메뉴 건너뛰기




Volumn 57, Issue 1, 2006, Pages 80-83

A new technique for microvascular anastomosis: Eversion with 3 horizontal mattress sutures

Author keywords

3 horizontal mattress sutures; Microsurgery; Microvascular surgery; Vascular anastomosis method; Vessel anastomosis

Indexed keywords

ANASTOMOSIS; ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; CONTROLLED STUDY; END TO END ANASTOMOSIS; FEMALE; HISTOPATHOLOGY; INFLAMMATION; INTIMA; MALE; MICROSCOPY; MICROSURGERY; MICROVASCULATURE; NONHUMAN; OPERATION DURATION; PRIORITY JOURNAL; RAT; SURGICAL TECHNIQUE; TUNICA MEDIA;

EID: 33745585111     PISSN: 01487043     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.sap.0000203999.59856.c5     Document Type: Article
Times cited : (10)

References (20)
  • 1
    • 0031963117 scopus 로고    scopus 로고
    • Experience with the continous suture microvascular anastomosis in 200 consecutive free flaps
    • Cordeiro PG, Santamaria E. Experience with the continous suture microvascular anastomosis in 200 consecutive free flaps. Ann Plast Surg. 1998;40:1-6.
    • (1998) Ann Plast Surg , vol.40 , pp. 1-6
    • Cordeiro, P.G.1    Santamaria, E.2
  • 2
    • 0028283598 scopus 로고
    • A comparison of different suture techniques for microvascular anastomosis
    • Schlechter B, Guyuron B. A comparison of different suture techniques for microvascular anastomosis. Ann Plast Surg. 1994;33:28-31.
    • (1994) Ann Plast Surg , vol.33 , pp. 28-31
    • Schlechter, B.1    Guyuron, B.2
  • 3
    • 0035145222 scopus 로고    scopus 로고
    • Eversion with four sutures: An easy, fast and reliable technique for microvascular anastomosis
    • Turan T, Özçelik D, Kuran I, et al. Eversion with four sutures: an easy, fast and reliable technique for microvascular anastomosis. Plast Reconst Surg. 2001;107:463-470.
    • (2001) Plast Reconst Surg , vol.107 , pp. 463-470
    • Turan, T.1    Özçelik, D.2    Kuran, I.3
  • 4
    • 0018225192 scopus 로고
    • A new and easier way to anastomose microvessels: An experimental study in rats
    • Lauritzen C. A new and easier way to anastomose microvessels: an experimental study in rats. Scand J Plast Reconstr Surg. 1978;12:291-294.
    • (1978) Scand J Plast Reconstr Surg , vol.12 , pp. 291-294
    • Lauritzen, C.1
  • 6
    • 0030789186 scopus 로고    scopus 로고
    • End on side microvasculer anastomosis: An experimental study
    • Tellioǧlu T. End on side microvasculer anastomosis: an experimental study. Ann Plast Surg. 1997;39:137-140.
    • (1997) Ann Plast Surg , vol.39 , pp. 137-140
    • Tellioǧlu, T.1
  • 7
    • 0036077692 scopus 로고    scopus 로고
    • Increasing the flow output by Y-shaped microvascular anastomosis
    • Boeckx W, Lorenzi FD, Hulst VD. Increasing the flow output by Y-shaped microvascular anastomosis. J Reconstr Microsurg. 2002;18:381-386.
    • (2002) J Reconstr Microsurg , vol.18 , pp. 381-386
    • Boeckx, W.1    Lorenzi, F.D.2    Hulst, V.D.3
  • 8
    • 10744223695 scopus 로고    scopus 로고
    • Use of longitudinal invaginating matrix sutures in microarterial sleeve anastomoses
    • Güneren E, Odaci E, Yildiz L, et al. Use of longitudinal invaginating matrix sutures in microarterial sleeve anastomoses. Scand J Plast Reconstr Surg. 2004;38:1-4.
    • (2004) Scand J Plast Reconstr Surg , vol.38 , pp. 1-4
    • Güneren, E.1    Odaci, E.2    Yildiz, L.3
  • 9
    • 0041971040 scopus 로고    scopus 로고
    • Management of significant venous discrepancy with microvascular venous coupler
    • Sullivan SK, Dellacroce F, Allen R. Management of significant venous discrepancy with microvascular venous coupler. J Reconstr Microsurg. 2003;19:377-380.
    • (2003) J Reconstr Microsurg , vol.19 , pp. 377-380
    • Sullivan, S.K.1    Dellacroce, F.2    Allen, R.3
  • 10
    • 24044511821 scopus 로고    scopus 로고
