메뉴 건너뛰기




Volumn 21, Issue 3, 2006, Pages 1068-1073

Acousto-optical PD detection for transformers

Author keywords

Acoustic sensor; Partial discharge; Transformer

Indexed keywords

ACOUSTIC FIELD MEASUREMENT; ELECTRIC TRANSFORMER TESTING; ELECTRIC VARIABLES MEASUREMENT; PARTIAL DISCHARGES; SIGNAL TO NOISE RATIO;

EID: 33745604263     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2005.861242     Document Type: Article
Times cited : (98)

References (35)
  • 1
    • 0025383298 scopus 로고
    • "Detection of partial discharges in electrical apparatus"
    • Feb
    • R. Bartnikas, "Detection of partial discharges in electrical apparatus," IEEE Trans. Electr. Insul., vol. 25, no. 1, pp. 111-124, Feb. 1990.
    • (1990) IEEE Trans. Electr. Insul. , vol.25 , Issue.1 , pp. 111-124
    • Bartnikas, R.1
  • 2
    • 0029356842 scopus 로고
    • "A generalized approach to partial discharge modeling"
    • Aug
    • L. Niemeyer, "A generalized approach to partial discharge modeling," IEEE Trans. Dielectr. Electr. Insul., vol. 2, no. 4, pp. 510-528, Aug. 1995.
    • (1995) IEEE Trans. Dielectr. Electr. Insul. , vol.2 , Issue.4 , pp. 510-528
    • Niemeyer, L.1
  • 3
    • 0027634116 scopus 로고
    • "The early history of partial discharge research"
    • Jan./Feb
    • D. H. Nattras, "The early history of partial discharge research," IEEE Electr. Insul. Mag., vol. 9, no. 1, pp. 27-31, Jan./Feb. 1993.
    • (1993) IEEE Electr. Insul. Mag. , vol.9 , Issue.1 , pp. 27-31
    • Nattras, D.H.1
  • 7
    • 0036564344 scopus 로고    scopus 로고
    • "A review of faults detectable by gas-in-oil analysis in transformers"
    • May/Jun
    • M. Duval, "A review of faults detectable by gas-in-oil analysis in transformers," IEEE Electr. Insul. Mag., vol. 18, no. 3, May/Jun. 2002.
    • (2002) IEEE Electr. Insul. Mag. , vol.18 , Issue.3
    • Duval, M.1
  • 8
    • 0024768426 scopus 로고
    • "Dissolved gas analysis: It can save your transformer"
    • Jan./Feb
    • M. Duval, "Dissolved gas analysis: It can save your transformer," IEEE Electr. Insul. Mag., vol. 5, no. 1, pp. 22-27, Jan./Feb. 1989.
    • (1989) IEEE Electr. Insul. Mag. , vol.5 , Issue.1 , pp. 22-27
    • Duval, M.1
  • 9
    • 0038005389 scopus 로고    scopus 로고
    • "New techniques for dissolved gas-in-oil analysis"
    • Mar./Apr
    • M. Duval, "New techniques for dissolved gas-in-oil analysis," IEEE Electr. Insul. Mag., vol. 19, no. 2, pp. 6-15, Mar./Apr. 2003.
    • (2003) IEEE Electr. Insul. Mag. , vol.19 , Issue.2 , pp. 6-15
    • Duval, M.1
  • 10
    • 0025519323 scopus 로고
    • "Partial discharge - Part III: Cavity-induced PD in solid dielectrics"
    • Jan./Feb
    • S. A. Boggs, "Partial discharge - Part III: Cavity-induced PD in solid dielectrics," IEEE Electr. Insul. Mag., vol. 6, no. 1, pp. 11-20, Jan./Feb. 1990.
    • (1990) IEEE Electr. Insul. Mag. , vol.6 , Issue.1 , pp. 11-20
    • Boggs, S.A.1
  • 11
    • 0003078783 scopus 로고
    • "Detection and location of coronas in oil-immersed transformer with corona detector"
    • H. Ogihara, "Detection and location of coronas in oil-immersed transformer with corona detector," Electr. Eng. Jpn., vol. 84, pp. 12-22, 1964.
    • (1964) Electr. Eng. Jpn. , vol.84 , pp. 12-22
    • Ogihara, H.1
  • 12
    • 0020721075 scopus 로고
    • "Incipient fault identification through neutral RF monitoring of large rotating machines"
    • PAS-102
    • J. E. Timperley, "Incipient fault identification through neutral RF monitoring of large rotating machines," IEEE Trans. Power App. Syst., vol. PAS-102, pp. 693-698, 1983.
    • (1983) IEEE Trans. Power App. Syst. , pp. 693-698
    • Timperley, J.E.1
  • 13
    • 0012505145 scopus 로고    scopus 로고
    • "A system for continuous on-line monitoring and localization of partial discharges in power generators"
    • Montreal, Canada
    • A. Kheirmand, M. Leijon, K. Hurtig, and H. Väliviita, "A system for continuous on-line monitoring and localization of partial discharges in power generators," in Proc. ISH' 97, vol. 4, Montreal, Canada, 1997, p. 315.
