Battistoni, P. and Chemitec (1999). Metodo e dispositivo di controllo di un processo di trattamento biologico, a cicli alternati, di acque reflue. Italian Patent N° NR99A00.
    • (1999)
    • Battistoni, P.1    Chemitec2
  • 2
    • 0037193640 scopus 로고    scopus 로고
    • Addition of an external carbon source to enhance nitrogen biological removal in the treatment of liquid industrial wastes
    • Battistoni, P., Boccadoro, R., Innocenti, L. and Bolzonella, D. (2002). Addition of an external carbon source to enhance nitrogen biological removal in the treatment of liquid industrial wastes. Ind. Eng. Che. Res., 41(11), 2805-2811.
    • (2002) Ind. Eng. Che. Res. , vol.41 , Issue.11 , pp. 2805-2811
    • Battistoni, P.1    Boccadoro, R.2    Innocenti, L.3    Bolzonella, D.4
  • 3
    • 0347269032 scopus 로고    scopus 로고
    • An alternate oxic-anoxic process automatically controlled: Theory and practice in a real treatment plant network
    • Battistoni, P., Boccadoro, R., Bolzonella, D. and Marinelli, M. (2003a). An alternate oxic-anoxic process automatically controlled: theory and practice in a real treatment plant network. Wat. Sci. Technol., 48(11-12), 337-344.
    • (2003) Wat. Sci. Technol. , vol.48 , Issue.11-12 , pp. 337-344
    • Battistoni, P.1    Boccadoro, R.2    Bolzonella, D.3    Marinelli, M.4
  • 4
    • 0037419843 scopus 로고    scopus 로고
    • An automatically controlled alternate oxic-anoxic, process. A feasible way to perform high nitrogen biological removal also during wet weather periods
    • Battistoni, P., De Angelis, A., Boccadoro, R. and Bolzonella, D. (2003b). An automatically controlled alternate oxic-anoxic, process. A feasible way to perform high nitrogen biological removal also during wet weather periods. Ind. Eng. Chem. Res., 42(3), 509-515.
    • (2003) Ind. Eng. Chem. Res. , vol.42 , Issue.3 , pp. 509-515
    • Battistoni, P.1    De Angelis, A.2    Boccadoro, R.3    Bolzonella, D.4
  • 5
    • 0141789750 scopus 로고    scopus 로고
    • Membrane bioreactor processes: A must for the wastewater treatment plants of the lagoon of Venice
    • Cecchi, F., Innocenti, L., Bolzonella, D. and Pavan, P. (2003). Membrane bioreactor processes: a must for the wastewater treatment plants of the lagoon of Venice. Annali di Chimica, 93, 381-388.
    • (2003) Annali Di Chimica , vol.93 , pp. 381-388
    • Cecchi, F.1    Innocenti, L.2    Bolzonella, D.3    Pavan, P.4
  • 6
    • 0025429293 scopus 로고
    • Use of ORP for monitoring and control of aerobic sludge digestion
    • Craig, Q., Peddie, C., Donald, S., Mavinic, C. and Jenkins, D. (1990). Use of ORP for monitoring and control of aerobic sludge digestion. J. Envir. Engrg. ASCE, 116(3), 461-447.
    • (1990) J. Envir. Engrg. ASCE , vol.116 , Issue.3 , pp. 447-461
    • Craig, Q.1    Peddie, C.2    Donald, S.3    Mavinic, C.4    Jenkins, D.5
  • 7
    • 0036215237 scopus 로고    scopus 로고
    • Characteristic of grey wastewater
    • Eriksonn, A. and Henze, L. (2002). Characteristic of grey wastewater. Urban Water, 4(1), 85-104.
    • (2002) Urban Water , vol.4 , Issue.1 , pp. 85-104
    • Eriksonn, A.1    Henze, L.2
  • 8
    • 0029848745 scopus 로고    scopus 로고
    • Modified platinum electrodes: Electrochemical characteristics and behaviour in activated sludge
    • Heduit, A., Quino, I., Stadmuller, D. and Thévenot, D.R. (1996). Modified platinum electrodes: electrochemical characteristics and behaviour in activated sludge. Wat. Sci. Technol., 34(3/4), 143-150.
    • (1996) Wat. Sci. Technol. , vol.34 , Issue.3-4 , pp. 143-150
    • Heduit, A.1    Quino, I.2    Stadmuller, D.3    Thévenot, D.R.4
  • 9
    • 0038388197 scopus 로고    scopus 로고
    • Modelling biological nutrient removal activated sludge systems - A review
    • Hu, Z.R., Wentzel, M.C. and Ekama, G.A. (2003). Modelling biological nutrient removal activated sludge systems - a review. Water Res., 37(14), 3430-3444.
    • (2003) Water Res. , vol.37 , Issue.14 , pp. 3430-3444
    • Hu, Z.R.1    Wentzel, M.C.2    Ekama, G.A.3
  • 10
    • 0037056702 scopus 로고    scopus 로고
    • Effect of sludge age on the performance of a membrane bioreactor. Influence on nutrient and metals removal
    • Innocenti, L., Bolzonella, D., Pavan, P. and Cecchi, F. (2002). Effect of sludge age on the performance of a membrane bioreactor. Influence on nutrient and metals removal. Desalination, 146(1-3), 467-474.
    • (2002) Desalination , vol.146 , Issue.1-3 , pp. 467-474
    • Innocenti, L.1    Bolzonella, D.2    Pavan, P.3    Cecchi, F.4
  • 11
    • 0027473633 scopus 로고
    • A rapid physical chemical method for the determination of readily biodegradable soluble COD in municipal wastewater
    • Mamais, D., Jenkins, D. and Pitt, P. (1993). A rapid physical chemical method for the determination of readily biodegradable soluble COD in municipal wastewater. Wat, Res., 27, 195-197.
    • (1993) Wat. Res. , vol.27 , pp. 195-197
    • Mamais, D.1    Jenkins, D.2    Pitt, P.3
  • 12
    • 0029956138 scopus 로고    scopus 로고
    • Real-time control of nitrogen removal using three ORP bending-points: Signification, control strategy and results
    • Plisson-Saune, S., Capdeville, B., Mauret, M., Deguin, A. and Baptiste, P. (1996). Real-time control of nitrogen removal using three ORP bending-points: signification, control strategy and results. Wat. Sci. Technol., 33(1).
    • (1996) Wat. Sci. Technol. , vol.33 , Issue.1
    • Plisson-Saune, S.1    Capdeville, B.2    Mauret, M.3    Deguin, A.4    Baptiste, P.5
  • 13
    • 4444311355 scopus 로고    scopus 로고
    • Operational performance of a submerged membrane bioreactor for reclamation of bath wastewater
    • Riu Liu, Xia Huang, Lvjun Chen, Xianghua Wen, and Yi Qian, (2005). Operational performance of a submerged membrane bioreactor for reclamation of bath wastewater. Proc. Biochem, 40(1), 125-130.
    • (2005) Proc. Biochem , vol.40 , Issue.1 , pp. 125-130
    • Liu, R.1    Huang, X.2    Chen, L.3    Wen, X.4    Qian, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.