    • Open guide suture technique for safe microvascular anastomosis
    • Ozkan O, Ozgentas HE. Open guide suture technique for safe microvascular anastomosis. Ann Plast Surg. 2005;55:289-291.
    • (2005) Ann Plast Surg , vol.55 , pp. 289-291
    • Ozkan, O.1    Ozgentas, H.E.2
  • 11
    • 0022538763 scopus 로고
    • End-to-end versus end-to-side microvascular anastomosis patency in experimental venous repairs
    • Bas L, May JW Jr, Handren J, et al. End-to-end versus end-to-side microvascular anastomosis patency in experimental venous repairs. Plast Reconstr Surg. 1986;77:442-450.
    • (1986) Plast Reconstr Surg , vol.77 , pp. 442-450
    • Bas, L.1    May Jr., J.W.2    Handren, J.3
  • 13
    • 0026093123 scopus 로고
    • Microvascular anastomosis: Vascular cuff technique
    • Robbins TH. Microvascular anastomosis: vascular cuff technique. Plast Reconst Surg. 1991;87:567-568.
    • (1991) Plast Reconst Surg , vol.87 , pp. 567-568
    • Robbins, T.H.1
  • 14
    • 0023929170 scopus 로고
    • Comparative study of artery cuff and fat wrap in microvascular anstomosis in the rat
    • Hung LK, Au KK, Ho YF. Comparative study of artery cuff and fat wrap in microvascular anstomosis in the rat. Br J Plast Surg. 1988;41:278-283.
    • (1988) Br J Plast Surg , vol.41 , pp. 278-283
    • Hung, L.K.1    Au, K.K.2    Ho, Y.F.3
  • 15
    • 0029983567 scopus 로고    scopus 로고
    • Microvascular anastomoses: A comparative study of fibrinogen adhesive and interrupted suture techniques
    • Bowen C, Leach D, Crosby N, et al. Microvascular anastomoses: a comparative study of fibrinogen adhesive and interrupted suture techniques. Plast Reconst Surg. 1996;97:792-800.
    • (1996) Plast Reconst Surg , vol.97 , pp. 792-800
    • Bowen, C.1    Leach, D.2    Crosby, N.3
  • 16
    • 0024576011 scopus 로고
    • Microvascular anastomosis using polyethylene glycol 4000 and fibrin glue
    • Kamiji T, Maeda M, Matsumoto K, et al. Microvascular anastomosis using polyethylene glycol 4000 and fibrin glue. Br J Plast Surg. 1989;42:54-58.
    • (1989) Br J Plast Surg , vol.42 , pp. 54-58
    • Kamiji, T.1    Maeda, M.2    Matsumoto, K.3
  • 17
    • 0034122915 scopus 로고    scopus 로고
    • Microvascular anastomosis 2-octyl cyanoacrylate in the rat femoral artery
    • Hall WW, Wrye SW, Banducci DR, et al. Microvascular anastomosis 2-octyl cyanoacrylate in the rat femoral artery. Ann Plast Surg. 2000;44:508-511.
    • (2000) Ann Plast Surg , vol.44 , pp. 508-511
    • Hall, W.W.1    Wrye, S.W.2    Banducci, D.R.3
  • 18
    • 0035025462 scopus 로고    scopus 로고
    • 2-Octylciyanoacrylate-assisted microvascular anastomosis: Comparison with a conventional suture technique in the rat femoral arteries
    • Ang ESW, Tan KC, Tan LHC, et al. 2-Octylciyanoacrylate-assisted microvascular anastomosis: comparison with a conventional suture technique in the rat femoral arteries. J Reconstr Microsurg. 2001;17:193-201.
    • (2001) J Reconstr Microsurg , vol.17 , pp. 193-201
    • Ang, E.S.W.1    Tan, K.C.2    Tan, L.H.C.3
  • 19
    • 2342450058 scopus 로고    scopus 로고
    • Microvascular anastomosis using cyanoacrylate adhesives
    • Kim BY, Choi BH, Huh JY, et al. Microvascular anastomosis using cyanoacrylate adhesives. J Reconstr Microsurg. 2004;20:317-321.
    • (2004) J Reconstr Microsurg , vol.20 , pp. 317-321
    • Kim, B.Y.1    Choi, B.H.2    Huh, J.Y.3
  • 20
    • 0018828862 scopus 로고
    • Expansion of smaller vessel diameter by fish mouth incision in microvascular anastomosis with marked discrepancy
    • Harashina T, Irigaray A. Expansion of smaller vessel diameter by fish mouth incision in microvascular anastomosis with marked discrepancy. Plast Reconstr Surg. 1980;65:502-503.
    • (1980) Plast Reconstr Surg , vol.65 , pp. 502-503
    • Harashina, T.1    Irigaray, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.