    • (1997) Proc. ISH' 97 , vol.4 , pp. 315
    • Kheirmand, A.1    Leijon, M.2    Hurtig, K.3    Väliviita, H.4
  • 14
    • 33745633559 scopus 로고    scopus 로고
    • "The research on PD detection using pulse current method and ultrasound method"
    • L. Yaqiao, "The research on PD detection using pulse current method and ultrasound method," Power Capac., no. 2, pp. 31-35, 1996.
    • (1996) Power Capac. , Issue.2 , pp. 31-35
    • Yaqiao, L.1
  • 15
    • 0038737566 scopus 로고    scopus 로고
    • "Progress of insulation on-line monitoring and fault diagnosis techniques for high voltage power equipment in China"
    • G. Zhang, G. Wu, and D.-H. Park, "Progress of insulation on-line monitoring and fault diagnosis techniques for high voltage power equipment in China," KIEE Int. Trans. Electrophs. and Applic., vol. 12C, no. 1, pp. 1-14, 2002.
    • (2002) KIEE Int. Trans. Electrophs. and Applic. , vol.12 C , Issue.1 , pp. 1-14
    • Zhang, G.1    Wu, G.2    Park, D.-H.3
  • 16
    • 33745628700 scopus 로고
    • "Early fault detection in electrical machines by on-line RF monitoring"
    • Vienna, Austria
    • A. Wichmann, P. Grünewald, and J. Weidner, "Early fault detection in electrical machines by on-line RF monitoring," in Cigré Symp., Vienna, Austria, 1987, pp. 05-87.
    • (1987) Cigré Symp. , pp. 05-87
    • Wichmann, A.1    Grünewald, P.2    Weidner, J.3
  • 18
    • 17644409075 scopus 로고    scopus 로고
    • "Partial discharge monitoring for power transformers using UHF sensors. Part 1: Sensors and signal interpretation"
    • Mar./Apr
    • M. D. Judd, L. Yang, and I. B. B. Hunter, "Partial discharge monitoring for power transformers using UHF sensors. Part 1: Sensors and signal interpretation," IEEE Electr. Insul. Mag., vol. 21, no. 1, p. 5, Mar./Apr. 2005.
    • (2005) IEEE Electr. Insul. Mag. , vol.21 , Issue.1 , pp. 5
    • Judd, M.D.1    Yang, L.2    Hunter, I.B.B.3
  • 19
    • 17644409075 scopus 로고    scopus 로고
    • "Partial discharge monitoring for power transformer using UHF sensors. Part 2: Field experience"
    • Mar./Apr
    • M. D. Judd, L. Yang, and I. B. B. Hunter, "Partial discharge monitoring for power transformer using UHF sensors. Part 2: Field experience," IEEE Electr. Insul. Mag., vol. 21, no. 2, Mar./Apr. 2005.
    • (2005) IEEE Electr. Insul. Mag. , vol.21 , Issue.2
    • Judd, M.D.1    Yang, L.2    Hunter, I.B.B.3
  • 20
    • 0021376510 scopus 로고
    • "Partial discharge automatic monitor for oil-filled power transformer"
    • PAS-104
    • H. Kawada, M. Honda, T. Inoue, and T. Amemiya, "Partial discharge automatic monitor for oil-filled power transformer," IEEE Trans. Power App. Syst., vol. PAS-104, pp. 422-428, 1984.
    • (1984) IEEE Trans. Power App. Syst. , pp. 422-428
    • Kawada, H.1    Honda, M.2    Inoue, T.3    Amemiya, T.4
  • 21
    • 0022013976 scopus 로고
    • "Acoustical technology applications in electrical insulation and dielectrics"
    • Feb
    • R. T. Harold, "Acoustical technology applications in electrical insulation and dielectrics," IEEE Trans. Electr. Insul., vol. 20, no. EI-1, pp. 1-3, Feb. 1985.
    • (1985) IEEE Trans. Electr. Insul. , vol.20 , Issue.EI-1 , pp. 1-3
    • Harold, R.T.1
  • 23
    • 84945715370 scopus 로고
    • "Partial discharge - Part XIV: Acoustic partial discharge detection - Practical application"
    • Jan./Feb
    • L. Lundgaard, "Partial discharge - Part XIV: Acoustic partial discharge detection - Practical application," IEEE Electr. Insul. Mag., vol. 8, no. 1, pp. 34-43, Jan./Feb. 1992.
    • (1992) IEEE Electr. Insul. Mag. , vol.8 , Issue.1 , pp. 34-43
    • Lundgaard, L.1
  • 24
    • 0026887276 scopus 로고
    • "Partial discharge - Part XIII: Acoustic partial discharge detection - Fundamental considerations"
    • Jan./Feb
    • L. Lundgaard, "Partial discharge - Part XIII: Acoustic partial discharge detection - Fundamental considerations," IEEE Electr. Insul. Mag., vol. 8, no. 1, pp. 25-31, Jan./Feb. 1992.
    • (1992) IEEE Electr. Insul. Mag. , vol.8 , Issue.1 , pp. 25-31
    • Lundgaard, L.1
  • 26
    • 0018443425 scopus 로고
    • "Acoustic waveguide for sensing and locating electrical discharges in high voltage power transformers and other apparatus"
    • PAS-98
    • R. T. Harold, "Acoustic waveguide for sensing and locating electrical discharges in high voltage power transformers and other apparatus," IEEE Trans. Power App. Syst., vol. PAS-98, no. 2, pp. 449-457, 1979.
    • (1979) IEEE Trans. Power App. Syst. , Issue.2 , pp. 449-457
    • Harold, R.T.1
  • 27
    • 33745622337 scopus 로고
    • "PD-source identification in solids"
    • Baltimore, MD
    • M. Leijon, L. Ming, and T. Bengtsson, "PD-source identification in solids," in IEEE Seminarian, Baltimore, MD, 1992, pp. 15-418.
    • (1992) IEEE Seminarian , pp. 15-418
    • Leijon, M.1    Ming, L.2    Bengtsson, T.3
  • 28
    • 33745627008 scopus 로고    scopus 로고
    • "Partial Discharge Detection and Localization in High Voltage Transformers using an Optical Acoustic Sensor"
    • Master, Virginia Polytechnic Inst. and State Univ
    • A. K. Lazarevich, "Partial Discharge Detection and Localization in High Voltage Transformers using an Optical Acoustic Sensor," Master, Virginia Polytechnic Inst. and State Univ., 2003.
    • (2003)
    • Lazarevich, A.K.1
  • 30
    • 3843104563 scopus 로고    scopus 로고
    • "Optical fiber acoustic sensor for sensing and locating partial discharges in high-voltage oil-filled power transformers"
    • Gold Coast, Australia
    • Z. Zhao and M. Demokan, "Optical fiber acoustic sensor for sensing and locating partial discharges in high-voltage oil-filled power transformers," in Proc. 21st Australia Conf. Optical Fiber Technology, Gold Coast, Australia, 1996.
    • (1996) Proc. 21st Australia Conf. Optical Fiber Technology
    • Zhao, Z.1    Demokan, M.2
  • 32
    • 0030144654 scopus 로고    scopus 로고
    • "Split-spectrum intensity-based optical fiber sensors for measurement of microdisplacement, strain and pressure"
    • A. Wang, M. S. Miller, K. A. Murphy, and R. O. Claus, "Split-spectrum intensity-based optical fiber sensors for measurement of microdisplacement, strain and pressure," Appl. Opt., vol. 35, pp. 2595-2601, 1996.
    • (1996) Appl. Opt. , vol.35 , pp. 2595-2601
    • Wang, A.1    Miller, M.S.2    Murphy, K.A.3    Claus, R.O.4
  • 33
    • 58849093585 scopus 로고    scopus 로고
    • "Self-calibrated interferometric_intensity-based optical fiber sensors"
    • Proc. SPIE, B. O. Nnaji and A. Wang, Eds
    • J. Wang, W. Zhao, H. Xiao, and A. Wang, "Self-calibrated interferometric_intensity-based optical fiber sensors," in Sensors and Contr. for Advanced Manufact., vol. 3201, Proc. SPIE, B. O. Nnaji and A. Wang, Eds., 1998, pp. 20-26.
    • (1998) Sensors and Contr. for Advanced Manufact. , vol.3201 , pp. 20-26
    • Wang, J.1    Zhao, W.2    Xiao, H.3    Wang, A.4
  • 34
    • 0042973927 scopus 로고    scopus 로고
    • "Fiber Fabry-Perot sensors for detection of partial discharges in power transformers"
    • B. Yu, J. Deng, H. Xiao, and A. Wang, "Fiber Fabry-Perot sensors for detection of partial discharges in power transformers," Appl. Opt., vol. 43, pp. 3241-3250, 2003.
    • (2003) Appl. Opt. , vol.43 , pp. 3241-3250
    • Yu, B.1    Deng, J.2    Xiao, H.3    Wang, A.4
  • 35
    • 15744362048 scopus 로고    scopus 로고
    • "An ultra-sensitive optical MEMS sensor for partial discharge detection"
    • Mar
    • X. Wang, B. Li, Z. Xiao, H. T. Roman, O. L. Russo, K. Chin, and K. R. Farmer, "An ultra-sensitive optical MEMS sensor for partial discharge detection," J. Micromech. Microeng., vol. 15, no. 3, pp. 521-527, Mar. 2005.
    • (2005) J. Micromech. Microeng. , vol.15 , Issue.3 , pp. 521-527
    • Wang, X.1    Li, B.2    Xiao, Z.3    Roman, H.T.4    Russo, O.L.5    Chin, K.6    Farmer, K.R.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.